Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 63  /  Sec. 63.3370 How do I demonstrate compliance with the emission standards?

(a) A summary of how you must demonstrate compliance follows: ------------------------------------------------------------------------If you choose to demonstrate Then you must

(1) Use of ``as-purchased'' (i) Each coating Follow the

compliant coating materials. material used at an procedures set out

existing affected in Sec.

source does not 63.3370(b).

exceed 0.04 kg

organic HAP per kg

coating material,

and each coating

material used at a

new affected source

does not exceed

0.016 kg organic

HAP per kg coating

material as-

purchased; or.

(ii) Each coating Follow the

material used at an procedures set out

existing affected in Sec.

source does not 63.3370(b).

exceed 0.2 kg

organic HAP per kg

coating solids, and

each coating

material used at a

new affected source

does not exceed

0.08 kg organic HAP

per kg coating

solids as-purchased.(2) Use of ``as-applied'' (i) Each coating Follow the

compliant coating materials. material used at an procedures set out

existing affected in Sec.

source does not 63.3370(c)(1). Use

exceed 0.04 kg either Equation 1a

organic HAP per kg or b of Sec.

coating material, 63.3370 to

and each coating determine

material used at a compliance with

new affected source Sec.

does not exceed 63.3320(b)(2) in

0.016 kg organic accordance with

HAP per kg coating Sec.

material as- 63.3370(c)(5)(i).

applied; or.

(ii) Each coating Follow the

material used at an procedures set out

existing affected in Sec.

source does not 63.3370(c)(2). Use

exceed 0.2 kg Equations 2 and 3

organic HAP per kg of Sec. 63.3370

coating solids, and to determine

each coating compliance with

material used at a Sec.

new affected source 63.3320(b)(3) in

does not exceed accordance with

0.08 kg organic HAP Sec.

per kg coating 63.3370(c)(5)(i).

solids as-applied;

or.

(iii) Monthly Follow the

average of all procedures set out

coating materials in Sec.

used at an existing 63.3370(c)(3). Use

affected source Equation 4 of Sec.

does not exceed 63.3370 to

0.04 kg organic HAP determine

per kg coating compliance with

material, and Sec.

monthly average of 63.3320(b)(2) in

all coating accordance with

materials used at a Sec.

new affected source 63.3370(c)(5)(ii).

does not exceed

0.016 kg organic

HAP per kg coating

material as-applied

on a monthly

average basis; or.

(iv) Monthly average Follow the

of all coating procedures set out

materials used at in Sec.

an existing 63.3370(c)(4). Use

affected source Equation 5 of Sec.

does not exceed 0.2 63.3370 to

kg organic HAP per determine

kg coating solids, compliance with

and monthly average Sec.

of all coating 63.3320(b)(3) in

materials used at a accordance with

new affected source Sec.

does not exceed 63.3370(c)(5)(ii).

0.08 kg organic HAP

per kg coating

solids as-applied

on a monthly

average basis.(3) Tracking total monthly Total monthly Follow the

organic HAP applied. organic HAP applied procedures set out

does not exceed the in Sec.

calculated limit 63.3370(d). Show

based on emission that total monthly

limitations. HAP applied

(Equation 6 of Sec.

63.3370) is less

than the calculated

equivalent

allowable organic

HAP (Equation 13a

or b of Sec.

63.3370).(4) Use of a capture system (i) Overall organic Follow the

and control device. HAP control procedures set out

efficiency is equal in Sec.

to 95 percent at an 63.3370(e) to

existing affected determine

source and 98 compliance with

percent at a new Sec.

affected source on 63.3320(b)(1)

a monthly basis; or according to Sec.

oxidizer outlet 63.3370(i) if using

organic HAP a solvent recovery

concentration is no device, or Sec.

greater than 20 63.3370(j) if using

ppmv by compound a control device

and capture and CPMS, or Sec.

efficiency is 100 63.3370(k) if using

percent; or an oxidizer.

operating

parameters are

continuously

monitored; or.

(ii) Overall organic Follow the

HAP emission rate procedures set out

does not exceed 0.2 in Sec.

kg organic HAP per 63.3370(f) to

kg coating solids determine

for an existing compliance with

affected source or Sec.

0.08 kg organic HAP 63.3320(b)(3)

per kg coating according to Sec.

solids for a new 63.3370(i) if using

affected source on a solvent recovery

a monthly average device, or Sec.

as-applied basis;. 63.3370(k) if using

an oxidizer.

(iii) Overall Follow the

organic HAP procedures set out

emission rate does in Sec.

not exceed 0.04 kg 63.3370(g) to

organic HAP per kg determine

coating material compliance with

for an existing Sec.

affected source or 63.3320(b)(2)

0.016 kg organic according to Sec.

HAP per kg coating 63.3370(i) if using

material for a new a solvent recovery

affected source on device, or Sec.

a monthly average 63.3370(k) if using

as-applied basis; an oxidizer.

or.

(iv) Overall organic Follow the

HAP emission rate procedures set out

does not exceed the in Sec.

calculated limit 63.3370(h). Show

based on emission that the monthly

limitations. organic HAP

emission rate is

less than the

calculated

equivalent

allowable organic

HAP emission rate

(Equation 13a or b

of Sec. 63.3370).

Calculate the

monthly organic HAP

emission rate

according to Sec.

63.3370(i) if using

a solvent recovery

device, or Sec.

63.3370(k) if using

an oxidizer.(5) Use of multiple capture (i) Overall organic Follow the

and/or control devices. HAP control procedures set out

efficiency is equal in Sec.

to 95 percent at an 63.3370(e) to

existing affected determine

source and 98 compliance with

percent at a new Sec.

affected source on 63.3320(b)(1)

a monthly basis; or. according to Sec.

63.3370(e)(1) or

(2).

(ii) Average Follow the

equivalent organic procedures set out

HAP emission rate in Sec.

does not exceed 0.2 63.3370(f) to

kg organic HAP per determine

kg coating solids compliance with

for an existing Sec.

affected source or 63.3320(b)(3)

0.08 kg organic HAP according to Sec.

per kg coating 63.3370(n).

solids for a new

affected source on

a monthly average

as-applied basis;

or.

(iii) Average Follow the

equivalent organic procedures set out

HAP emission rate in Sec.

does not exceed 63.3370(g) to

0.04 kg organic HAP determine

per kg coating compliance with

material for an Sec.

existing affected 63.3320(b)(2)

source or 0.016 kg according to Sec.

organic HAP per kg 63.3370(n).

coating material

for a new affected

source on a monthly

average as-applied

basis; or.

(iv) Average Follow the

equivalent organic procedures set out

HAP emission rate in Sec.

does not exceed the 63.3370(h). Show

calculated limit that the monthly

based on emission organic HAP

limitations. emission rate is

less than the

calculated

equivalent

allowable organic

HAP emission rate

(Equation 13a or b

of Sec. 63.3370)

according to Sec.

63.3370(n).(6) Use of a combination of (i) Average Follow the

compliant coatings and equivalent organic procedures set out

control devices. HAP emission rate in Sec.

does not exceed 0.2 63.3370(f) to

kg organic HAP per determine

kg coating solids compliance with

for an existing Sec.

affected source or 63.3320(b)(3)

0.08 kg organic HAP according to Sec.

per kg coating 63.3370(n).

solids for a new

affected source on

a monthly average

as-applied basis;

or.

(ii) Average Follow the

equivalent organic procedures set out

HAP emission rate in Sec.

does not exceed 63.3370(g) to

0.04 kg organic HAP determine

per kg coating compliance with

material for an Sec.

existing affected 63.3320(b)(2)

source or 0.016 kg according to Sec.

organic HAP per kg 63.3370(n).

coating material

for a new affected

source on a monthly

average as-applied

basis; or.

(iii) Average Follow the

equivalent organic procedures set out

HAP emission rate in Sec.

does not exceed the 63.3370(h). Show

calculated limit that the monthly

based on emission organic HAP

limitations. emission rate is

less than the

calculated

equivalent

allowable organic

HAP emission rate

(Equation 13a or b

of Sec. 63.3370)

according to Sec.

63.3370(n).------------------------------------------------------------------------

(b) As-purchased ``compliant'' coating materials. (1) If you comply by using coating materials that individually meet the emission standards in Sec. 63.3320(b)(2) or (3), you must demonstrate that each coating material applied during the month at an existing affected source contains no more than 0.04 mass fraction organic HAP or 0.2 kg organic HAP per kg coating solids, and that each coating material applied during the month at a new affected source contains no more than 0.016 mass fraction organic HAP or 0.08 kg organic HAP per kg coating solids on an as-purchased basis as determined in accordance with Sec. 63.3360(c).

(1) If you comply by using coating materials that individually meet the emission standards in Sec. 63.3320(b)(2) or (3), you must demonstrate that each coating material applied during the month at an existing affected source contains no more than 0.04 mass fraction organic HAP or 0.2 kg organic HAP per kg coating solids, and that each coating material applied during the month at a new affected source contains no more than 0.016 mass fraction organic HAP or 0.08 kg organic HAP per kg coating solids on an as-purchased basis as determined in accordance with Sec. 63.3360(c).

(2) You are in compliance with emission standards in Sec. 63.3320(b)(2) and (3) if each coating material applied at an existing affected source is applied as-purchased and contains no more than 0.04 kg organic HAP per kg coating material or 0.2 kg organic HAP per kg coating solids, and each coating material applied at a new affected source is applied as-purchased and contains no more than 0.016 kg organic HAP per kg coating material or 0.08 kg organic HAP per kg coating solids.

(c) As-applied ``compliant'' coating materials. If you comply by using coating materials that meet the emission standards in Sec. 63.3320(b)(2) or (3) as-applied, you must demonstrate compliance by following one of the procedures in paragraphs (c)(1) through (4) of this section. Compliance is determined in accordance with paragraph (c)(5) of this section.

(1) Each coating material as-applied meets the mass fraction of coating material standard (Sec. 63.3320(b)(2)). You must demonstrate that each coating material applied at an existing affected source during the month contains no more than 0.04 kg organic HAP per kg coating material applied, and each coating material applied at a new affected source contains no more than 0.016 kg organic HAP per kg coating material applied as determined in accordance with paragraphs (c)(1)(i) and (ii) of this section. You must calculate the as-applied organic HAP content of as-purchased coating materials which are reduced, thinned, or diluted prior to application.

(i) Determine the organic HAP content or volatile organic content of each coating material applied on an as-purchased basis in accordance with Sec. 63.3360(c).

(ii) Calculate the as-applied organic HAP content of each coating material using Equation 1a of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.027 Where: Cahi = Monthly average, as-applied, organic HAP content of

coating material, i, expressed as a mass fraction, kg/kg.Chi = Organic HAP content of coating material, i, as-

purchased, expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = number of different materials added to the coating material.Chij = Organic HAP content of material, j, added to as-

purchased coating material, i, expressed as a mass fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg. or calculate the as-applied volatile organic content of each coating material using Equation 1b of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.028 Where: Cavi = Monthly average, as-applied, volatile organic content

of coating material, i, expressed as a mass fraction, kg/kg.Cvi = Volatile organic content of coating material, i,

expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material.Cvij = Volatile organic content of material, j, added to as-

purchased coating material, i, expressed as a mass fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.

(2) Each coating material as-applied meets the mass fraction of coating solids standard (Sec. 63.3320(b)(3)). You must demonstrate that each coating material applied at an existing affected source contains no more than 0.20 kg of organic HAP per kg of coating solids applied and each coating material applied at a new affected source contains no more than 0.08 kg of organic HAP per kg of coating solids applied. You must demonstrate compliance in accordance with paragraphs (c)(2)(i) and (ii) of this section.

(i) Determine the as-applied coating solids content of each coating material following the procedure in Sec. 63.3360(d). You must calculate the as-applied coating solids content of coating materials which are reduced, thinned, or diluted prior to application, using Equation 2 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.029 Where: Csi = Coating solids content of coating material, i,

expressed as a mass fraction, kg/kg. Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material.Csij = Coating solids content of material, j, added to as-

purchased coating material, i, expressed as a mass-fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.

(ii) Calculate the as-applied organic HAP to coating solids ratio using Equation 3 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.030 Where: Hsi = As-applied, organic HAP to coating solids ratio of

coating material, i.Cahi = Monthly average, as-applied, organic HAP content of

coating material, i, expressed as a mass fraction, kg/kg.Casi = Monthly average, as-applied, coating solids content of

coating material, i, expressed as a mass fraction, kg/kg.

(3) Monthly average organic HAP content of all coating materials as-applied is less than the mass percent limit (Sec. 63.3320(b)(2)). Demonstrate that the monthly average as-applied organic HAP content of all coating materials applied at an existing affected source is less than 0.04 kg organic HAP per kg of coating material applied, and all coating materials applied at a new affected source are less than 0.016 kg organic HAP per kg of coating material applied, as determined by Equation 4 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.031 Where: HL = Monthly average, as-applied, organic HAP content of all

coating materials applied, expressed as kg organic HAP per kg

of coating material applied, kg/kg.p = Number of different coating materials applied in a month.Chi = Organic HAP content of coating material, i, as-

purchased, expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material.Chij = Organic HAP content of material, j, added to as-

purchased coating material, i, expressed as a mass fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.Mvret = Mass of volatile matter retained in the coated web

after curing or drying, or otherwise not emitted to the

atmosphere, kg. The value of this term will be zero in all

cases except where you choose to take into account the

volatile matter retained in the coated web or otherwise not

emitted to the atmosphere for the compliance demonstration

procedures in Sec. 63.3370.

(4) Monthly average organic HAP content of all coating materials as-applied is less than the mass fraction of coating solids limit (Sec. 63.3320(b)(3)). Demonstrate that the monthly average as-applied organic HAP content on the basis of coating solids applied of all coating materials applied at an existing affected source is less than 0.20 kg organic HAP per kg coating solids applied, and all coating materials applied at a new affected source are less than 0.08 kg organic HAP per kg coating solids applied, as determined by Equation 5 of this section: [GRAPHIC] [TIFF OMITTED] TR04DE02.032 Where: Hs = Monthly average, as-applied, organic HAP to coating

solids ratio, kg organic HAP/kg coating solids applied.p = Number of different coating materials applied in a month.Chi = Organic HAP content of coating material, i, as-

purchased, expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material.Chij = Organic HAP content of material, j, added to as-

purchased coating material, i, expressed as a mass fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.Mvret = Mass of volatile matter retained in the coated web

after curing or drying, or otherwise not emitted to the

atmosphere, kg. The value of this term will be zero in all

cases except where you choose to take into account the

volatile matter retained in the coated web or otherwise not

emitted to the atmosphere for the compliance demonstration

procedures in Sec. 63.3370.Csi = Coating solids content of coating material, i,

expressed as a mass fraction, kg/kg.Csij = Coating solids content of material, j, added to as-

purchased coating material, i, expressed as a mass-fraction,

kg/kg.

(5) The affected source is in compliance with emission standards in Sec. 63.3320(b)(2) or (3) if:

(i) The organic HAP content of each coating material as-applied at an existing affected source is no more than 0.04 kg organic HAP per kg coating material or 0.2 kg organic HAP per kg coating solids, and the organic HAP content of each coating material as-applied at a new affected source contains no more than 0.016 kg organic HAP per kg coating material or 0.08 kg organic HAP per kg coating solids; or

(ii) The monthly average organic HAP content of all as-applied coating materials at an existing affected source are no more than 0.04 kg organic HAP per kg coating material or 0.2 kg organic HAP per kg coating solids, and the monthly average organic HAP content of all as-applied coating materials at a new affected source is no more than 0.016 kg organic HAP per kg coating material or 0.08 kg organic HAP per kg coating solids.

(d) Monthly allowable organic HAP applied. Demonstrate that the total monthly organic HAP applied as determined by Equation 6 of this section is less than the calculated equivalent allowable organic HAP as determined by Equation 13a or b in paragraph (l) of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.033 Where: Hm = Total monthly organic HAP applied, kg.p = Number of different coating materials applied in a month.Chi = Organic HAP content of coating material, i, as-

purchased, expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material. Chij = Organic HAP content of material, j, added to as-

purchased coating material, i, expressed as a mass fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.Mvret = Mass of volatile matter retained in the coated web

after curing or drying, or otherwise not emitted to the

atmosphere, kg. The value of this term will be zero in all

cases except where you choose to take into account the

volatile matter retained in the coated web or otherwise not

emitted to the atmosphere for the compliance demonstration

procedures in Sec. 63.3370.

(e) Capture and control to reduce emissions to no more than allowable limit (Sec. 63.3320(b)(1)). Operate a capture system and control device and demonstrate an overall organic HAP control efficiency of at least 95 percent at an existing affected source and at least 98 percent at a new affected source for each month, or operate a capture system and oxidizer so that an outlet organic HAP concentration of no greater than 20 ppmv by compound on a dry basis is achieved as long as the capture efficiency is 100 percent as detailed in Sec. 63.3320(b)(4). Unless one of the cases described in paragraph (e)(1), (2), or (3) of this section applies to the affected source, you must either demonstrate compliance in accordance with the procedure in paragraph (i) of this section when emissions from the affected source are controlled by a solvent recovery device, or the procedure in paragraph (k) of this section when emissions are controlled by an oxidizer or demonstrate compliance for a web coating line by operating each capture system and each control device and continuous parameter monitoring according to the procedures in paragraph (j) of this section.

(1) If the affected source has only always-controlled work stations and operates more than one capture system or more than one control device, you must demonstrate compliance in accordance with the provisions of either paragraph (n) or (p) of this section.

(2) If the affected source operates one or more never-controlled work stations or one or more intermittently-controlled work stations, you must demonstrate compliance in accordance with the provisions of paragraph (n) of this section.

(3) An alternative method of demonstrating compliance with Sec. 63.3320(b)(1) is the installation of a PTE around the web coating line that achieves 100 percent capture efficiency and ventilation of all organic HAP emissions from the total enclosure to an oxidizer with an outlet organic HAP concentration of no greater than 20 ppmv by compound on a dry basis. If this method is selected, you must demonstrate compliance by following the procedures in paragraphs (e)(3)(i) and (ii) of this section. Compliance is determined according to paragraph (e)(3)(iii) of this section.

(i) Demonstrate that a total enclosure is installed. An enclosure that meets the requirements in Sec. 63.3360(f)(1) will be considered a total enclosure.

(ii) Determine the organic HAP concentration at the outlet of your total enclosure using the procedures in paragraph (e)(3)(ii)(A) or (B) of this section.

(A) Determine the control device efficiency using Equation 2 of Sec. 63.3360 and the applicable test methods and procedures specified in Sec. 63.3360(e).

(B) Use a CEMS to determine the organic HAP emission rate according to paragraphs (i)(2)(i) through (x) of this section.

(iii) You are in compliance if the installation of a total enclosure is demonstrated and the organic HAP concentration at the outlet of the incinerator is demonstrated to be no greater than 20 ppmv by compound on a dry basis.

(f) Capture and control to achieve mass fraction of coating solids applied limit (Sec. 63.3320(b)(3)). Operate a capture system and control device and limit the organic HAP emission rate from an existing affected source to no more than 0.20 kg organic HAP emitted per kg coating solids applied, and from a new affected source to no more than 0.08 kg organic HAP emitted per kg coating solids applied as determined on a monthly average as-applied basis. If the affected source operates more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controlled work stations, then you must demonstrate compliance in accordance with the provisions of paragraph (n) of this section. Otherwise, you must demonstrate compliance following the procedure in paragraph (i) of this section when emissions from the affected source are controlled by a solvent recovery device or the procedure in paragraph (k) of this section when emissions are controlled by an oxidizer.

(g) Capture and control to achieve mass fraction limit (Sec. 63.3320(b)(2)). Operate a capture system and control device and limit the organic HAP emission rate to no more than 0.04 kg organic HAP emitted per kg coating material applied at an existing affected source, and no more than 0.016 kg organic HAP emitted per kg coating material applied at a new affected source as determined on a monthly average as-applied basis. If the affected source operates more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controlled work stations, then you must demonstrate compliance in accordance with the provisions of paragraph (n) of this section. Otherwise, you must demonstrate compliance following the procedure in paragraph (i) of this section when emissions from the affected source are controlled by a solvent recovery device or the procedure in paragraph (k) of this section when emissions are controlled by an oxidizer.

(h) Capture and control to achieve allowable emission rate. Operate a capture system and control device and limit the monthly organic HAP emissions to less than the allowable emissions as calculated in accordance with paragraph (l) of this section. If the affected source operates more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controlled work stations, then you must demonstrate compliance in accordance with the provisions of paragraph (n) of this section. Otherwise, the owner or operator must demonstrate compliance following the procedure in paragraph (i) of this section when emissions from the affected source are controlled by a solvent recovery device or the procedure in paragraph (k) of this section when emissions are controlled by an oxidizer.

(i) Solvent recovery device compliance demonstration. If you use a solvent recovery device to control emissions, you must show compliance by following the procedures in either paragraph (i)(1) or (2) of this section:

(1) Liquid-liquid material balance. Perform a monthly liquid-liquid material balance as specified in paragraphs (i)(1)(i) through (v) of this section and use the applicable equations in paragraphs (i)(1)(vi) through (ix) of this section to convert the data to units of the selected compliance option in paragraphs (e) through (h) of this section. Compliance is determined in accordance with paragraph (i)(1)(x) of this section.

(i) Determine the mass of each coating material applied on the web coating line or group of web coating lines controlled by a common solvent recovery device during the month.

(ii) If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied, organic HAP emission rate based on coating material applied, or emission of less than the calculated allowable organic HAP, determine the organic HAP content of each coating material as-applied during the month following the procedure in Sec. 63.3360(c).

(iii) Determine the volatile organic content of each coating material as-applied during the month following the procedure in Sec. 63.3360(d).

(iv) If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied or emission of less than the calculated allowable organic HAP, determine the coating solids content of each coating material applied during the month following the procedure in Sec. 63.3360(d).

(v) Determine and monitor the amount of volatile organic matter recovered for the month according to the procedures in Sec. 63.3350(d).

(vi) Recovery efficiency. Calculate the volatile organic matter collection and recovery efficiency using Equation 7 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.034 Where: Rv = Organic volatile matter collection and recovery

efficiency, percent.Mvr = Mass of volatile matter recovered in a month, kg.Mvret = Mass of volatile matter retained in the coated web

after curing or drying, or otherwise not emitted to the

atmosphere, kg. The value of this term will be zero in all

cases except where you choose to take into account the

volatile matter retained in the coated web or otherwise not

emitted to the atmosphere for the compliance demonstration

procedures in Sec. 63.3370.p = Number of different coating materials applied in a month.Cvi = Volatile organic content of coating material, i,

expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material.Cvij = Volatile organic content of material, j, added to as-

purchased coating material, i, expressed as a mass fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.

(vii) Organic HAP emitted. Calculate the organic HAP emitted during the month using Equation 8 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.035 Where: He = Total monthly organic HAP emitted, kg.Rv = Organic volatile matter collection and recovery

efficiency, percent.p = Number of different coating materials applied in a month.Chi = Organic HAP content of coating material, i, as-

purchased, expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material.Chij = Organic HAP content of material, j, added to as-

purchased coating material, i, expressed as a mass fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.Mvret = Mass of volatile matter retained in the coated web

after curing or drying, or otherwise not emitted to the

atmosphere, kg. The value of this term will be zero in all

cases except where you choose to take into account the

volatile matter retained in the coated web or otherwise not

emitted to the atmosphere for the compliance demonstration

procedures in Sec. 63.3370.

(viii) Organic HAP emission rate based on coating solids applied. Calculate the organic HAP emission rate based on coating solids applied using Equation 9 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.036 Where: L = Mass organic HAP emitted per mass of coating solids applied, kg/kg.He = Total monthly organic HAP emitted, kg.p = Number of different coating materials applied in a month.Csi = Coating solids content of coating material, i,

expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material.Csij = Coating solids content of material, j, added to as-

purchased coating material, i, expressed as a mass-fraction,

kg/kg.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.

(ix) Organic HAP emission rate based on coating materials applied. Calculate the organic HAP emission rate based on coating material applied using Equation 10 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.037 Where: S = Mass organic HAP emitted per mass of material applied, kg/kg.He = Total monthly organic HAP emitted, kg.p = Number of different coating materials applied in a month.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.q = Number of different materials added to the coating material.Mij = Mass of material, j, added to as-purchased coating

material, i, in a month, kg.

(x) You are in compliance with the emission standards in Sec. 63.3320(b) if:

(A) The volatile organic matter collection and recovery efficiency is 95 percent or greater at an existing affected source and 98 percent or greater at a new affected source; or

(B) The organic HAP emission rate based on coating solids applied is no more than 0.20 kg organic HAP per kg coating solids applied at an existing affected source and no more than 0.08 kg organic HAP per kg coating solids applied at a new affected source; or

(C) The organic HAP emission rate based on coating material applied is no more than 0.04 kg organic HAP per kg coating material applied at an existing affected source and no more than 0.016 kg organic HAP per kg coating material applied at a new affected source; or

(D) The organic HAP emitted during the month is less than the calculated allowable organic HAP as determined using paragraph (l) of this section.

(2) Continuous emission monitoring of capture system and control device performance. Demonstrate initial compliance through a performance test on capture efficiency and continuing compliance through continuous emission monitors and continuous monitoring of capture system operating parameters following the procedures in paragraphs (i)(2)(i) through (vii) of this section. Use the applicable equations specified in paragraphs (i)(2)(viii) through (x) of this section to convert the monitoring and other data into units of the selected compliance option in paragraphs (e) through (h) of this section. Compliance is determined in accordance with paragraph (i)(2)(xi) of this section.

(i) Control device efficiency. Continuously monitor the gas stream entering and exiting the control device to determine the total organic volatile matter mass flow rate (e.g., by determining the concentration of the vent gas in grams per cubic meter and the volumetric flow rate in cubic meters per second such that the total organic volatile matter mass flow rate in grams per second can be calculated) such that the control device efficiency of the control device can be calculated for each month using Equation 2 of Sec. 63.3360.

(ii) Capture efficiency monitoring. Whenever a web coating line is operated, continuously monitor the operating parameters established in accordance with Sec. 63.3350(f) to ensure capture efficiency.

(iii) Determine the percent capture efficiency in accordance with Sec. 63.3360(f).

(iv) Control efficiency. Calculate the overall organic HAP control efficiency achieved for each month using Equation 11 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.038 Where: R = Overall organic HAP control efficiency, percent.E = Organic volatile matter control efficiency of the control device,

percent.CE = Organic volatile matter capture efficiency of the capture system,

percent.

(v) If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied, organic HAP emission rate based on coating materials applied, or emission of less than the calculated allowable organic HAP, determine the mass of each coating material applied on the web coating line or group of web coating lines controlled by a common control device during the month.

(vi) If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied, organic HAP emission rate based on coating material applied, or emission of less than the calculated allowable organic HAP, determine the organic HAP content of each coating material as-applied during the month following the procedure in Sec. 63.3360(c).

(vii) If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied or emission of less than the calculated allowable organic HAP, determine the coating solids content of each coating material as-applied during the month following the procedure in Sec. 63.3360(d).

(viii) Organic HAP emitted. Calculate the organic HAP emitted during the month for each month using Equation 12 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.039 Where: He = Total monthly organic HAP emitted, kg.R = Overall organic HAP control efficiency, percent.p = Number of different coating materials applied in a month.Cahi = Monthly average, as-applied, organic HAP content of

coating material, i, expressed as a mass fraction, kg/kg.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.Mvret = Mass of volatile matter retained in the coated web

after curing or drying, or otherwise not emitted to the

atmosphere, kg. The value of this term will be zero in all

cases except where you choose to take into account the

volatile matter retained in the coated web or otherwise not

emitted to the atmosphere for the compliance demonstration

procedures in this section.

(ix) Organic HAP emission rate based on coating solids applied. Calculate the organic HAP emission rate based on coating solids applied using Equation 9 of this section.

(x) Organic HAP emission rate based on coating materials applied. Calculate the organic HAP emission rate based on coating material applied using Equation 10 of this section.

(xi) Compare actual performance to the performance required by compliance option. The affected source is in compliance with the emission standards in Sec. 63.3320(b) for each month if the capture system is operated such that the average capture system operating parameter is greater than or less than (as appropriate) the operating parameter value established in accordance with Sec. 63.3350(f); and

(A) The organic volatile matter collection and recovery efficiency is 95 percent or greater at an existing affected source and 98 percent or greater at a new affected source; or

(B) The organic HAP emission rate based on coating solids applied is no more than 0.20 kg organic HAP per kg coating solids applied at an existing affected source and no more than 0.08 kg organic HAP per kg coating solids applied at a new affected source; or

(C) The organic HAP emission rate based on coating material applied is no more than 0.04 kg organic HAP per kg coating material applied at an existing affected source and no more than 0.016 kg organic HAP per kg coating material applied at a new affected source; or

(D) The organic HAP emitted during the month is less than the calculated allowable organic HAP as determined using paragraph (l) of this section.

(j) Capture and control system compliance demonstration procedures using a CPMS. If you use an add-on control device, you must demonstrate initial compliance for each capture system and each control device through performance tests and demonstrate continuing compliance through continuous monitoring of capture system and control device operating parameters as specified in paragraphs (j)(1) through (3) of this section. Compliance is determined in accordance with paragraph (j)(4) of this section.

(1) Determine the control device destruction or removal efficiency using the applicable test methods and procedures in Sec. 63.3360(e).

(2) Determine the emission capture efficiency in accordance with Sec. 63.3360(f).

(3) Whenever a web coating line is operated, continuously monitor the operating parameters established according to Sec. 63.3350(e) and (f).

(4) You are in compliance with the emission standards in Sec. 63.3320(b) if the control device is operated such that the average operating parameter value is greater than or less than (as appropriate) the operating parameter value established in accordance with Sec. 63.3360(e) for each 3-hour period, and the capture system operating parameter is operated at an average value greater than or less than (as appropriate) the operating parameter value established in accordance with Sec. 63.3350(f); and

(i) The overall organic HAP control efficiency is 95 percent or greater at an existing affected source and 98 percent or greater at a new affected source; or

(ii) The organic HAP emission rate based on coating solids applied is no more than 0.20 kg organic HAP per kg coating solids applied at an existing affected source and no more than 0.08 kg organic HAP per kg coating solids applied at a new affected source; or

(iii) The organic HAP emission rate based on coating material applied is no more than 0.04 kg organic HAP per kg coating material applied at an existing affected source and no more than 0.016 kg organic HAP per kg coating material applied at a new affected source; or

(iv) The organic HAP emitted during the month is less than the calculated allowable organic HAP as determined using paragraph (l) of this section.

(k) Oxidizer compliance demonstration procedures. If you use an oxidizer to control emissions, you must show compliance by following the procedures in paragraph (k)(1) of this section. Use the applicable equations specified in paragraph (k)(2) of this section to convert the monitoring and other data into units of the selected compliance option in paragraph (e) through (h) of this section. Compliance is determined in accordance with paragraph (k)(3) of this section.

(1) Demonstrate initial compliance through performance tests of capture efficiency and control device efficiency and continuing compliance through continuous monitoring of capture system and control device operating parameters as specified in paragraphs (k)(1)(i) through (vi) of this section:

(i) Determine the oxidizer destruction efficiency using the procedure in Sec. 63.3360(e).

(ii) Determine the capture system capture efficiency in accordance with Sec. 63.3360(f).

(iii) Capture and control efficiency monitoring. Whenever a web coating line is operated, continuously monitor the operating parameters established in accordance with Sec. 63.3350(e) and (f) to ensure capture and control efficiency.

(iv) If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied, organic HAP emission rate based on coating materials applied, or emission of less than the calculated allowable organic HAP, determine the mass of each coating material applied on the web coating line or group of web coating lines controlled by a common oxidizer during the month.

(v) If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied, organic HAP emission rate based on coating material applied, or emission of less than the calculated allowable organic HAP, determine the organic HAP content of each coating material as-applied during the month following the procedure in Sec. 63.3360(c).

(vi) If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied or emission of less than the calculated allowable organic HAP, determine the coating solids content of each coating material applied during the month following the procedure in Sec. 63.3360(d).

(2) Convert the information obtained under paragraph (p)(1) of this section into the units of the selected compliance option using the calculation procedures specified in paragraphs (k)(2)(i) through (iv) of this section.

(i) Control efficiency. Calculate the overall organic HAP control efficiency achieved using Equation 11 of this section.

(ii) Organic HAP emitted. Calculate the organic HAP emitted during the month using Equation 12 of this section.

(iii) Organic HAP emission rate based on coating solids applied. Calculate the organic HAP emission rate based on coating solids applied for each month using Equation 9 of this section.

(iv) Organic HAP based on coating materials applied. Calculate the organic HAP emission rate based on coating material applied using Equation 10 of this section.

(3) You are in compliance with the emission standards in Sec. 63.3320(b) if the oxidizer is operated such that the average operating parameter value is greater than the operating parameter value established in accordance with Sec. 63.3360(e) for each 3-hour period, and the capture system operating parameter is operated at an average value greater than or less than (as appropriate) the operating parameter value established in accordance with Sec. 63.3350(f); and

(i) The overall organic HAP control efficiency is 95 percent or greater at an existing affected source and 98 percent or greater at a new affected source; or

(ii) The organic HAP emission rate based on coating solids applied is no more than 0.20 kg organic HAP per kg coating solids applied at an existing affected source and no more than 0.08 kg organic HAP per kg coating solids applied at a new affected source; or

(iii) The organic HAP emission rate based on coating material applied is no more than 0.04 kg organic HAP per kg coating material applied at an existing affected source and no more than 0.016 kg organic HAP per kg coating material applied at a new affected source; or

(iv) The organic HAP emitted during the month is less than the calculated allowable organic HAP as determined using paragraph (l) of this section.

(l) Monthly allowable organic HAP emissions. This paragraph provides the procedures and calculations for determining monthly allowable organic HAP emissions for use in demonstrating compliance in accordance with paragraph (d), (h), (i)(1)(x)(D), (i)(2)(xi)(D), or (k)(3)(iv) of this section. You will need to determine the amount of coating material applied at greater than or equal to 20 mass percent coating solids and the amount of coating material applied at less than 20 mass percent coating solids. The allowable organic HAP limit is then calculated based on coating material applied at greater than or equal to 20 mass percent coating solids complying with 0.2 kg organic HAP per kg coating solids at an existing affected source or 0.08 kg organic HAP per kg coating solids at a new affected source, and coating material applied at less than 20 mass percent coating solids complying with 4 mass percent organic HAP at an existing affected source and 1.6 mass-percent organic HAP at a new affected source as follows:

(1) Determine the as-purchased mass of each coating material applied each month.

(2) Determine the as-purchased coating solids content of each coating material applied each month in accordance with Sec. 63.3360(d)(1).

(3) Determine the as-purchased mass fraction of each coating material which was applied at 20 mass percent or greater coating solids content on an as-applied basis.

(4) Determine the total mass of each solvent, diluent, thinner, or reducer added to coating materials which were applied at less than 20 mass percent coating solids content on an as-applied basis each month.

(5) Calculate the monthly allowable organic HAP emissions using Equation 13a of this section for an existing affected source:[GRAPHIC] [TIFF OMITTED] TR04DE02.040 Where: Ha = Monthly allowable organic HAP emissions, kg.p = Number of different coating materials applied in a month.Mi = mass of as-purchased coating material, i, applied in a

month, kg. Gi = Mass fraction of each coating material, i, which was

applied at 20 mass percent or greater coating solids content,

on an as-applied basis, kg/kg.Csi = Coating solids content of coating material, i,

expressed as a mass fraction, kg/kg.q = Number of different materials added to the coating material.MLj = Mass of non-coating-solids-containing coating material,

j, added to coating-solids-containing coating materials which

were applied at less than 20 mass percent coating solids

content, on an as-applied basis, in a month, kg. or Equation 13b of this section for a new affected source:[GRAPHIC] [TIFF OMITTED] TR04DE02.041 Where: Ha = Monthly allowable organic HAP emissions, kg.p = Number of different coating materials applied in a month.Mi = Mass of as-purchased coating material, i, applied in a

month, kg.Gi = Mass fraction of each coating material, i, which was

applied at 20 mass percent or greater coating solids content,

on an as-applied basis, kg/kg.Csi = Coating solids content of coating material, i,

expressed as a mass fraction, kg/kg.q = Number of different materials added to the coating material.MLj = Mass of non-coating-solids-containing coating material,

j, added to coating-solids-containing coating materials which

were applied at less than 20 mass percent coating solids

content, on an as-applied basis, in a month, kg.

(m) [Reserved]

(n) Combinations of capture and control. If you operate more than one capture system, more than one control device, one or more never-controlled work stations, or one or more intermittently-controlled work stations, you must calculate organic HAP emissions according to the procedures in paragraphs (n)(1) through (4) of this section, and use the calculation procedures specified in paragraph (n)(5) of this section to convert the monitoring and other data into units of the selected control option in paragraphs (e) through (h) of this section. Use the procedures specified in paragraph (n)(6) of this section to demonstrate compliance.

(1) Solvent recovery system using liquid-liquid material balance compliance demonstration. If you choose to comply by means of a liquid-liquid material balance for each solvent recovery system used to control one or more web coating lines, you must determine the organic HAP emissions for those web coating lines controlled by that solvent recovery system either:

(i) In accordance with paragraphs (i)(1)(i) through (iii) and (v) through (vii) of this section, if the web coating lines controlled by that solvent recovery system have only always-controlled work stations; or

(ii) In accordance with paragraphs (i)(1)(ii), (iii), (v), and (vi) and (o) of this section, if the web coating lines controlled by that solvent recovery system have one or more never-controlled or intermittently-controlled work stations.

(2) Solvent recovery system using performance test compliance demonstration and CEMS. To demonstrate compliance through an initial test of capture efficiency, continuous monitoring of a capture system operating parameter, and a CEMS on each solvent recovery system used to control one or more web coating lines, you must:

(i) For each capture system delivering emissions to that solvent recovery system, monitor the operating parameter established in accordance with Sec. 63.3350(f) to ensure capture system efficiency; and

(ii) Determine the organic HAP emissions for those web coating lines served by each capture system delivering emissions to that solvent recovery system either:

(A) In accordance with paragraphs (i)(2)(i) through (iii), (v), (vi), and (viii) of this section, if the web coating lines served by that capture and control system have only always-controlled work stations; or

(B) In accordance with paragraphs (i)(2)(i) through (iii), (vi), and (o) of this section, if the web coating lines served by that capture and control system have one or more never-controlled or intermittently-controlled work stations.

(3) Oxidizer. To demonstrate compliance through performance tests of capture efficiency and control device efficiency, continuous monitoring of capture system, and CPMS for control device operating parameters for each oxidizer used to control emissions from one or more web coating lines, you must:

(i) Monitor the operating parameter in accordance with Sec. 63.3350(e) to ensure control device efficiency; and

(ii) For each capture system delivering emissions to that oxidizer, monitor the operating parameter established in accordance with Sec. 63.3350(f) to ensure capture efficiency; and

(iii) Determine the organic HAP emissions for those web coating lines served by each capture system delivering emissions to that oxidizer either:

(A) In accordance with paragraphs (k)(1)(i) through (vi) of this section, if the web coating lines served by that capture and control system have only always-controlled work stations; or

(B) In accordance with paragraphs (k)(1)(i) through (iii), (v), and (o) of this section, if the web coating lines served by that capture and control system have one or more never-controlled or intermittently-controlled work stations.

(4) Uncontrolled coating lines. If you own or operate one or more uncontrolled web coating lines, you must determine the organic HAP applied on those web coating lines using Equation 6 of this section. The organic HAP emitted from an uncontrolled web coating line is equal to the organic HAP applied on that web coating line.

(5) Convert the information obtained under paragraphs (n)(1) through (4) of this section into the units of the selected compliance option using the calculation procedures specified in paragraphs (n)(5)(i) through (iv) of this section.

(i) Organic HAP emitted. Calculate the organic HAP emissions for the affected source for the month by summing all organic HAP emissions calculated according to paragraphs (n)(1), (2)(ii), (3)(iii), and (4) of this section.

(ii) Coating solids applied. If demonstrating compliance on the basis of organic HAP emission rate based on coating solids applied or emission of less than the calculated allowable organic HAP, the owner or operator must determine the coating solids content of each coating material applied during the month following the procedure in Sec. 63.3360(d).

(iii) Organic HAP emission rate based on coating solids applied. Calculate the organic HAP emission rate based on coating solids applied for each month using Equation 9 of this section.

(iv) Organic HAP based on materials applied. Calculate the organic HAP emission rate based on material applied using Equation 10 of this section.

(6) Compliance. The affected source is in compliance with the emission standards in Sec. 63.3320(b) for the month if all operating parameters required to be monitored under paragraphs (n)(1) through (3) of this section were maintained at the values established under Sec. Sec. 63.3350 and 63.3360; and

(i) The total mass of organic HAP emitted by the affected source based on coating solids applied is no more than 0.20 kg organic HAP per kg coating solids applied at an existing affected source and no more than 0.08 kg organic HAP per kg coating solids applied at a new affected source; or

(ii) The total mass of organic HAP emitted by the affected source based on material applied is no more than 0.04 kg organic HAP per kg material applied at an existing affected source and no more than 0.016 kg organic HAP per kg material applied at a new affected source; or

(iii) The total mass of organic HAP emitted by the affected source during the month is less than the calculated allowable organic HAP as determined using paragraph (l) of this section; or

(iv) The total mass of organic HAP emitted by the affected source was not more than 5 percent of the total mass of organic HAP applied for the month at an existing affected source and no more than 2 percent of the total mass of organic HAP applied for the month at a new affected source. The total mass of organic HAP applied by the affected source in the month must be determined using Equation 6 of this section.

(o) Intermittently-controlled and never-controlled work stations. If you have been expressly referenced to this paragraph by paragraphs (n)(1)(ii), (n)(2)(ii)(B), or (n)(3)(iii)(B) of this section for calculation procedures to determine organic HAP emissions for your intermittently-controlled and never-controlled work stations, you must:

(1) Determine the sum of the mass of all coating materials as-applied on intermittently-controlled work stations operating in bypass mode and the mass of all coating materials as-applied on never-controlled work stations during the month.

(2) Determine the sum of the mass of all coating materials as-applied on intermittently-controlled work stations operating in a controlled mode and the mass of all coating materials applied on always-controlled work stations during the month.

(3) Liquid-liquid material balance compliance demonstration. For each web coating line or group of web coating lines for which you use the provisions of paragraph (n)(1)(ii) of this section, you must calculate the organic HAP emitted during the month using Equation 14 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.042 Where: He = Total monthly organic HAP emitted, kg.p = Number of different coating materials applied in a month.Mci = Sum of the mass of coating material, i, as-applied on

intermittently-controlled work stations operating in

controlled mode and the mass of coating material, i, as-

applied on always-controlled work stations, in a month, kg.Cahi = Monthly average, as-applied, organic HAP content of

coating material, i, expressed as a mass fraction, kg/kg.Rv = Organic volatile matter collection and recovery

efficiency, percent.MBi = Sum of the mass of coating material, i, as-applied on

intermittently-controlled work stations operating in bypass

mode and the mass of coating material, i, as-applied on never-

controlled work stations, in a month, kg.Cahi = Monthly average, as-applied, organic HAP content of

coating material, i, expressed as a mass fraction, kg/kg.Mvret = Mass of volatile matter retained in the coated web

after curing or drying, or otherwise not emitted to the

atmosphere, kg. The value of this term will be zero in all

cases except where you choose to take into account the

volatile matter retained in the coated web or otherwise not

emitted to the atmosphere for the compliance demonstration

procedures in this section.

(4) Performance test to determine capture efficiency and control device efficiency. For each web coating line or group of web coating lines for which you use the provisions of paragraph (n)(2)(ii)(B) or (n)(3)(iii)(B) of this section, you must calculate the organic HAP emitted during the month using Equation 15 of this section:[GRAPHIC] [TIFF OMITTED] TR04DE02.043 Where: He = Total monthly organic HAP emitted, kg. p = Number of different coating materials applied in a month.Mci = Sum of the mass of coating material, i, as-applied on

intermittently-controlled work stations operating in

controlled mode and the mass of coating material, i, as-

applied on always-controlled work stations, in a month, kg.Cahi = Monthly average, as-applied, organic HAP content of

coating material, i, expressed as a mass fraction, kg/kg.R = Overall organic HAP control efficiency, percent.MBi = Sum of the mass of coating material, i, as-applied on

intermittently-controlled work stations operating in bypass

mode and the mass of coating material, i, as-applied on never-

controlled work stations, in a month, kg.Cahi = Monthly average, as-applied, organic HAP content of

coating material, i, expressed as a mass fraction, kg/kg.Mvret = Mass of volatile matter retained in the coated web

after curing or drying, or otherwise not emitted to the

atmosphere, kg. The value of this term will be zero in all

cases except where you choose to take into account the

volatile matter retained in the coated web or otherwise not

emitted to the atmosphere for the compliance demonstration

procedures in this section.

(p) Always-controlled work stations with more than one capture and control system. If you operate more than one capture system or more than one control device and only have always-controlled work stations, then you are in compliance with the emission standards in Sec. 63.3320(b)(1) for the month if for each web coating line or group of web coating lines controlled by a common control device:

(1) The volatile matter collection and recovery efficiency as determined by paragraphs (i)(1)(i), (iii), (v), and (vi) of this section is at least 95 percent at an existing affected source and at least 98 percent at a new affected source; or

(2) The overall organic HAP control efficiency as determined by paragraphs (i)(2)(i) through (iv) of this section for each web coating line or group of web coating lines served by that control device and a common capture system is at least 95 percent at an existing affected source and at least 98 percent at a new affected source; or

(3) The overall organic HAP control efficiency as determined by paragraphs (k)(1)(i) through (iii) and (k)(2)(i) of this section for each web coating line or group of web coating lines served by that control device and a common capture system is at least 95 percent at an existing affected source and at least 98 percent at a new affected source.

Notifications, Reports, and Records