Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 426  /  Sec. 426.72 Effluent limitations guidelines representing the degree ofcontrol technology currently available.

Except as provided in Secs. 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): ------------------------------------------------------------------------

Effluent limitations

-----------------------------

Average of daily

Effluent characteristic Maximum values for 30

for any 1 consecutive days

day shall not

exceed--------------------------------------------------------------------------

Metric units (q/sq m of

product)

-----------------------------TSS....................................... 4.40 4.40Oil....................................... 1.76 1.76Phosphorus................................ 1.07 1.07pH........................................ (\1\) (\1\)

-----------------------------

English units (lb/1,000 sq

ft of product)

-----------------------------TSS....................................... 0.90 0.90Oil....................................... 0.36 .36Phosphorus................................ 0.22 .22pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0. [39 FR 5714, Feb. 14, 1974, as amended at 60 FR 33959, June 29, 1995]