Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 409  /  Sec. 409.22 Effluent limitations guidelines representing the degreepracticable control technology currently available.

Except as provided in Secs. 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) Any crystalline cane sugar refinery discharging both barometric condenser cooling water and other process waters shall meet the following limitations. The BOD5 limitation is determined by the addition of the net BOD5 attributed to the barometric condenser cooling water to that amount of BOD5 attributed to the treated process water. The TSS limitation is that amount of TSS attributed to the treated process water. Where the barometric condenser cooling water and process water streams are mixed and impossible to measure separately prior to discharge, the values should be considered net. ------------------------------------------------------------------------

Effluent limitations

-----------------------------

Average of daily

Effluent characteristic Maximum values for 30

for any 1 consecutive days

day shall not

exceed--------------------------------------------------------------------------

Metric units (kilograms per

1,000 kg of melt)

-------------BOD5...................................... 1.19 0.43TSS....................................... .27 0.09pH........................................ (\1\) (\1\)

-------------

English units (pounds per

ton of melt)

-------------BOD5...................................... 2.38 0.86TSS....................................... .54 .18pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

(b) Any crystalline cane sugar refinery discharging barometric condenser cooling water only should be required to achieve the following net limitations: ------------------------------------------------------------------------

Effluent limitations

-----------------------------

Average of daily

Effluent characteristic Maximum values for 30

for any 1 consecutive days

day shall not

exceed--------------------------------------------------------------------------

Metric units (kilograms per

1,000 kg of melt)

-------------BOD5...................................... 1.02 0.34

-------------

English units (pounds per

ton of melt)

-------------BOD5...................................... 2.04 0.68------------------------------------------------------------------------ [39 FR 10524, Mar. 20, 1974, as amended at 60 FR 33949, June 29, 1995] Sec. 409.23 [Reserved]