Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 63  /  Sec. 63.806 Recordkeeping requirements.

(a) The owner or operator of an affected source subject to this subpart shall fulfill all recordkeeping requirements of Sec. 63.10 of subpart A, according to the applicability criteria in Sec. 63.800(d) of this subpart.

(b) The owner or operator of an affected source subject to the emission limits in Sec. 63.802 of this subpart shall maintain records of the following:

(1) A certified product data sheet for each finishing material, thinner, contact adhesive, and strippable spray booth coating subject to the emission limits in Sec. 63.802; and

(2) The VHAP content, in kg VHAP/kg solids (lb VHAP/lb solids), as applied, of each finishing material and contact adhesive subject to the emission limits in Sec. 63.802; and

(3) The VOC content, in kg VOC/kg solids (lb VOC/lb solids), as applied, of each strippable booth coating subject to the emission limits in Sec. 63.802 (a)(3) or (b)(3).

(4) The formaldehyde content, in lb/gal, as applied, of each finishing material and contact adhesive subject to the emission limits in Sec. 63.802(a)(4) or (b)(4) and chooses to comply with the 400 lb/yr limits on formaldehyde in Sec. 63.802(a)(4) (i) or (b)(4)(i).

(c) The owner or operator of an affected source following the compliance method in Sec. 63.804 (a)(1) or (d)(1) shall maintain copies of the averaging calculation for each month following the compliance date, as well as the data on the quantity of coatings and thinners used that is necessary to support the calculation of E in Equation 1.

(d) The owner or operator of an affected source following the compliance procedures of Sec. 63.804 (f)(3)(ii) and (g)(3)(ii) shall maintain the records required by Sec. 63.806(b) as well as records of the following:

(1) Solvent and coating additions to the continuous coater reservoir;

(2) Viscosity measurements; and

(3) Data demonstrating that viscosity is an appropriate parameter for demonstrating compliance.

(e) The owner or operator of an affected source subject to the work practice standards in Sec. 63.803 of this subpart shall maintain onsite the work practice implementation plan and all records associated with fulfilling the requirements of that plan, including, but not limited to:

(1) Records demonstrating that the operator training program required by Sec. 63.803(b) is in place;

(2) Records collected in accordance with the inspection and maintenance plan required by Sec. 63.803(c);

(3) Records associated with the cleaning solvent accounting system required by Sec. 63.803(d);

(4) [Reserved]

(5) Records associated with the formulation assessment plan required by Sec. 63.803(l); and

(6) Copies of documentation such as logs developed to demonstrate that the other provisions of the work practice implementation plan are followed.

(f) The owner or operator of an affected source following the compliance method of Sec. 63.804 (f)(4) or (g)(4) shall maintain copies of the calculations demonstrating that the overall control efficiency (R) of the control system results in the value of Eac required by Equations 2 or 4, records of the operating parameter values, and copies of the semiannual compliance reports required by Sec. 63.807(d).

(g) The owner or operator of an affected source following the compliance method of Sec. 63.804 (f)(6) or (g)(6), shall maintain copies of the calculations demonstrating that the overall control efficiency (R) of the control system results in the applicable value of Gac calculated using Equation 3, records of the operating parameter values, and copies of the semiannual compliance reports required by Sec. 63.807(d).

(h) The owner or operator of an affected source subject to the emission limits in Sec. 63.802 and following the compliance provisions of Sec. 63.804(f) (1), (2), (3), (5), (7) and (8) and Sec. 63.804(g) (1), (2), (3), (5), (7), and (8) shall maintain records of the compliance certifications submitted in accordance with Sec. 63.807(c) for each semiannual period following the compliance date.

(i) The owner or operator of an affected source shall maintain records of all other information submitted with the compliance status report required by Sec. 63.9(h) and Sec. 63.807(b) and the semiannual reports required by Sec. 63.807(c).

(j) The owner or operator of an affected source shall maintain all records in accordance with the requirements of Sec. 63.10(b)(1).

(k) The owner or operator of an affected source subject to this subpart shall maintain records of the occurrence and duration of each malfunction of operation (i.e., process equipment) or the air pollution control equipment and monitoring equipment. The owner or operator shall maintain records of actions taken during periods of malfunction to minimize emissions in accordance with Sec. 63.802(c), including corrective actions to restore malfunctioning process and air pollution control and monitoring equipment to its normal or usual manner of operation. [60 FR 62936, Dec. 7, 1995, as amended at 76 FR 72074, Nov. 21, 2011]