CFR /  Title 40  /  Part 409  /  Sec. 409.82 Effluent limitations guidelines representing the degreepracticable control technology currently available.

Except as provided in Secs. 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) Any cane sugar factory continuously discharging both barometric condenser cooling water and other process waste waters shall meet the following limitations. The BOD5 limitation is determined by the addition of the net BOD5 attributable to the barometric condenser cooling water to that amount of BOD5 attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water. ------------------------------------------------------------------------

Effluent limitations

-----------------------------

Average of daily

Effluent characteristic Maximum values for 30

for any 1 consecutive days

day shall not

exceed--------------------------------------------------------------------------

Metric units (kg/kkg of

gross cane)

-------------BOD5...................................... 1.14 0.63TSS....................................... 1.41 0.47pH........................................ (\1\) (\1\)

-------------

English units (lb/1,000 lb

of gross cane)

-------------BOD5...................................... 1.14 0.63TSS....................................... 1.41 0.47pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

(b) Any cane sugar factory employing waste stabilization where all or a portion of the waste water discharge is stored for the entire grinding season shall meet the following limitations. The BOD5 limitation is determined by the addition of the net BOD5 attributable to the barometric condenser cooling water to that amount of BOD5 attributable to the treated process waste water. The TSS limitation is that amount of TSS attributable to the treated process waste water, excluding barometric condenser cooling water. ------------------------------------------------------------------------

Effluent limitations, the total

of the daily values for the

Effluent characteristic entire discharge period shall

not exceed--------------------------------------------------------------------------

Metric units (kg/kkg of gross

cane)

---------------------------------BOD5.................................. 0.63.TSS................................... 0.47.pH.................................... Within the range 6.0 to 9.0.

---------------------------------

English units (lb/1,000 lb of

gross cane)

---------------------------------BOD5.................................. 0.63.TSS................................... 0.47.pH.................................... Within the range 6.0 to 9.0.------------------------------------------------------------------------ (Secs. 301, 304 (b) and (c), 306 (b) and (c), 307 (c) and (d) of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317(c) and 1326(c)), 86 Stat. 816 et seq., Pub. L. 92-500) [40 FR 8504, Feb. 27, 1975, as amended at 60 FR 33950, June 29, 1995]