Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 426  /  Sec. 426.113 Effluent limitations guidelines representing the degree oftechnology economically achievable.

The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable. These limitations are applicable to the abrasive polishing and acid polishing waste water streams. ------------------------------------------------------------------------

Effluent limitations

-----------------------------

Average of daily

Effluent characteristic Maximum values for 30

for any 1 consecutive days

day shall not

exceed--------------------------------------------------------------------------

Metric units (g/kkg of

furnace pull)

-----------------------------Fluoride.................................. 120.0 60.0Lead...................................... 0.9 0.45

-----------------------------

English units (lb/1,000 lb

of furnace pull)

-----------------------------Fluoride.................................. 0.12 0.06Lead...................................... 0.0009 0.00045------------------------------------------------------------------------ [44 FR 50747, Aug. 29, 1979] Sec. 426.114 [Reserved]