Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 421  /  Sec. 421.22 Effluent limitations guidelines representing the degreepracticable control

technology currently available.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable technology currently available (BPT): ------------------------------------------------------------------------

Maximum for

Pollutant or pollutant property Maximum for monthly

any 1 day average------------------------------------------------------------------------

Metric units--kg/kkg of

product

English units--lbs/

thousand lbs of product

--------------Fluoride...................................... 2.0 1.0Total Suspended solids........................ 3.0 1.5pH............................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range of 6 to 9 at all times. [49 FR 8792, Mar. 8, 1984; 49 FR 29794, July 24, 1984]