Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 147  /  Sec. 147.1153 Existing Class I, II (except enhanced recovery and

Maximum injection pressure. The owner or operator shall limit injection pressure to the lesser of:

(a) A value which will not exceed the operating requirements of Sec. 144.28(f)(3) (i) or (ii) as applicable; or

(b) A value for well head pressure calculated by using the following formula: Pm=(0.800-0.433 Sg)d where: Pm=injection pressure at the well head in pounds per square inchSg=specific gravity of injected fluid (unitless)d=injection depth in feet.