Code of Federal Regulations (alpha)

CFR /  Title 46  /  Part 98  /  Sec. 98.30-12 Stowage of portable tanks and IBCs.

(a) No person may operate a vessel to which this subpart applies unless each portable tank and/or IBC is stowed on an open deck.

(b) No person may stow a portable tank and/or IBC--

(1) In the vicinity of another tank that contains a chemically incompatible product; and

(2) Unless all electrical equipment is explosion-proof or intrinsically safe, as defined in Sec. Sec. 111.105-9 and 111.105-11 of this chapter, in the area of the tank and its associated equipment that is--

(i) Within 10 feet in any horizontal direction; and

(ii) Within 8 feet above the deck.

(c) All IBCs must be secured as specified in 49 CFR 176.74. [CGD 73-172, 39 FR 22954, June 25, 1974, as amended by CGD 84-043, 55 FR 37412, Sept. 11, 1990; 55 FR 47477, Nov. 14, 1990. Redesignated and amended by USCG-2011-0088, 78 FR 54785, 54787, Sept. 6, 2013]