Section 28.10
|
OMB control numbers |
Section 28.20
|
Applicability; preemptive effect |
Section 28.30
|
Incorporation by reference |
Section 28.40
|
Definition of terms used in this part |
Section 28.50
|
Exemption letter |
Section 28.60
|
Termination of unsafe operations |
Section 28.65
|
Approved equipment and material |
Section 28.70
|
Accepted organizations |
Section 28.73
|
Similarly qualified organizations |
Section 28.76
|
Report of casualty |
Section 28.80
|
Report of injury |
Section 28.90
|
Right of appeal |
Section 28.95
|
Applicability |
Section 28.100
|
Lifesaving equipment--general requirements |
Section 28.105
|
Life preservers or other personal flotation devices |
Section 28.110
|
Ring life buoys |
Section 28.115
|
Survival craft |
Section 28.120
|
Stowage of survival craft |
Section 28.125
|
Survival craft equipment |
Section 28.130
|
Lifesaving equipment markings |
Section 28.135
|
Operational readiness, maintenance, and inspection of lifesaving equipment |
Section 28.140
|
Distress signals |
Section 28.145
|
Emergency Position Indicating Radio Beacons (EPIRBs) |
Section 28.150
|
Excess fire detection and protection equipment |
Section 28.155
|
Portable fire extinguishers |
Section 28.160
|
Injury placard |
Section 28.165
|
Applicability |
Section 28.200
|
Fireman's outfits and self-contained breathing apparatus |
Section 28.205
|
First aid equipment and training |
Section 28.210
|
Guards for exposed hazards |
Section 28.215
|
Navigational information |
Section 28.225
|
Compasses |
Section 28.230
|
Anchors and radar reflectors |
Section 28.235
|
General alarm system |
Section 28.240
|
Communication equipment |
Section 28.245
|
High water alarms |
Section 28.250
|
Bilge pumps, bilge piping, and dewatering systems |
Section 28.255
|
Electronic position fixing devices |
Section 28.260
|
Emergency instructions |
Section 28.265
|
Instruction, drills, and safety orientation |
Section 28.270
|
Acceptance criteria for instructors and course curricula |
Section 28.275
|
Applicability and general requirements |
Section 28.300
|
Lifesaving and signaling equipment |
Section 28.305
|
Launching of survival craft |
Section 28.310
|
Fire pumps, fire mains, fire hydrants, and fire hoses |
Section 28.315
|
Fixed gas fire extinguishing systems |
Section 28.320
|
Fire detection systems |
Section 28.325
|
Galley hood and other fire protection equipment |
Section 28.330
|
Fuel systems |
Section 28.335
|
Ventilation of enclosed engine and fuel tank spaces |
Section 28.340
|
Electrical standards for vessels less than 79 feet (24 meters) in length |
Section 28.345
|
General requirements for electrical systems |
Section 28.350
|
Main source of electrical power |
Section 28.355
|
Electrical distribution systems |
Section 28.360
|
Overcurrent protection and switched circuits |
Section 28.365
|
Wiring methods and materials |
Section 28.370
|
Emergency source of electrical power |
Section 28.375
|
General structural fire protection |
Section 28.380
|
Structural fire protection for vessels that operate with more than 49 individuals on board |
Section 28.385
|
Means of escape |
Section 28.390
|
Embarkation stations |
Section 28.395
|
Radar and depth sounding devices |
Section 28.400
|
Hydraulic equipment |
Section 28.405
|
Deck rails, lifelines, storm rails, and hand grabs |
Section 28.410
|
Applicability |
Section 28.500
|
Substantial alterations |
Section 28.501
|
Vessel owner's responsibility |
Section 28.505
|
Definition of stability terms |
Section 28.510
|
Submergence test as an alternative to stability calculations |
Section 28.515
|
Stability instructions |
Section 28.530
|
Inclining test |
Section 28.535
|
Free surface |
Section 28.540
|
Intact stability when using lifting gear |
Section 28.545
|
Icing |
Section 28.550
|
Freeing ports |
Section 28.555
|
Watertight and weathertight integrity |
Section 28.560
|
Water on deck |
Section 28.565
|
Intact righting energy |
Section 28.570
|
Severe wind and roll |
Section 28.575
|
Unintentional flooding |
Section 28.580
|
Applicability |
Section 28.700
|
Examination and certification of compliance |
Section 28.710
|
Survey and classification |
Section 28.720
|
Applicability and general requirements |
Section 28.800
|
Launching of survival craft |
Section 28.805
|
Deck rails, lifelines, storm rails and hand grabs |
Section 28.810
|
Bilge pumps, bilge piping, and dewatering systems |
Section 28.815
|
Fire pumps, fire mains, fire hydrants, and fire hoses |
Section 28.820
|
Excess fire detection and protection equipment |
Section 28.825
|
Fire detection system |
Section 28.830
|
Fuel systems |
Section 28.835
|
Means for stopping pumps, ventilation, and machinery |
Section 28.840
|
General requirements for electrical systems |
Section 28.845
|
Main source of electrical power |
Section 28.850
|
Electrical distribution systems |
Section 28.855
|
Overcurrent protection and switched circuits |
Section 28.860
|
Wiring methods and materials |
Section 28.865
|
Emergency source of electrical power |
Section 28.870
|
Radar, depth sounding, and auto-pilot |
Section 28.875
|
Hydraulic equipment |
Section 28.880
|
Cargo gear |
Section 28.885
|
Examination and certification of compliance |
Section 28.890
|
Loadlines |
Section 28.895
|
Post accident inspection |
Section 28.900
|
Repairs and alterations |
Section 28.905
|
General |
Section 28.1100
|
Request for a waiver |
Section 28.1105
|
Waiver approval |
Section 28.1110
|
Waiver request and approval records |
Section 28.1115
|
Purpose of regulations |