Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 63  /  Sec. 63.4341 How do I demonstrate initial compliance?

(a) You may use the emission rate with add-on controls option for any individual web coating/printing operation, for any group of web coating/printing operations in the affected source, or for all of the web coating/printing operations in the affected source. You may include both controlled and uncontrolled web coating/printing operations in a group for which you use this option. You must use either the compliant material option, the emission rate without add-on controls option, the organic HAP overall control efficiency option, or the oxidizer outlet organic HAP concentration option for any web coating/printing operation in the affected source for which you do not use the emission rate with add-on controls option. To demonstrate initial compliance, any web coating/printing operation for which you use the emission rate with add-on controls option must meet the applicable emission limitations in Table 1 to this subpart, and in Sec. Sec. 63.4292 and 63.4293. You must meet all the requirements of paragraphs (a), (c), (d), and (e) of this section. When calculating the organic HAP emission rate according to this section, do not include any coating, printing, thinning, or cleaning materials applied on web coating/printing operations for which you use the compliant material option, the emission rate without add-on controls option, the organic HAP overall control efficiency option, or the oxidizer outlet organic HAP concentration option. You do not need to redetermine the mass of organic HAP in coating, printing, thinning, or cleaning materials that have been reclaimed onsite and reused in the web coating/printing operation(s) for which you use the emission rate with add-on control option.

(b) You may use the emission rate with add-on controls option for any individual dyeing/finishing operation, for any group of dyeing/finishing operations in the affected source, or for all of the dyeing/finishing operations in the affected source. You may include both controlled and uncontrolled dyeing/finishing operations in a group for which you use this option. You must use either the compliant material option or the emission rate without add-on controls option for any dyeing/finishing operation in the affected source for which you do not use the emission rate with add-on controls option. You may not use the emission rate with add-on controls option for any dyeing/finishing operation in a dyeing/finishing affected source for which you use the equivalent emission rate option. To demonstrate initial compliance, any dyeing/finishing operation for which you use the emission rate with add-on controls option must meet the applicable emission limitations in Table 1 to this subpart, and in Sec. Sec. 63.4292 and 63.4293. You must meet all the requirements of paragraphs (b), (c), (d), and (f) this section. When calculating the organic HAP emission rate according to this section, do not include any dyeing or finishing materials applied on dyeing/finishing operations for which you use the compliant material option or the emission rate without add-on controls option. You do not need to redetermine the mass of organic HAP in dyeing or finishing materials that have been reclaimed onsite and reused in the dyeing/finishing operation(s) for which you use the emission rate with add-on controls option.

(c) Compliance with operating limits. Except as provided in Sec. 63.4340(a)(4), and except for solvent recovery systems for which you conduct liquid-liquid material balances according to Sec. 63.4341(e)(5) or (f)(5), you must establish and demonstrate continuous compliance during the initial compliance period with the operating limits required by Sec. 63.4292, using the procedures specified in Sec. Sec. 63.4363 and 63.4364.

(d) Compliance with work practice requirements. You must develop, implement, and document your implementation of the work practice plan required by Sec. 63.4293 during the initial compliance period as specified in Sec. 63.4312.

(e) Compliance with web coating/printing emission limits. You must follow the procedures in paragraphs (e)(1) through (8) of this section to demonstrate compliance with the applicable web coating/printing emission limit in Table 1 to this subpart.

(1) Determine the mass fraction of organic HAP, the mass fraction of solids, and mass of materials. Follow the procedures specified in Sec. 63.4331(a)(1), (2), and (3) to determine the mass fraction of organic HAP for each coating, printing, thinning, and cleaning material applied during the compliance period; the mass fraction of solids for each coating and printing material applied during the compliance period; and mass of each coating, printing, thinning, and cleaning material applied during the compliance period.

(2) Calculate the mass of organic HAP emissions before add-on controls. Using Equation 1 of Sec. 63.4331, calculate the mass of organic HAP emissions before add-on controls from all coating, printing, thinning, and cleaning materials applied during the compliance period minus the organic HAP in certain waste materials in the web coating/printing operation or group of web coating/printing operations for which you use the emission rate with add-on controls.

(3) Calculate the organic HAP emissions reductions for each controlled web coating/printing operation. Determine the mass of organic HAP emissions reduced for each controlled web coating/printing operation during the compliance period. The emissions reductions determination quantifies the total organic HAP emissions that pass through the emission capture system and are destroyed or removed by the add-on control device. Use the procedures in paragraph (e)(4) of this section to calculate the mass of organic HAP emissions reductions for each controlled web coating/printing operation using an emission capture system and add-on control device other than a solvent recovery system for which you conduct liquid-liquid material balances. For each controlled web coating/printing operation using a solvent recovery system for which you conduct a liquid-liquid material balance, use the procedures in paragraph (e)(5) of this section to calculate the organic HAP emissions reductions.

(4) Calculate the organic HAP emission reduction for each controlled web coating/printing operation not using liquid-liquid material balance. For each controlled web coating/printing operation using an emission capture system and add-on control device other than a solvent recovery system for which you conduct liquid-liquid material balances, calculate the organic HAP emissions reductions using Equation 1 of this section. The equation applies the emission capture system efficiency and add-on control device efficiency to the mass of organic HAP contained in the coating, printing, thinning, and cleaning materials applied in the web coating/printing operation served by the emission capture system and add-on control device during the compliance period. For any period of time a deviation specified in Sec. 63.4342(c) or (d) occurs in the controlled web coating/printing operation, including a deviation during startup, shutdown, or malfunction, then you must assume zero efficiency for the emission capture system and add-on control device. Equation 1 of this section treats the coating, printing, thinning, and cleaning materials applied during such a deviation as if they were used on an uncontrolled web coating/printing operation for the time period of the deviation.[GRAPHIC] [TIFF OMITTED] TR29MY03.011 Where: HC = Mass of organic HAP emission reduction for the

controlled web coating/printing operation during the

compliance period, kg.AI = Total mass of organic HAP in the coating and printing

materials applied in the controlled web coating/printing

operation during the compliance period, kg, as calculated in

Equation 1A of this section.BI = Total mass of organic HAP in the thinning and cleaning

materials applied in the controlled web coating/printing

operation during the compliance period, kg, as calculated in

Equation 1B of this section.HUNC = Total mass of organic HAP in the coating, printing,

thinning, and cleaning materials applied during all deviations

specified in Sec. 63.4342(c) and (d) that occurred during the

compliance period in the controlled web coating/printing

operation, kg, as calculated in Equation 1C of this section.CE = Capture efficiency of the emission capture system vented to the

add-on control device, percent. Use the test methods and

procedures specified in Sec. Sec. 63.4360 and 63.4361 to

measure and record capture efficiency.DRE = Organic HAP destruction or removal efficiency of the add-on

control device, percent. Use the test methods and procedures

in Sec. Sec. 63.4360 and 63.4362 to measure and record the

organic HAP destruction or removal efficiency.

(i) Calculate the total mass of organic HAP in the coating and printing materials applied in the controlled web coating/printing operation(s) during the compliance period, kg, using Equation 1A of this section:[GRAPHIC] [TIFF OMITTED] TR29MY03.012 Where: AI = Total mass of organic HAP in the coating and printing

materials applied in the controlled web coating/printing

operation(s) during the compliance period, kg.Mc,i = Mass of coating or printing material, i, applied

during the compliance period, kg.Wc,i = Mass fraction of organic HAP in coating or printing

material, i, kg per kg.m = Number of different coating and printing materials applied during

compliance period.

(ii) Calculate the total mass of organic HAP in the thinning and cleaning materials applied in the controlled web coating/printing operation(s) during the compliance period, kg, using Equation 1B of this section:[GRAPHIC] [TIFF OMITTED] TR29MY03.013 Where: BI = Total mass of organic HAP in the thinning and cleaning

materials applied in the controlled web coating/printing

operation(s) during the compliance period, kg.Mt,j = Total mass of thinning or cleaning material, j,

applied during the compliance period, kg.Wt,j = Mass fraction of organic HAP in thinning or cleaning

material, j, kg per kg.n = Number of different thinning and cleaning materials applied during

the compliance period.

(iii) Calculate the mass of organic HAP in the coating, printing, thinning, and cleaning materials applied in the controlled web coating/printing operation during deviations specified in Sec. 63.4342(c) and (d), using Equation 1C of this section.[GRAPHIC] [TIFF OMITTED] TR29MY03.014 Where: HUNC = Total mass of organic HAP in the coating, printing,

thinning, and cleaning materials applied during all deviations

specified in Sec. 63.4342 (c) and (d) that occurred during

the compliance period in the controlled web coating/printing

operation, kg.Mh = Total mass of coating, printing, thinning, or cleaning

material, h, applied in the controlled web coating/printing

operation during deviations, kg.Wh = Mass fraction of organic HAP in coating, printing,

thinning, or cleaning material, h, kg organic HAP per kg

material.q = Number of different coating, printing, thinning, and cleaning

materials applied and used.

(5) Calculate the organic HAP emissions reductions for controlled web coating/printing operation using liquid-liquid material balances. For each controlled web coating/printing operation using a solvent recovery system for which you conduct liquid-liquid material balances, calculate the organic HAP emissions reductions by applying the volatile organic matter collection and recovery efficiency to the mass of organic HAP contained in the coating, printing, thinning, and cleaning materials applied in the web coating/printing operation controlled by the solvent recovery system during the compliance period. Perform a liquid-liquid material balance for the compliance period as specified in paragraphs (e)(5)(i) through (v) of this section. Calculate the mass of organic HAP emissions reductions by the solvent recovery system as specified in paragraph (e)(5)(vi) of this section.

(i) For each solvent recovery system, install, calibrate, maintain, and operate according to the manufacturer's specifications, a device that indicates the cumulative amount of volatile organic matter recovered by the solvent recovery system for the compliance period. The device must be initially certified by the manufacturer to be accurate to within 2.0 percent of the mass of volatile organic matter recovered.

(ii) For each solvent recovery system, determine the mass of volatile organic matter recovered for the compliance period, kg, based on measurement with the device required in paragraph (e)(5)(i) of this section.

(iii) Determine the mass fraction of volatile organic matter for each coating, printing, cleaning, and thinning material applied in the web coating/printing operation controlled by the solvent recovery system during the compliance period, kg volatile organic matter per kg coating, printing, cleaning, and thinning material. You may determine the volatile organic matter mass fraction using Method 24 of 40 CFR part 60, appendix A, or an EPA approved alternative method, or you may use information provided by the manufacturer or supplier of the coating or printing material. In the event of any inconsistency between information provided by the manufacturer or supplier and the results of Method 24 of 40 CFR part 60, appendix A, or an approved alternative method, the test method results will govern.

(iv) Measure the mass of each coating, printing, thinning, and cleaning material applied in the web coating/printing operation controlled by the solvent recovery system during the compliance period, kg.

(v) For the compliance period, calculate the solvent recovery system's volatile organic matter collection and recovery efficiency using Equation 2 of this section: [GRAPHIC] [TIFF OMITTED] TR29MY03.015 Where: RV = Volatile organic matter collection and recovery

efficiency of the solvent recovery system during the

compliance period, percent.MVR = Mass of volatile organic matter recovered by the

solvent recovery system during the compliance period, kg.Mi = Mass of coating or printing material, i, applied in the

web coating/printing operation controlled by the solvent

recovery system during the compliance period, kg.WVc,i = Mass fraction of volatile organic matter for coating

or printing material, i, kg volatile organic matter per kg

coating or printing material.Mj = Mass of thinning or cleaning material, j, applied in the

web coating/printing operation controlled by the solvent

recovery system during the compliance period, kg.WVt,j = Mass fraction of volatile organic matter for thinning

or cleaning material, j, kg volatile organic matter per kg

thinning or cleaning material.m = Number of different coating and printing materials applied in the

web coating/printing operation controlled by the solvent

recovery system during the compliance period.n = Number of different thinning and cleaning materials applied in the

web coating/printing operation controlled by the solvent

recovery system during the compliance period.

(vi) Calculate the mass of organic HAP emission reductions for the web coating/printing operation controlled by the solvent recovery system during the compliance period using Equation 3 of this section and according to paragraphs (e)(5)(vi)(A) and (B) of this section:[GRAPHIC] [TIFF OMITTED] TR29MY03.016 Where: HCSR = Mass of organic HAP emission reduction for the web

coating/printing operation controlled by the solvent recovery

system during the compliance period, kg.ACSR = Total mass of organic HAP in the coating and printing

material applied in the web coating/printing operation

controlled by the solvent recovery system during the

compliance period, kg, calculated using Equation 3A of this

section.BCSR = Total mass of organic HAP in the thinning and cleaning

materials applied in the web coating/printing operation

controlled by the solvent recovery system during the

compliance period, kg, calculated using Equation 3B of this

section.RV = Volatile organic matter collection and recovery

efficiency of the solvent recovery system, percent, from

Equation 2 of this section.

(A) Calculate the total mass of organic HAP in the coating and printing materials applied in the web coating/printing operation(s) controlled by the solvent recovery system during the compliance period, kg, using Equation 3A of this section:[GRAPHIC] [TIFF OMITTED] TR29MY03.017 Where: ACSR = Total mass of organic HAP in the coating and printing

materials applied in the web coating/printing operations(s)

controlled by the solvent recovery system during the

compliance period, kg.Mc,i = Mass of coating or printing material, i, applied

during the compliance period in the web coating/printing

operation(s) controlled by the solvent recovery system, kg.Wc,i = Mass fraction of organic HAP in coating or printing

material, i, kg per kg.m = Number of different coating and printing materials applied during

compliance period.

(B) Calculate the total mass of organic HAP in the thinning and cleaning materials applied in the web coating/printing operation(s) controlled by the solvent recovery system during the compliance period, kg, using Equation 3B of this section:[GRAPHIC] [TIFF OMITTED] TR29MY03.018 Where: BCSR = Total mass of organic HAP in the thinning and cleaning

materials applied in the web coating/printing operation(s)

controlled by the solvent recovery system during the

compliance period, kg.Mt,j = Total mass of thinning or cleaning material, j,

applied during the compliance period in the web coating/

printing operation(s) controlled by the solvent recovery

system, kg.Wt,j = Mass fraction of organic HAP in thinning or cleaning

material, j, kg per kg.n = Number of different thinning and cleaning materials applied during

the compliance period.

(6) Calculate the total mass of coating and printing solids. Determine the total mass of coating and printing solids applied, kg, which is the combined mass of the solids contained in all the coating and printing material applied during the compliance period in the web coating/printing operation(s) for which you use the emission rate with add-on controls option, using Equation 2 of Sec. 63.4331.

(7) Calculate the organic HAP emission rate with add-on controls for the compliance period. Determine the organic HAP emission rate with add-on controls for the compliance period, kg organic HAP emitted per kg solids applied during the compliance period, using Equation 4 of this section.[GRAPHIC] [TIFF OMITTED] TR29MY03.019 Where: HHAP = Organic HAP emission rate with add-on controls for the

compliance period, kg organic HAP emitted per kg solids

applied.He = Total mass of organic HAP emissions before add-on

controls from all the coating, printing, thinning, and

cleaning materials applied during the compliance period, kg,

determined according to paragraph (e)(2) of this section.HC,i = Total mass of organic HAP emissions reduction for

controlled web coating/printing operation, i, not using a

liquid-liquid material balance, during the compliance period,

kg, from Equation 1 of this section.HCSR,j = Total mass of organic HAP emissions reduction for

web coating/printing operation, j, controlled by a solvent

recovery system using a liquid-liquid material balance, during

the compliance period, kg, from Equation 3 of this section.Ht = Total mass of coating and printing solids applied during

the compliance period, kg, from Equation 2 of Sec. 63.4331.q = Number of controlled web coating/printing operations not using a

liquid-liquid material balance.r = Number of web coating/printing operations controlled by a solvent

recovery system using a liquid-liquid material balance.

(8) Compliance demonstration. To demonstrate initial compliance with the emission limit, the organic HAP emission rate with add-on controls for the compliance period, calculated using Equation 4 of this section, must be less than or equal to the applicable emission limit in Table 1 to this subpart. You must keep all records as required by Sec. Sec. 63.4312 and 63.4313. As part of the Notification of Compliance Status required by Sec. 63.4310, you must identify the web coating/printing operation(s) for which you used the emission rate with add-on controls option and submit a statement that the web coating/printing operation(s) was (were) in compliance with the emission limitations during the initial compliance period because the organic HAP emission rate was less than or equal to the applicable emission limit in Table 1 to this subpart, and that you achieved the operating limits required by Sec. 63.4292 and the work practice standards required by Sec. 63.4293.

(f) Compliance with dyeing/finishing emission limits. You must follow the procedures in paragraphs (f)(1) through (8) of this section to demonstrate compliance with the applicable dyeing/finishing emission limit in Table 1 to this subpart.

(1) Determine the mass fraction of organic HAP and mass of materials. Follow the procedures specified in Sec. 63.4331(b)(1) and (2) to determine the mass fraction of organic HAP for each dyeing and finishing material applied and mass of each dyeing and finishing material applied during the compliance period.

(2) Calculate the mass of organic HAP emissions before add-on controls. Using Equation 4 of Sec. 63.4331, calculate the mass of organic HAP emissions before add-on controls from all dyeing and finishing materials applied during the compliance period minus the organic HAP in certain waste materials and wastewaters in the dyeing/finishing operation or group of dyeing/finishing operations for which you use the emission rate with add-on controls option.

(3) Calculate the organic HAP emissions reductions for each controlled dyeing/finishing operation. Determine the mass of organic HAP emissions reduced for each controlled dyeing/finishing operation during the compliance period. The emissions reductions determination quantifies the total organic HAP emissions that pass through the emission capture system and are destroyed or removed by the add-on control device. Use the procedures in paragraph (f)(4) of this section to calculate the mass of organic HAP emissions reductions for each controlled dyeing/finishing operation using an emission capture system and add-on control device other than a solvent recovery system for which you conduct liquid-liquid material balances. For each controlled dyeing/finishing operation using a solvent recovery system for which you conduct a liquid-liquid material balance, use the procedures in paragraph (f)(5) of this section to calculate the organic HAP emissions reductions.

(4) Calculate the organic HAP emission reduction for each controlled dyeing/finishing operation not using liquid-liquid material balance. For each controlled dyeing/finishing operation using an emission capture system and add-on control device other than a solvent recovery system for which you conduct liquid-liquid material balances, calculate the organic HAP emissions reductions using Equation 5 of this section. The equation applies the emission capture system efficiency and add-on control device efficiency to the mass of organic HAP contained in the dyeing and finishing materials applied in the dyeing/finishing operation served by the emission capture system and add-on control device during the compliance period. For any period of time a deviation specified in Sec. 63.4342(c) or (d) occurs in the controlled dyeing/finishing operation, including a deviation during startup, shutdown, or malfunction, then you must assume zero efficiency for the emission capture system and add-on control device. Equation 5 of this section treats the dyeing and finishing materials applied during such a deviation as if they were applied on an uncontrolled dyeing/finishing operation for the time period of the deviation.[GRAPHIC] [TIFF OMITTED] TR29MY03.020 Where: HC = Mass of organic HAP emission reduction for the

controlled dyeing/finishing operation during the compliance

period, kg.AI = Total mass of organic HAP in the dyeing and finishing

materials applied in the controlled dyeing/finishing operation

during the compliance period, kg, as calculated in Equation 5A

of this section.HUNC = Total mass of organic HAP in the dyeing and finishing

materials applied during all deviations specified in Sec.

63.4342(c) and (d) that occurred during the compliance period

in the controlled dyeing/finishing operation, kg, as

calculated in Equation 5B of this section.CE = Capture efficiency of the emission capture system vented to the

add-on control device, percent. Use the test methods and

procedures specified in Sec. Sec. 63.4360 and 63.4361 to

measure and record capture efficiency.DRE = Organic HAP destruction or removal efficiency of the add-on

control device, percent. Use the test methods and procedures

in Sec. Sec. 63.4360 and 63.4362 to measure and record the

organic HAP destruction or removal efficiency.

(i) Calculate the total mass of organic HAP in the dyeing and finishing materials applied in the controlled dyeing/finishing operation(s) during the compliance period, kg, using Equation 5A of this section: [GRAPHIC] [TIFF OMITTED] TR29MY03.021 Where: AI = Total mass of organic HAP in the dyeing and finishing

materials applied in the controlled dyeing/finishing

operations(s) during the compliance period, kg.Mc,i = Mass of dyeing or finishing material, i, applied

during the compliance period, kg.Wc,i = Mass fraction of organic HAP in dyeing or finishing

material, i, kg per kg.m = Number of different dyeing and finishing materials applied during

compliance period.

(ii) Calculate the mass of organic HAP in the dyeing and finishing materials applied in the controlled dyeing/finishing operation during deviations specified in Sec. 63.4342(c) and (d), using Equation 5B of this section.[GRAPHIC] [TIFF OMITTED] TR29MY03.022 Where: HUNC = Total mass of organic HAP in the dyeing and finishing

materials applied during all deviations specified in Sec.

63.4342(c) and (d) that occurred during the compliance period

in the controlled dyeing/finishing operation, kg.Mh = Total mass of dyeing and finishing material, h, applied

in the controlled dyeing/finishing operation during

deviations, kg.Wh = Mass fraction of organic HAP in dyeing or finishing

material, h, kg organic HAP per kg material.q = Number of different dyeing and finishing materials applied.

(5) Calculate the organic HAP emissions reductions for controlled dyeing/finishing operation using liquid-liquid material balances. For each controlled dyeing/finishing operation using a solvent recovery system for which you conduct liquid-liquid material balances, calculate the organic HAP emissions reductions by applying the volatile organic matter collection and recovery efficiency to the mass of organic HAP contained in the dyeing and finishing materials applied in the dyeing/finishing operation controlled by the solvent recovery system during the compliance period. Perform a liquid-liquid material balance for the compliance period as specified in paragraphs (f)(5)(i) through (v) of this section. Calculate the mass of organic HAP emissions reductions by the solvent recovery system as specified in paragraph (f)(5)(vi) of this section.

(i) For each solvent recovery system, install, calibrate, maintain, and operate according to the manufacturer's specifications, a device that indicates the cumulative amount of volatile organic matter recovered by the solvent recovery system for the compliance period. The device must be initially certified by the manufacturer to be accurate to within 2.0 percent of the mass of volatile organic matter recovered.

(ii) For each solvent recovery system, determine the mass of volatile organic matter recovered for the compliance period, kg, based on measurement with the device required in paragraph (f)(5)(i) of this section.

(iii) Determine the mass fraction of volatile organic matter for each dyeing and finishing material applied in the dyeing/finishing operation controlled by the solvent recovery system during the compliance period, kg volatile organic matter per kg dyeing and finishing material. You may determine the volatile organic matter mass fraction using information provided by the manufacturer or supplier of the dyeing or finishing material.

(iv) Measure the mass of each dyeing and finishing material applied in the dyeing/finishing operation controlled by the solvent recovery system during the compliance period, kg.

(v) For the compliance period, calculate the solvent recovery system's volatile organic matter collection and recovery efficiency using Equation 6 of this section:[GRAPHIC] [TIFF OMITTED] TR29MY03.023 Where: RV = Volatile organic matter collection and recovery

efficiency of the solvent recovery system during the

compliance period, percent.MVR = Mass of volatile organic matter recovered by the

solvent recovery system during the compliance period, kg.Mi = Mass of dyeing or finishing material, i, applied in the

dyeing/finishing operation controlled by the solvent recovery

system during the compliance period, kg. WVc,i = Mass fraction of volatile organic matter for dyeing

or finishing material, i, kg volatile organic matter per kg

dyeing or finishing material.m = Number of different dyeing and finishing materials applied in the

dyeing/finishing operation controlled by the solvent recovery

system during the compliance period.

(vi) Calculate the mass of organic HAP emission reductions for the dyeing/finishing operation controlled by the solvent recovery system during the compliance period using Equation 7 of this section and according to paragraph (f)(5)(vi)(A) of this section:[GRAPHIC] [TIFF OMITTED] TR29MY03.024 Where: HCSR = Mass of organic HAP emission reduction for the dyeing/

finishing operation controlled by the solvent recovery system

during the compliance period, kg.ACSR = Total mass of organic HAP in the dyeing and finishing

material applied in the dyeing/finishing operation controlled

by the solvent recovery system during the compliance period,

kg, calculated using Equation 7A of this section.RV = Volatile organic matter collection and recovery

efficiency of the solvent recovery system, percent, from

Equation 6 of this section.

(A) Calculate the total mass of organic HAP in the dyeing and finishing materials applied in the dyeing/finishing operation(s) controlled by the solvent recovery system during the compliance period, kg, using Equation 7A of this section:[GRAPHIC] [TIFF OMITTED] TR29MY03.025 Where: ACSR = Total mass of organic HAP in the dyeing and finishing

materials applied in the dyeing/finishing operations(s)

controlled by the solvent recovery system during the

compliance period, kg.Mc,i = Mass of dyeing or finishing material, i, applied

during the compliance period in the dyeing/finishing

operation(s) controlled by the solvent recovery system, kg.Wc,i = Mass fraction of organic HAP in dyeing or finishing

material, i, kg per kg.m = Number of different dyeing and finishing materials applied during

compliance period.

(6) Calculate the total mass of dyeing and finishing materials. Determine the total mass of dyeing and finishing materials applied, kg, which is the combined mass of all the dyeing and finishing materials applied during the compliance period in the dyeing/finishing operation(s) for which you use the emission rate with add-on controls option, using Equation 5 of Sec. 63.4331.

(7) Calculate the organic HAP emission rate with add-on controls for the compliance period. Determine the organic HAP emission rate with add-on controls for the compliance period, kg organic HAP emitted per kg dyeing and finishing materials applied during the compliance period, using Equation 8 of this section.[GRAPHIC] [TIFF OMITTED] TR29MY03.026 Where: HHAP = Organic HAP emission rate with add-on controls for the

compliance period, kg organic HAP emitted per kg dyeing and

finishing materials applied.He = Total mass of organic HAP emissions before add-on

controls from all the dyeing and finishing materials applied

during the compliance period, kg, determined according to

paragraph (f)(2) of this section.HC,i = Total mass of organic HAP emissions reductions for

controlled dyeing/finishing operation, i, not using a liquid-

liquid material balance, during the compliance period, kg,

from Equation 5 of this section.HCSR,j = Total mass of organic HAP emissions reductions for

dyeing/finishing operation,

j, controlled by a solvent recovery system using a liquid-

liquid material balance, during the compliance period, kg,

from Equation 7 of this section.Mt = Total mass of dyeing and finishing materials applied

during the compliance period, kg, from Equation 5 of Sec.

63.4331.q = Number of controlled dyeing/finishing operations not using a liquid-

liquid material balance.r = Number of dyeing/finishing operations controlled by a solvent

recovery system using a liquid-liquid material balance.

(8) Compliance demonstration. To demonstrate initial compliance with the emission limit, the organic HAP emission rate with add-on controls for the compliance period, calculated using Equation 8 of this section, must be less than or equal to the applicable emission limit in Table 1 to this subpart. You must keep all records as required by Sec. Sec. 63.4312 and 63.4313. As part of the Notification of Compliance Status required by Sec. 63.4310, you must identify the dyeing/finishing operation(s) for which you used the emission rate with add-on controls option and submit a statement that the dyeing/finishing operation(s) was (were) in compliance with the emission limitations during the initial compliance period because the organic HAP emission rate was less than or equal to the applicable emission limit in Table 1 to this subpart, and that you achieved the operating limits required by Sec. 63.4292 and the work practice standards required by Sec. 63.4293.