Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 503  /  Sec. 503.23 Pollutant limits (other than domestic septage).

(a) Active sewage sludge unit without a liner and leachate collection system.

(1) Except as provided in Sec. 503.23 (a)(2) and (b), the concentration of each pollutant listed in Table 1 of Sec. 503.23 in sewage sludge placed on an active sewage sludge unit shall not exceed the concentration for the pollutant in Table 1 of Sec. 503.23.

Table 1 of Sec. 503.23--Pollutant Concentrations--Active Sewage Sludge

Unit Without a Liner and Leachate Collection------------------------------------------------------------------------

Concentration

(milligrams

Pollutant per kilograms

\1\)------------------------------------------------------------------------Arsenic................................................. 73Chromium................................................ 600Nickel.................................................. 420------------------------------------------------------------------------\1\ Dry weight basis.

(2) Except as provided in Sec. 503.23(b), the concentration of each pollutant listed in Table 1 of Sec. 503.23 in sewage sludge placed on an active sewage sludge unit whose boundary is less than 150 meters from the property line of the surface disposal site shall not exceed the concentration determined using the following procedure.

(i) The actual distance from the active sewage sludge unit boundary to the property line of the surface disposal site shall be determined.

(ii) The concentration of each pollutant listed in Table 2 of Sec. 503.23 in the sewage sludge shall not exceed the concentration in Table 2 of Sec. 503.23 that corresponds to the actual distance in Sec. 503.23(a)(2)(i).

Table 2 of Sec. 503.23--Pollutant Concentrations--Active Sewage Sludge

Unit Without a Liner and Leachate Collection System That Has a Unit

Boundary to Property Line Distance Less Than 150 Meters------------------------------------------------------------------------

Unit boundary to property line Pollutant concentration \1\------------------------------------------------------------------------

Arsenic Chromium Nickel

Distance (meters) (mg/kg) (mg/kg) (mg/kg)------------------------------------------------------------------------0 to less than 25........................ 30 200 21025 to less than 50....................... 34 220 24050 to less than 75....................... 39 260 27075 to less than 100...................... 46 300 320100 to less than 125..................... 53 360 390125 to less than 150..................... 62 450 420------------------------------------------------------------------------\1\ Dry weight basis.

(b) Active sewage sludge unit without a liner and leachate collection system--site-specific limits.

(1) At the time of permit application, the owner/operator of a surface disposal site may request site-specific pollutant limits in accordance with Sec. 503.23(b)(2) for an active sewage sludge unit without a liner and leachate collection system when the existing values for site parameters specified by the permitting authority are different from the values for those parameters used to develop the pollutant limits in Table 1 of Sec. 503.23 and when the permitting authority determines that site-specific pollutant limits are appropriate for the active sewage sludge unit.

(2) The concentration of each pollutant listed in Table 1 of Sec. 503.23 in sewage sludge placed on an active sewage sludge unit without a liner and leachate collection system shall not exceed either the concentration for the pollutant determined during a site-specific assessment, as specified by the permitting authority, or the existing concentration of the pollutant in the sewage sludge, whichever is lower.