CFR /  Title 30  /  Part 7  /  Sec. 7.102 Exhaust gas cooling efficiency test.

(a) Test procedures. (1) Follow the procedures specified in Sec. 7.101(a).

(1) Follow the procedures specified in Sec. 7.101(a).

(2) Install a temperature measuring device to measure the exhaust gas temperature at discharge from the exhaust conditioner. The temperature measuring device shall be accurate to 4 [deg]F (2 [deg]C).

(3) Determine the exhaust gas temperature at discharge from the exhaust conditioner before the exhaust gas is diluted with air.

(b) Acceptable performance. (1) The exhaust gas temperature at discharge from a wet exhaust conditioner before the exhaust gas is diluted with air shall not exceed 170 [deg]F (76 [deg]C).

(1) The exhaust gas temperature at discharge from a wet exhaust conditioner before the exhaust gas is diluted with air shall not exceed 170 [deg]F (76 [deg]C).

(2) The exhaust gas temperature at discharge from a dry exhaust conditioner before the gas is diluted with air shall not exceed 302 [deg]F (150 [deg]C).