Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 98  /  Sec. 98.473 Calculating CO[bdi2] received.

(a) You must calculate and report the annual mass of CO2 received by pipeline using the procedures in paragraphs (a)(1) or (a)(2) of this section and the procedures in paragraph (a)(3) of this section, if applicable.

(1) For a mass flow meter, you must calculate the total annual mass of CO2 in a CO2 stream received in metric tons by multiplying the mass flow by the CO2 concentration in the flow, according to Equation UU-1 of this section. You must collect these data quarterly. Mass flow and concentration data measurements must be made in accordance with Sec. 98.474.[GRAPHIC] [TIFF OMITTED] TR01DE10.184 where: CO2T,r = Net annual mass of CO2 received through

flow meter r (metric tons).Qr,p = Quarterly mass flow through a receiving flow meter r

in quarter p (metric tons).Sr,p = Quarterly mass flow through a receiving flow meter r

that is redelivered to another facility without being injected

into your well in quarter p (metric tons).CCO2,p,r = Quarterly CO2 concentration measurement

in flow for flow meter r in quarter p (wt. percent

CO2, expressed as a decimal fraction).p = Quarter of the year.r = Receiving flow meter.

(2) For a volumetric flow meter, you must calculate the total annual mass of CO2 in a CO2 stream received in metric tons by multiplying the volumetric flow at standard conditions by the CO2 concentration in the flow and the density of CO2 at standard conditions, according to Equation UU-2 of this section. You must collect these data quarterly. Volumetric flow and concentration data measurements must be made in accordance with Sec. 98.474. [GRAPHIC] [TIFF OMITTED] TR01DE10.185 where: CO2T,r = Net annual mass of CO2 received through

flow meter r (metric tons).Qr,p = Quarterly volumetric flow through a receiving flow

meter r in quarter p at standard conditions (standard cubic

meters).Sr,p = Quarterly volumetric flow through a receiving flow

meter r that is redelivered to another facility without being

injected into your well in quarter p (standard cubic meters).D = Density of CO2 at standard conditions (metric tons per

standard cubic meter): 0.0018682.CCO2,p,r = Quarterly CO2 concentration measurement

in flow for flow meter r in quarter p (vol. percent

CO2, expressed as a decimal fraction).p = Quarter of the year.r = Receiving flow meter.

(3) If you receive CO2 through more than one flow meter, you must sum the mass of all CO2 received in accordance with the procedure specified in Equation UU-3 of this section.[GRAPHIC] [TIFF OMITTED] TR01DE10.186 where: CO2 = Total net annual mass of CO2 received

(metric tons).CO2T,r = Net annual mass of CO2 received (metric

tons) as calculated in Equation UU-1 or UU-2 for flow meter r.r = Receiving flow meter.

(b) You must calculate and report the annual mass of CO2 received in containers using the procedures specified in either paragraph (b)(1) or (b)(2) of this section.

(1) If you are measuring the mass of contents in a container under the provisions of Sec. 98.474(a)(2)(i), you must calculate the CO2 received in containers using Equation UU-1 of this section. where: CO2T,r = Annual mass of CO2 received in containers

r (metric tons).CCO2,p,r = Quarterly CO2 concentration measurement

of contents in containers r in quarter p (wt. percent

CO2, expressed as a decimal fraction).Qr,p = Quarterly mass of contents in containers r in quarter

p (metric tons).Sr,p = Quarterly mass of contents in containers r that is

redelivered to another facility without being injected into

your well in quarter p (standard cubic meters).p = Quarter of the year.r = Containers.

(2) If you are measuring the volume of contents in a container under the provisions of Sec. 98.474(a)(2)(ii), you must calculate the CO2 received in containers using Equation UU-2 of this section. where: CO2T,r = Annual mass of CO2 received in containers

r (metric tons).CCO2,p,r = Quarterly CO2 concentration measurement

of contents in containers r in quarter p (vol. percent

CO2, expressed as a decimal fraction).Sr,p = Quarterly volume of contents in containers r that is

redelivered to another facility without being injected into

your well in quarter p (standard cubic meters).Qr,p = Quarterly volume of contents in containers r in

quarter p (standard cubic meters).D = Density of the CO2 received in containers at standard

conditions (metric tons per standard cubic meter): 0.0018682.p = Quarter of the year.r = Containers. [75 FR 75078, Dec. 1, 2010, as amended at 78 FR 71981, Nov. 29, 2013]