(a) The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart:

(1) Any Alaskan scallop processing facility located in population or processing centers including but not limited to Anchorage, Cordova, Juneau, Ketchikan, Kodiak, and Petersburg shall meet the following limitations: ------------------------------------------------------------------------

Effluent limitations

-----------------------------

Average of daily

Effluent characteristic Maximum values for 30

for any 1 consecutive days

day shall not

exceed--------------------------------------------------------------------------

Metric units (kg/kkg of

product)

-------------TSS....................................... 5.7 1.4Oil and grease............................ 7.3 0.23pH........................................ (\1\) (\1\)

-------------

English units (lb/1,000 lb

of product)

-------------TSS....................................... 5.7 1.4Oil and grease............................ 7.3 0.23pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

(2) Any Alaskan scallop processing facility not covered under Sec. 408.295(a) (1) shall meet the following limitations: No pollutants may be discharged which exceed 1.27 cm (0.5 inch) in any dimension.