CFR /  Title 10  /  Part 440  /  Sec. 440.30 Administrative review.

(a) An applicant shall have 20 days from the date of receipt of a decision under Sec. 440.12 or Sec. 440.13 to file a notice requesting administrative review. If an applicant does not timely file such a notice, the decision under Sec. 440.12 or Sec. 440.13 shall become final for DOE.

(b) A notice requesting administrative review shall be filed with the Support Office Director and shall be accompanied by a written statement containing supporting arguments and requesting, if desired, the opportunity for a public hearing.

(c) A notice or any other document shall be deemed filed under this section upon receipt.

(d) On or before 15 days from receipt of a notice requesting administrative review which is timely filed, the Support Office Director shall forward to the Deputy Assistant Secretary, the notice requesting administrative review, the decision under Sec. 440.12 or Sec. 440.13 as to which administrative review is sought, a draft recommended final decision for the concurrence of the Deputy Assistant Secretary, and any other relevant material.

(e) If the applicant requests a public hearing, the Deputy Assistant Secretary, within 15 days, shall give actual notice to the State and Federal Register notice of the date, place, time, and procedures which shall apply to the public hearing. Any public hearing under this section shall be informal and legislative in nature.

(f) On or before 45 days from receipt of documents under paragraph (d) of this section or the conclusion of the public hearing, whichever is later, the Deputy Assistant Secretary shall concur in, concur in as modified, or issue a substitute for the recommended decision of the Support Office Director.

(g) On or before 15 days from the date of receipt of the determination under paragraph (f) of this section, the Governor may file an application, with a supporting statement of reasons, for discretionary review by the Assistant Secretary. On or before 15 days from filing, the Assistant Secretary shall send a notice to the Governor stating whether the Deputy Assistant Secretary's determination will be reviewed. If the Assistant Secretary grants review, a decision shall be issued no later than 60 days from the date review is granted. The Assistant Secretary may not issue a notice or decision under this paragraph without the concurrence of the DOE Office of General Counsel.

(h) A decision under paragraph (f) of this section shall be final for DOE if there is no review under paragraph (g) of this section. If there is review under paragraph (g) of this section, the decision thereunder shall be final for DOE, and no appeal shall lie elsewhere in DOE.

(i) Prior to the effective date of the termination of eligibility for further participation in the program because of failure to comply substantially with the requirements of the Act or of this part, a grantee shall have the right to written notice of the basis for the enforcement action and the opportunity for a public hearing notwithstanding any provisions to contrary of 10 CFR 600.26, 600.28(b), 600.29, 600.121(c), and 600.443. A notice under this paragraph shall be mailed by the Support Office Director by registered mail, return-receipt requested, to the State, local grantee, and other interested parties. To obtain a public hearing, the grantee must request an evidentiary hearing, with prior Federal Register notice, in the election letter submitted under Rule 2 of 10 CFR 1024.4 and the request shall be granted notwithstanding any provisions of Rule 2 to the contrary. [55 FR 41326, Oct. 10, 1990, as amended at 58 FR 12529, Mar. 4, 1993]

Sec. Appendix A to Part 440--Standards for Weatherization Materials

The following Government standards are produced by the Consumer Product Safety Commission and are published in title 16, Code of Federal Regulations:

Thermal Insulating Materials for Building Elements Including Walls, Floors, Ceilings, Attics, and Roofs Insulation--organic fiber--conformance to Interim Safety Standard in 16 CFR part 1209;

Fire Safety Requirements for Thermal Insulating Materials According to Insulation Use--Attic Floor--insulation materials intended for exposed use in attic floors shall be capable of meeting the same flammability requirements given for cellulose insulation in 16 CFR part 1209;

Enclosed spaces--insulation materials intended for use within enclosed stud or joist spaces shall be capable of meeting the smoldering combustion requirements in 16 CFR part 1209.

The following standards which are not otherwise set forth in part 440 are incorporated by reference and made a part of part 440. The following standards have been approved for incorporation by reference by the Director of the Federal Register in accordance with 5 U.S.C. 552(a) and 1 CFR part 51. These materials are incorporated as they exist on April 5, 1993 and a notice of any change in these materials will be published in the Federal Register. The standards incorporated by reference are available for inspection at the National Archives and Records Administration (NARA). For information on the availability of this material at NARA, call 202-741-6030, or go to: http://www.archives.gov/federal--register/code--of--federal--regulations/ibr--locations.html.

The standards incorporated by reference in part 440 can be obtained from the following sources: Air Conditioning and Refrigeration Institute, 1501 Wilson Blvd., Arlington, VA 22209; (703) 524-8800.American Gas Association, 1515 Wilson Blvd., Arlington, VA 22209; (703) 841-8400.American National Standards Institute, Inc., 1430 Broadway, New York, NY 10018; (212) 642-4900.American Society of Mechanical Engineers, United Engineering Center, 345 East 47th Street, New York, NY 10017; (212) 705-7800.American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103; (215) 299-5400.American Architectural Manufacturers Association, 1540 East Dundee Road, Palatine, IL 60067; (708) 202-1350.Federal Specifications, General Services Administration, Specifications Section, Room 6654, 7th and D Streets, SW, Washington, DC 20407; (202) 708-5082.Gas Appliance Manufacturers Association, 1901 Moore St., Arlington, VA 22209; (703) 525-9565.National Electrical Manufacturers Association, 2101 L Street, NW, Suite 300, Washington, DC 20037; (202) 457-8400.National Fire Protection Association, Batterymarch Park, P.O. Box 9101, Quincy, MA 02269; (617) 770-3000.National Standards Association, 1200 Quince Orchard Blvd., Gaithersburg, MD 20878; (301) 590-2300. (NSA is a local contact for materials from ASTM).National Wood Window and Door Association, 1400 East Touhy Avenue, Des Plaines, IL 60018; (708) 299-5200.Sheet Metal and Air Conditioning Contractors Association, P.O. Box 221230, Chantilly, VA 22022-1230; (703) 803-2980.Steel Door Institute, 712 Lakewood Center North, 14600 Detroit Avenue, Cleveland, OH 44107; (216) 899-0100.Steel Window Institute, 1230 Keith Building, Cleveland, OH 44115; (216) 241-7333.Tubular Exchanger Manufacturers Association, 25 North Broadway, Tarrytown, NY 10591; (914) 332-0040.Underwriters Laboratories, Inc., P.O. Box 75530, Chicago, IL 60675-5330; (708) 272-8800.

More information regarding the standards in this reference can be obtained from the following sources: Environmental Protection Agency, 401 M Street, NW, Washington, DC 20006; (202) 554-1080.National Institute of Standards and Technology, U.S. Department of Commerce, Gaithersburg, MD 20899, (301) 975-2000Weatherization Assistance Programs Division, Conservation and Renewable Energy, Mail Stop 5G-023, Forrestal Bldg, 1000 Independence Ave, SW, Washington, DC 20585; (202) 586-2207.

Thermal Insulating Materials for Building Elements Including Walls,

Floors, Ceilings, Attics, and Roofs

[Standards for conformance]

------------------------------------------------------------------------Insulation--mineral fiber:

Blanket insulation.............................. ASTM \1\ C665-88.

Roof insulation board........................... ASTM C726-88.

Loose-fill insulation........................... ASTM C764-88.Insulation--mineral cellular:

Vermiculite loose-fill insulation............... ASTM C516-80 (1990).

Perlite loose-fill insulation................... ASTM C549-81 (1986).

Cellular glass insulation block................. ASTM C552-88.

Perlite insulation board........................ ASTM C728-89a.Insulation--organic fiber:

Cellulosic fiber insulating board............... ASTM C208-72 (1982).

Cellulose loose-fill insulation................. ASTM C739-88.Insulation-organic cellular:

Preformed block-type polystyrene insulation..... ASTM C578-87a.

Rigid preformed polyurethane insulation board... ASTM C591-85.

Polyurethane or polyisocyanurate insulation FS \2\ HH-I-1972/1

board faced with aluminum foil on both sides. (1981).

Polyurethane or polyisocyanurate insulation FS HH-I-1972/2

board faced with felt on both sides. (1981). And

Amendment 1,

October 3, 1985.Insulation--composite boards:

Mineral fiber and rigid cellular polyurethane ASTM C726-88.

composite roof insulation board.

Perlite board and rigid cellular polyurethane ASTM C984-83.

composite roof insulation.

Gypsum board and polyurethane or polisocyanurate FS HH-I-1972/4

composite board. (1981).

Materials used as a patch to reduce infiltration Commercially

through the building envelope. available.------------------------------------------------------------------------\1\ ASTM indicates American Society for Testing and Materials.\2\ FS indicates Federal Specifications.

Thermal Insulating Materials for Pipes, Ducts, and Equipment Such as

Boilers and Furnaces

[Standards for conformance]

------------------------------------------------------------------------Insulation--mineral fiber:

Preformed pipe insulation............ ASTM \1\ C547-77.

Blanket and felt insulation ASTM C553-70 (1977).

(industrial type).

Blanket insulation and blanket type ASTM C592-80.

pipe insulation (metal-mesh covered)

(industrial type).

Block and board insulation........... ASTM C612-83.

Spray applied fibrous insulation for ASTM C720-89.

elevated temperature.

High-temperature fiber blanket ASTM C892-89.

insulation.

Duct work insulation................. Selected and applied according

to ASTM C971-82.Insulation--mineral cellular:

Diatomaceous earth block and pipe ASTM C517-71 (1979)

insulation.

Calcium silicate block and pipe ASTM C533-85 (1990).

insulation.

Cellular glass insulation............ ASTM C552-88.

Expanded perlite block and pipe ASTM C610-85.

insulation.Insulation--Organic Cellular:

Preformed flexible elastomeric ASTM C534-88.

cellular insulation in sheet and

tubular form.

Unfaced preformed rigid cellular ASTM C591-85.

polyurethane insulation.Insulation skirting.................... Commercially available.------------------------------------------------------------------------\1\ ASTM indicates American Society for Testing and Materials.

Fire Safety Requirements for Insulating Materials According to

Insulation Use

[Standards for conformance]

------------------------------------------------------------------------Attic floor....................... Insulation materials intended for

exposed use in attic floors shall

be capable of meeting the same

smoldering combustion requirements

given for cellulose insulation in

ASTM \1\ C739-88.Enclosed space.................... Insulation materials intended for

use within enclosed stud or joist

spaces shall be capable of meeting

the smoldering combustion

requirements in ASTM C739-88.Exposed interior walls and Insulation materials, including

ceilings. those with combustible facings,

which remain exposed and serve as

wall or ceiling interior finish,

shall have a flame spread

classification not to exceed 150

(per ASTM E84-89a).Exterior envelope walls and roofs. Exterior envelope walls and roofs

containing thermal insulations

shall meet applicable local

government building code

requirements for the complete wall

or roof assembly.Pipes, ducts, and equipment....... Insulation materials intended for

use on pipes, ducts and equipment

shall be capable of meeting a flame

spread classification not to exceed

150 (per ASTM E84-89a).------------------------------------------------------------------------\1\ ASTM indicates American Society for Testing and Materials.

Storm Windows

[Standards for conformance]

------------------------------------------------------------------------Storm windows:

Aluminum insulating storm windows.. ANSI/AAMA \1\1002.10-83.

Aluminum frame storm windows....... ANSI/AAMA 1002.10-83.

Wood frame storm windows........... ANSI/NWWDA \2\ I.S. 2-87.

(Section 3)

Rigid vinyl frame storm windows.... ASTM \3\ D4099-89.

Frameless plastic glazing storm.... Required minimum thickness

windows is 6 mil (.006 inches).Movable insulation systems for Commercially available.

windows.------------------------------------------------------------------------\1\ ANSI/AAMA indicates American National Standards Institute/American

Architectural Manufacturers Association.\2\ ANSI/NWWDA indicates American National Standards Institute/National

Wood Window & Door Association.\3\ ASTM indicates American Society for Testing and Materials.

Storm Doors

[Standards for conformance]

------------------------------------------------------------------------Storm doors--Aluminum:

Storm Doors........................ ANSI/AAMA \1\ 1102.7-89.

Sliding glass storm doors.......... ANSI/AAMA 1002.10-83.

Wood storm doors..................... ANSI/NWWDA \2\ I.S. 6-86.Rigid vinyl storm doors.............. ASTM \3\ D3678-88.Vestibules:

Materials to construct vestibules.. Commercially available.Replacement windows:

Aluminum frame windows............. ANSI/AAMA 101-88.

Steel frame windows................ Steel Window Institute

recommended specifications for

steel windows, 1990.

Wood frame windows................. ANSI/NWWDA I.S. 2-87.

Rigid vinyl frame windows.......... ASTM D4099-89.------------------------------------------------------------------------\1\ ANSI/AAMA indicates American National Standards Institute/American

Architectural Manufacturers Association.\2\ ANSI/NWWDA indicates American National Standards Institute/National

Wood Window & Door Association.\3\ ASTM indicates American Society for Testing and Materials.

Replacement Doors

[Standards for conformance]

------------------------------------------------------------------------Replacement doors--Hinged doors:

Steel doors.......................... ANSI/SDI \1\ 100-1985.Wood doors:

Flush doors.......................... ANSI/NWWDA \2\ I.S. 1-87.

(exterior door provisions)

Pine, fir, hemlock and spruce doors.. ANSI/NWWDA I.S. 6-86.Sliding patio doors:

Aluminum doors....................... ANSI/AAMA \3\ 101-88.

Wood doors........................... NWWDA I.S. 3-83.------------------------------------------------------------------------\1\ ANSI/SDI indicates American National Standards Institute/Steel Door

Institute.\2\ ANSI/NWWDA indicates American National Standards Institute/National

Wood Window & Door Association.\3\ ANSI/AAMA indicates American National Standards Institute/American

Architectural Manufacturers Association.

Caulks and sealants:

[Standards for conformance]

------------------------------------------------------------------------Caulks and sealants:

Putty.............................. FS \1\ TT-P-00791B, October 16,

1969 and Amendment 2, March 23,

1971.

Glazing compounds for metal sash... ASTM \2\ C669-75 (1989).

Oil and resin base caulks.......... ASTM C570-72 (1989).

Acrylic (solvent types) sealants... FS TT-S-00230C, February 2, 1970

and Amendment 2, October 9,

1970.

Butyl rubber sealants.............. FS TT-S-001657, October 8, 1970.

Chlorosulfonated polyethylene FS TT-S-00230C, February 2, 1970

sealants. and Amendment 2, October 9,

1970.

Latex sealing compounds............ ASTM C834-76 (1986).

Elastomeric joint sealants ASTM C920-87.

(normally considered to include

polysulfide, polyurethane, and

silicone).

Preformed gaskets and sealing ASTM C509-84.

materials.------------------------------------------------------------------------\1\ FS indicates Federal Specifications.\2\ ASTM indicates American Society for Testing and Materials.

Weatherstripping

[Standards for conformance]

------------------------------------------------------------------------Weatherstripping.................. Commercially available.Vapor retarders................... Selected according to the provisions

cited in ASTM \1\ C755-85 (1990).

Permeance not greater than 1 perm

when determined according to the

desiccant method de- scribed in

ASTM E96-90.Items to improve attic ventilation Commercially available.Clock thermostats................. NEMA \2\ DC 3-1989.------------------------------------------------------------------------\1\ ASTM indicates American Society for Testing and Materials.\2\ NEMA indicates National Electrical Manufacturers Association.

Heat Exchangers

[Standards for conformance]

------------------------------------------------------------------------Heat exchangers, water-to-water ASME \1\ Boiler and Pressure Vessel

and steam-to-water. Code, 1992, Sections II, V, VIII,

IX, and X, as applicable to

pressure vessels. Standards of

Tubular Exchanger Manufacturers

Association, Seventh Edition, 1988.Heat exchangers with gas-fired Conformance to AGA \3\ Requirements

appliances \2\. for Heat Reclaimer Devices for Use

with Gas-Fired Appliances No. 1-80,

June 1, 1980. AGA Laboratories

Certification Seal.

Heat pump water heating heat Electrical components to be listed

recovery systems. by UL. \4\------------------------------------------------------------------------\1\ ASME indicates American Society of Mechanical Engineers.\2\ The heat reclaimer is for installation in a section of the vent

connector from appliances equipped with draft hoods or appliances

equipped with powered burners or induced draft and not equipped with a

draft hood.\3\ AGA indicates American Gas Association.\4\ UL indicates Underwriters Laboratories.

Boiler/Furnace Control Systems

[Standards for conformance]

------------------------------------------------------------------------Automatic set back thermostats......... Listed by UL. \1\ Conformance

to NEMA \2\ DC 3-1989.Line voltage or low voltage room NEMA DC 3-1989.

thermostats.Automatic gas ignition systems......... ANSI \3\ Z21.21-1987 and

Z21.21a-1989. AGA \4\

Laboratories Certification

Seal.Energy management systems.............. Listed by UL.Hydronic boiler controls............... Listed by UL.Other burner controls.................. Listed by UL.------------------------------------------------------------------------\1\ UL indicates Underwriters Laboratories.\2\ NEMA indicates National Electrical Manufacturers Association.\3\ ANSI indicates American National Standards Institute.\4\ AGA indicates American Gas Association.

Water Heater Modifications

[Standards for conformance]

------------------------------------------------------------------------Insulate tank and distribution piping (See insulation section of this

appendix).Install heat traps on inlet and Applicable local plumbing code.

outlet piping.Install/replace water heater heating Listed by UL. \1\

elements.Electric, freeze-prevention tape for Listed by UL.

pipes.Reduce thermostat settings........... State or local recommendations.Install stack damper, gas-fueled..... ANS1 \2\ Z21.66-1988, including

Exhibits A&B;, and ANSI Z223.1-

1988.Install stack damper, oil-fueled..... UL 17, November 28, 1988, and

NFPA \3\ 31-1987.Install water flow modifiers......... Commercially available.------------------------------------------------------------------------\1\ UL indicates Underwriters Laboratories.\2\ ANSI indicates American National Standards Institute.\3\ NFPA indicates National Fire Prevention Association.

Waste Heat Recovery Devices

[Standards for conformance]

------------------------------------------------------------------------Desuperheater/water heaters....... ARI \1\ 470-1987.Condensing heat exchangers........ Commercially available components

and in new heating furnace systems

to manufacturers' specifications.Condensing heat exchangers........ Commercially available (Commercial,

multi-story building, with teflon-

lined tubes institutional) to

manufacturers' specifications.Energy recovery equipment......... Energy Recovery Equipment and

Systems Air-to-Air (1978) Sheet

Metal and Air-Conditioning

Contractors National Association

(SMACNA). \2\------------------------------------------------------------------------\1\ ARI indicates Air Conditioning and Refrigeration Institute.\2\ SMACNA denotes Sheet Metal and Air Conditioning Contractors'

National Association.

Boiler Repair and Modifications/Efficiency Improvements

[Standards for conformance]

------------------------------------------------------------------------Install gas conversion burners......... ANSI \1\ Z21.8-1984, (for gas

or oil-fired systems) ANSI

Z21.17-1984, ANSI Z21.17a-

1990, and ANSI Z223.1-1988.

AGA \2\ Laboratories

Certification seal.Replace oil burner UL \3\ 296, February 28, 1989

Revision and NFPA \4\ 31-1987.Install burners (oil/gas) ANSI Z223.1-1988 for gas

equipment and NFPA 31-1987 for

oil equipment.Re-adjust boiler water temperature or ASME \5\ CSD-1-1988, ASME CSD-

install automatic boiler temperature 1a-1989, ANSI Z223.1-1988, and

reset control. NFPA 31-1987.Replace/modify boilers ASME Boiler and Pressure Vessel

Code, 1992, Sections II, IV,

V, VI, VIII, IX, and X.

Boilers must be Institute of

Boilers and Radiation

Manufacturers (IBR) equipment.Clean heat exchanger, adjust burner air Per manufacturers'

shutter(s), check smoke no. on oil- instructions.

fueled equipment. Check operation of

pump(s) and replacement filters.Repair combustion chambers............. Refractory linings may be

required for conversions.

Replace heat exchangers, tubes......... Protection from flame contact

with conversion burners by

refractory shield.Install/replace thermostatic radiator Commercially available. One

valves. pipe steam systems require air

vents on each radiator; see

manufacturers' requirements.Install boiler duty cycle control Commercially available. NFPA

system. 70, National Electrical Code

(NEC) 1993 and local

electrical codes provisions

for wiring.------------------------------------------------------------------------\1\ ANSI indicates American National Standards Institute.\2\ AGA indicates American Gas Association.\3\ UL indicates Underwriters Laboratories.\4\ NFPA indicates National Fire Prevention Association.\5\ ANSI/ASME indicates American National Standards Institute/American

Society of Mechanical Engineers.

Heating and Cooling System Repairs and Tune-ups/Efficiency Improvements

[Standards for conformance]

------------------------------------------------------------------------Install duct insulation................ FS \1\ HH-I-558C, January 7,

1992 (see insulation sections

of this appendix).Reduce input of burner; derate gas- Local utility company and

fueled equipment. procedures if applicable for

gas-fueled furnaces and ANSI

\2\ Z223.1-1988 (NFPA \3\ 54-

1988) including appendix H.Repair/replace oil-fired equipment..... NFPA 31-1987.Replace combustion chamber in oil-fired NFPA 31-1987.

furnaces or boilers.Clean heat exchanger and adjust burner: ANSI Z223.1-1988 (NFPA 54-1988)

adjust air shutter and check CO2 and including appendix H.

stack temperature. Clean or replace

air filter on forced air furnace.Install vent dampers for gas-fueled Applicable sections of ANSI

heating systems. Z223.1-1988 (NFPA 54-1988)

including appendices H, I, J,

and K. ANSI Z21.66-1988 and

exhibits A & B for

electrically operated dampers.Install vent dampers for oil-fueled Applicable sections of NFPA 31-

heating systems. 1987 for installation and in

conformance with UL \4\ 17,

November 28, 1988.Reduce excess combustion air:

A: Reduce vent connector size of gas- ANSI Z223.1-1988 (NFPA 54-1988)

fueled appliances. part 9 and appendices G & H.

B: Adjust barometric draft regulator NFPA 31-1987 and per

for oil fuels. manufacturers' (furnace or

boiler) instructions.Replace constant burning pilot with ANSI Z21.71-1981, Z21.71a-1985,

electric ignition device on gas-fueled and Z21.71b-1989.

furnaces or boilers.Readjust fan switch on forced air gas Applicable sections and

or oil-fueled furnaces. appendix H of ANSI Z223.1-1988

(NFPA 54-1988) for gas

furnaces and NFPA 31-1987 for

oil furnaces.Replace burners........................ See power burners (oil/gas).Install/replace duct furnaces (gas).... ANSI Z223.1-1988 (NFPA 54-

1988).Install/replace heat pumps............. Listed by UL.Replace air diffusers, intakes, Commercially available.

registers, and grilles.Install/replace warm air heating metal Commercially available.

ducts.Filter alarm units..................... Commercially available.------------------------------------------------------------------------\1\ FS indicates Federal Specifications.\2\ ANSI indicates American National Standards Institute.\3\ NFPA indicates National Fire Prevention Association.\4\ UL indicates Underwriters Laboratories.

Replacement Furnaces, Boilers, and Wood Stoves

[Standards for conformance]

------------------------------------------------------------------------Chimneys, fireplaces, vents and solid NFPA \1\ 211-1988.

fuel burning appliances.Gas-fired furnaces..................... ANS1 \2\ Z21.47-1987, Z21.47a-

1988, and Z21.47b-1989. ANSI

Z223.1-1988 (NFPA 54-1988).Oil-fired furnaces..................... UL \3\ 727, August 27, 1991

Revision and NFPA 31-1987.Liquified petroleum gas storage........ NFPA 58-1989.Ventilation fans:

Including electric attic, ceiling, UL 507, August 23, 1990

and whole house fans. Revision.------------------------------------------------------------------------\1\ NFPA indicates National Fire Prevention Association.\2\ ANSI indicates American National Standards Institute.\3\ UL indicates Underwriters Laboratories.

Air Conditioners and Cooling Equipment

[Standards for conformance]

------------------------------------------------------------------------Air conditioners:

Central air conditioners................... ARI \1\ 210/240-1989.

Room size units............................ ANSI/AHAM \2\ RAC-1-1982.Other cooling equipment:

Including evaporative coolers, heat pumps UL \3\ 1995, November 30,

and other equipment. 1990. \4\------------------------------------------------------------------------\1\ ARI indicates Air Conditioning and Refrigeration Institute.\2\ AHAM/ANSI indicates American Home Appliance Manufacturers/American

National Standards Institute.\3\ UL indicates Underwriters Laboratories.\4\ This standard is a general standard covering many different types of

heating and cooling equipment.

Screens, Window Films, and Reflective Materials

[Standards for conformance]

------------------------------------------------------------------------Insect screens............................... Commercially available.Window films................................. Commercially available.Shade screens:

Fiberglass shade screens................... Commercially available.

Polyester shade screens.................... Commercially available.Rigid awnings:

Wood rigid awnings......................... Commercially available.

Metal rigid awnings........................ Commercially available.Louver systems:

Wood louver systems........................ Commercially available.

Metal louver systems....................... Commercially available.Industrial-grade white paint used as a heat- Commercially available.

reflective measure on awnings, window

louvers, doors, and exterior duct work

(exposed).------------------------------------------------------------------------ [58 FR 12529, Mar. 4, 1993, as amended at 69 FR 18803, Apr. 9, 2004]