Code of Federal Regulations (alpha)

CFR /  Title 14  /  Part 25  /  Sec. 25.371 Gyroscopic loads.

The structure supporting any engine or auxiliary power unit must be designed for the loads, including gyroscopic loads, arising from the conditions specified in Sec. Sec. 25.331, 25.341, 25.349, 25.351, 25.473, 25.479, and 25.481, with the engine or auxiliary power unit at the maximum rotating speed appropriate to the condition. For the purposes of compliance with this paragraph, the pitch maneuver in Sec. 25.331(c)(1) must be carried out until the positive limit maneuvering load factor (point A2 in Sec. 25.333(b)) is reached.