Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 63  /  Sec. 63.9570 How do I apply for alternative compliance requirements?

(a) If you use a control technique other than a solvent recovery system and/or solvent substitution, you may request approval to use an alternative method of demonstrating compliance with the emission limitations in Sec. 63.9500(a) and (b) according to the procedures in this section.

(b) You can request approval to use an alternative method of demonstrating compliance in the initial notification for existing sources, the notification of construction or reconstruction for new sources, or at any time.

(c) You must submit a description of the proposed testing, monitoring, recordkeeping, and reporting that will be used and the proposed basis for demonstrating compliance.

(1) If you have not previously performed testing, you must submit a proposed test plan. If you are seeking permission to use an alternative method of compliance based on previously performed testing, you must submit the results of testing, a description of the procedures followed in testing, and a description of pertinent conditions during testing.

(2) You must submit a monitoring plan that includes a description of the control technique, test results verifying the performance of the control technique, the appropriate operating parameters that will be monitored, and the frequency of measuring and recording to establish continuous compliance with the emission limitations in Sec. 63.9500(a) and (b). You must also include the proposed performance specifications and quality assurance procedures for the monitors. The monitoring plan is subject to the Administrator's approval. You must install, calibrate, operate, and maintain the monitors in accordance with the monitoring plan approved by the Administrator.

(d) Use of the alternative method of demonstrating compliance must not begin until approval is granted by the Administrator. Secs. 63.9571-63.9579 [Reserved]

Sec. Table 1 to Subpart QQQQQ of Part 63--Applicability of General

Provisions to Subpart QQQQQ

As required in Sec. 63.9505, you must comply with each applicable General Provisions requirement according to the following table: ----------------------------------------------------------------------------------------------------------------

Citation Subject Applies to subpart QQQQQ? Explanation----------------------------------------------------------------------------------------------------------------Sec. 63.1........................ Applicability........... Yes......................Sec. 63.2........................ Definitions............. Yes......................Sec. 63.3........................ Units and Abbreviations. Yes......................Sec. 63.4........................ Prohibited Activities... Yes......................Sec. 63.5........................ Construction/ Yes......................

Reconstruction.Sec. 63.6(a)-(c), (e)-(f), (i)- Compliance with Yes......................

(j). Standards and

Maintenance

Requirements.Sec. 63.6(d)..................... [Reserved]..............Sec. 63.6(g)..................... Use of an Alternative No....................... Subpart QQQQQ contains

Nonopacity Emission no work practice

Standard. standards.Sec. 63.6(h)..................... Compliance with Opacity No....................... Subpart QQQQQ contains

and Visible Emission no opacity or VE

Standards. limits.Sec. 63.7(a)(1)-(2).............. Applicability and No....................... Subpart QQQQQ includes

Performance Test Dates. dates for initial

compliance

demonstrations.Sec. 63.7(a)(3), (b)-(h)......... Performance Testing No....................... Subpart QQQQQ does not

Requirements. require performance

tests.Sec. 63.8(a)(1)-(2), (b), (c)(1)- Monitoring Requirements. Yes......................

(3), (f)(1)-(5).Sec. 63.8(a)(3).................. [Reserved]..............Sec. 63.8(a)(4).................. Additional Monitoring No....................... Subpart QQQQQ does not

Requirements for require flares.

Control Devices in Sec.

63.11.Sec. 63.8(c)(4).................. Continuous Monitoring No....................... Subpart QQQQQ does not

System (CMS) require CMS.

Requirements.Sec. 63.8(c)(5).................. Continuous Opacity No....................... Subpart QQQQQ does not

Monitoring System require COMS.

(COMS) Minimum

Procedures.Sec. 63.8(c)(6).................. Zero and High Level No....................... Subpart QQQQQ specifies

Calibration Check calibration

Requirements. requirements.Sec. 63.8(c)(7)-(8).............. Out-of-Control Periods.. No....................... Subpart QQQQQ specifies

out-of-control periods

and reporting

requirements.Sec. 63.8(d)..................... CMS Quality Control..... No....................... Subpart QQQQQ requires

a monitoring plan that

specifies CMS quality

control procedures.Sec. 63.8(e)..................... CMS Performance No....................... Subpart QQQQQ does not

Evaluation. require CMS

performance

evaluations.Sec. 63.8(f)(6).................. Relative Accuracy Test No....................... Subpart QQQQQ does not

Audit (RATA) require continuous

Alternative. emissions monitoring

systems (CEMS).Sec. 63.8(g)(1)-(5).............. Data Reduction.......... No....................... Subpart QQQQQ specifies

data reduction

requirements.Sec. 63.9(a)-(d), (h)-(j)........ Notification Yes...................... Except that subpart

Requirements. QQQQQ does not require

performance tests or

CMS performance

evaluations.Sec. 63.9(e)..................... Notification of No....................... Subpart QQQQQ does not

Performance Test. require performance

tests.Sec. 63.9(f)..................... Notification of VE/ No....................... Subpart QQQQQ contains

Opacity Test. no opacity or VE

limits.Sec. 63.9(g)..................... Additional Notifications No....................... Subpart QQQQQ does not

When Using CMS. require CMS

performance

evaluations.Sec. 63.10(a), (b), (d)(1), Recordkeeping and Yes......................

(d)(4)-(5), (e)(3), (f). Reporting Requirements.Sec. 63.10(c)(1)-(6), (9)-(15)... Additional Records for No....................... Subpart QQQQQ specifies

(4)-(5), (e)(3), (f). Reporting Requirements.Sec. 63.10(c)(1)-(6), (9)-(15)... Additional Records for No....................... Subpart QQQQQ specifies

CMS. record requirements.Sec. 63.10(c)(7)-(8)............. Records of Excess No....................... Subpart QQQQQ specifies

Emissions and Parameter record requirements.

Monitoring Exceedances

for CMS.Sec. 63.10(d)(2)................. Reporting Results of No....................... Subpart QQQQQ does not

Performance Tests. require performance

tests.

Sec. 63.10(d)(3)................. Reporting Opacity or VE No....................... Subpart QQQQQ contains

Observations. no opacity or VE

limits.Sec. 63.10(e)(1)-(2)............. Additional CMS Reports.. No....................... Subpart QQQQQ does not

require CMS.Sec. 63.10(e)(4)................. Reporting COMS Data..... No....................... Subpart QQQQQ does not

require COMS.Sec. 63.11....................... Control Device No....................... Subpart QQQQQ does not

Requirements. require flares.Secs. 63.12-63.15................ Delegation, Addresses, Yes......................

Incorporation by

Reference Availability

of Information.---------------------------------------------------------------------------------------------------------------- Subpart RRRRR_National Emission Standards for Hazardous Air Pollutants:

Taconite Iron Ore Processing

Source: 68 FR 61888, Oct. 30, 2003, unless otherwise noted.

What This Subpart Covers