Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 424  /  Sec. 424.15 Standards of performance for new sources.

The following standards of performance establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a new source subject to the provisions of this subpart: ------------------------------------------------------------------------

Effluent limitations

-----------------------------

Average of daily

Effluent characteristic Maximum values for 30

for any 1 consecutive days

day shall not

exceed--------------------------------------------------------------------------

Metric units (kg/Mwh)

-------------TSS....................................... 0.024 0.012Chromium total............................ .0008 .0004Chromium VI............................... .00008 .00004Manganese total........................... .008 .0039pH........................................ (\1\) (\1\)

-------------

English units (lb/Mwh)

-------------TSS....................................... .052 .026Chromium total............................ .0017 .0009Chromium VI............................... .0002 .0001Manganese total........................... .017 .0086pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.