Code of Federal Regulations (alpha)

CFR /  Title 46  /  Part 76  /  Sec. 76.05-1 Fire detecting systems.

(a) On the following vessels, approved fire detecting systems must be installed in the locations indicated by Table 76.05-1(a):

(1) Any vessel on an international voyage;

(2) Any vessel, not on an international voyage, of more than 150 feet in length having sleeping accommodations for passengers; and

(3) Any vessel, not on an international voyage, of 150 feet or less in length that has sleeping accommodations for 50 or more passengers; such vessels are not required to have a detecting system in the cargo spaces.

Table 76.05-1(a)------------------------------------------------------------------------

Fixed

Space Detecting systems extinguishing

systems------------------------------------------------------------------------Safety areas:

Wheelhouse or fire-control None required \1\.. None required.\1\

room.

Stairway and elevator None required \1\.. None required.\1\

enclosures.

Communication corridors.... None required \1\.. None required.\1\

Lifeboat embarkation and None required \1\.. None required.\1\

lowering stations.

Radio room................. None required \1\.. None required.\1\Accommodations:

Staterooms, toilet spaces, None required \1\.. None required.\1\

isolated pantries, etc.

Offices, lockers, and Electric, None required. \1\

isolated storerooms. pneumatic, or

automatic

sprinkling \1\.

Public spaces.............. None required with None required.\1\

20-minute patrol.

Electric,

pneumatic, or

automatic

sprinkling with 1

hour patrol \1\.

Open decks or enclosed None required...... None required.

promenades.Service spaces:

Galleys.................... None required \1\.. None required.\1\

Main pantries.............. None required \1\.. None required.\1\

Motion picture booths and Electric, None required.\1\

film lockers. pneumatic, or

automatic

sprinkling \1 2\.

Paint and lamp rooms....... Smoke detecting \2\ Carbon dioxide \3\

or clean agent

system as

described in 46

CFR subpart

95.16.

Inaccessible baggage, mail, Smoke detecting \2\ Carbon dioxide.\3\

and specie rooms and

storerooms.

Accessible baggage, mail, Electric, None required.\1\

and specie rooms and pneumatic, or

storerooms. automatic

sprinkling.

Refrigerated storerooms.... None required...... None required.

Carpenter, valet, Electric, None required.\1\

photographic, and printing pneumatic, or

shops, sales rooms, etc. automatic

sprinkling.Machinery spaces:

Coal fired boilers: Bunker None required...... None required.\1\

and boiler space.

Oil fired boilers: Spaces None required...... Carbon dioxide or

containing oil fired clean agent

boilers either main or system as

auxiliary, their fuel oil described in 46

service pumps, and/or such CFR subpart 95.16

other fuel oil units as or foam.\4\

the heaters, strainers,

valves, manifolds, etc.,

that are subject to the

discharge pressure of the

fuel oil service pumps,

together with adjacent

spaces to which oil can

drain.

Internal combustion or gas None required...... Carbon dioxide or

turbine propelling clean agent

machinery spaces. system as

described in 46

CFR subpart

95.16.\5\

Electric propulsive motors None required...... None required.

or generators of open type.

Enclosed ventilating None required...... Carbon dioxide or

systems for motors and clean agent

generators of electric system as

propelling machinery. described in 46

CFR subpart 95.16

(in ventilating

system).\6\

Auxiliary spaces, internal None required...... Carbon dioxide or

combustion, or gas turbine. clean agent

system as

described in 46

CFR subpart

95.16.\7\

Auxiliary spaces, electric None required...... None required.

motors, or generators.

Auxiliary spaces, steam.... None required...... None required.

Trunks to machinery spaces. None required...... None required.

Fuel tanks................. None required...... None required.\8\Cargo spaces:

Inaccessible during voyage Smoke detecting.... Carbon dioxide.\3\

(combustible cargo),

including trunks

(excluding tanks).

Accessible during voyage Smoke detecting, Automatic or

(combustible cargo). electric, manual

pneumatic or sprinkling.

automatic

sprinkling.

Vehicular deck (except None required...... Manual sprinkling.

where no overhead deck is

30 feet in length or less).

Cargo oil tanks............ None required...... Carbon dioxide or

foam.\3\

Specially suitable for Smoke detecting, Carbon dioxide,

vehicles. electric, automatic or

pneumatic or manual

automatic sprinkling.

sprinkling.------------------------------------------------------------------------Notes to Table 76.01-5(a)\1\ Vessels of 100 gross tons and over contracted for, on, or before May

27, 1936, and having combustible joiner work must be fitted with an

automatic sprinkling system, except in relatively incombustible

spaces.\2\ On vessels contracted for prior to November 19, 1952, electric or

pneumatic detecting may be substituted.\3\ On vessels contracted for prior to January 1, 1962, a steam

smothering system may be accepted. However, although existing steam

smothering systems may be repaired, replaced, or extended, no new

system contracted for on or after January 1, 1962, will be permitted.\4\ Protection of auxiliary boilers, fuel oil units, valves, and

manifolds are not required on vessels contracted for prior to November

19, 1952.\5\ Not required on vessels less than 300 gross tons (except on an

international voyage) using fuel with a flashpoint higher than 110

[deg]F., where the space is normally manned.\6\ Not required on vessels contracted for prior to November 19, 1952.\7\ Not required on vessels less than 300 gross tons nor on vessels

contracted for prior to November 19, 1952, except when fuel, including

starting fuel, has a flashpoint of 110 [deg]F. or less.\8\ When fuel with a flashpoint of 110 [deg]F. or lower is used, the

space containing the fuel tanks must be protected by a carbon dioxide

or clean agent system as described in 46 CFR subpart 95.16.

(b) The arrangements and details of the fire detecting systems must meet the requirements in 46 CFR subparts 76.25 through 76.33. [USCG-2006-24797, 77 FR 33875, June 7, 2012]