CFR /  Title 40  /  Part 445  /  Sec. 445.21 Effluent limitations attainable by the application of the

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations which represent the application of BPT:

Effluent Limitations------------------------------------------------------------------------

Maximum

Regulated parameter Maximum monthly avg.

daily \1\ \1\------------------------------------------------------------------------BOD......................................... 140 37TSS......................................... 88 27Ammonia (as N).............................. 10 4.9[alpha]-Terpineol........................... 0.033 0.016Benzoic acid................................ 0.12 0.071p-Cresol.................................... 0.025 0.014Phenol...................................... 0.026 0.015Zinc........................................ 0.20 0.11