Code of Federal Regulations (alpha)

CFR /  Title 10  /  Part 429  /  Sec. 429.51 Commercial pre-rinse spray valves.

(a) Sampling plan for selection of units for testing. (1) The requirements of Sec. 429.11 are applicable to commercial pre-rinse spray valves; and

(1) The requirements of Sec. 429.11 are applicable to commercial pre-rinse spray valves; and

(2) For each basic model of commercial pre-rinse spray valves selected for testing, a sample of sufficient size shall be randomly selected and tested to ensure that--

(i) Any represented value of water consumption or other measure of water consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:

(A) The mean of the sample, where:

[GRAPHIC] [TIFF OMITTED] TR07MR11.122

Or,

(B) The upper 95 percent confidence limit (UCL) of the true mean divided by 1.10, where:[GRAPHIC] [TIFF OMITTED] TR02MY11.084 and

(ii) Any represented value of the water efficiency or other measure of water consumption of a basic model for which consumers would favor higher values shall be less than or equal to the lower of:

(A) The mean of the sample, where: [GRAPHIC] [TIFF OMITTED] TR07MR11.124 Or,

(B) The lower 95 percent confidence limit (LCL) of the true mean divided by 0.90, where:[GRAPHIC] [TIFF OMITTED] TR02MY11.085

(b) Certification reports. (1) The requirements of Sec. 429.12 are applicable to commercial pre-rinse spray valves; and

(1) The requirements of Sec. 429.12 are applicable to commercial pre-rinse spray valves; and

(2) Pursuant to Sec. 429.12(b)(13), a certification report shall include the following public product-specific information: The maximum flow rate in gallons per minute (gpm), rounded to the nearest 0.1 gallon. [76 FR 12451, Mar. 7, 2011; 76 FR 24779, May 2, 2011, as amended at 78 FR 62986, Oct. 23, 2013]