Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 463  /  Sec. 463.14 New source performance standards.

(a) NSPS for bis(2-ethylhexyl) phthalate are reserved.

(b) Any new source subject to this subpart must achieve performance standards (i.e., mass of pollutant discharged), which are calculated by multiplying the average process water usage flow rate for the contact cooling and heating water processes at a new source times the following pollutant concentrations:

Subpart A

[Contact cooling and heating water]------------------------------------------------------------------------

Concentration used to calculate NSPS-------------------------------------------------------------------------

Maximum for

Pollutant or pollutant property any 1 day

(mg/l)------------------------------------------------------------------------BOD5....................................................... 26Oil and grease............................................. 29TSS........................................................ 19pH......................................................... (\1\)------------------------------------------------------------------------\1\ Within the range of 6.0 to 9.0 at all times. The permit authority will obtain the average process water usage flow rate for the new source contact cooling and heating water processes from the permittee.