No position light intensity may exceed the applicable values in the following table, except as provided in Sec. 25.1389(b)(3). ------------------------------------------------------------------------
Maximum intensity
-----------------------
Overlaps Area A Area B
(candles) (candles)------------------------------------------------------------------------Green in dihedral angle L....................... 10 1Red in dihedral angle R......................... 10 1Green in dihedral angle A....................... 5 1Red in dihedral angle A......................... 5 1Rear white in dihedral angle L.................. 5 1Rear white in dihedral angle R.................. 5 1------------------------------------------------------------------------ Where--
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and
(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20 degrees.