Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 1065  /  Sec. 1065.644 Vacuum-decay leak rate.

This section describes how to calculate the leak rate of a vacuum-decay leak verification, which is described in Sec. 1065.345(e). Use the following equation to calculate the leak rate nleak, and compare it to the criterion specified in Sec. 1065.345(e): [GRAPHIC] [TIFF OMITTED] TR28AP14.036 Where: Vvac = geometric volume of the vacuum-side of the sampling

system.R = molar gas constant.p2 = vacuum-side absolute pressure at time t2.T2 = vacuum-side absolute temperature at time t2.p1 = vacuum-side absolute pressure at time t1.T1 = vacuum-side absolute temperature at time t1.t2 = time at completion of vacuum-decay leak verification

test.t1 = time at start of vacuum-decay leak verification test. Example: Vvac = 2.0000 L = 0.00200 m\3\R = 8.314472 J/(mol [middot] K) = 8.314472 (m\2\ [middot] kg)/(s\2\

[middot] mol [middot] K)p2 = 50.600 kPa = 50600 Pa = 50600 kg/(m [middot] s\2\)T2 = 293.15 Kp1 = 25.300 kPa = 25300 Pa = 25300 kg/(m [middot] s\2\)T1 = 293.15 Kt2 = 10:57:35 a.m.t1 = 10:56:25 a.m.[GRAPHIC] [TIFF OMITTED] TR28AP14.037 [GRAPHIC] [TIFF OMITTED] TR28AP14.038 [79 FR 23795, Apr. 28, 2014]