Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 463  /  Sec. 463.22 Effluent limitations guidelines representing the degree ofcontrol technology currently available.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the effluent limitations guidelines (i.e., mass of pollutant discharged) representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available, which are calculated by multiplying the average process water usage flow rate for the cleaning water processes at a point source times the following pollutant concentrations:

Subpart B

[Cleaning water]------------------------------------------------------------------------

Concentration used to calculate BPT effluent limitations-------------------------------------------------------------------------

Maximum for

Maximum for monthly

Pollutant or pollutant property any 1 day average (mg/

(mg/l) l)------------------------------------------------------------------------BOD5.......................................... 49 22Oil and grease................................ 71 17TSS........................................... 117 36pH............................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range of 6.0 to 9.0 at all times. The permit authority will obtain the average process water usage flow rate for the cleaning water processes from the permittee.