Code of Federal Regulations (alpha)

CFR /  Title 33  /  Part 183  /  Sec. 183.114 Test of flotation materials.

(a) Vapor test. The flotation material must not reduce in buoyant force more than 5 percent after being immersed in a fully saturated gasoline vapor atmosphere for 30 days at a minimum temperature of 38 C.

(b) 24-hour gasoline test. The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 24 hours at 23 plus or minus 2 C in reference fuel B, of ASTM D 471 (incorporated by reference, see Sec. 183.5).

(c) 30-day gasoline test. The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 30 days at 23 plus or minus 2 C in reference fuel B, of ASTM D 471 (incorporated by reference, see Sec. 183.5).

(d) 24-hour oil test. The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 24 hours at 23 plus or minus 2 C in reference oil No. 2, of ASTM D 471 (incorporated by reference, see Sec. 183.5).

(e) 30-day oil test. The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 30 days at 23 plus or minus 2 C in reference oil No. 2, of ASTM D 471 (incorporated by reference, see Sec. 183.5).

(f) 24-hour bilge cleaner test. The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 24 hours at 23 plus or minus 2 C in a 5-percent solution of trisodium phosphate in water.

(g) 30-day bilge cleaner test. The flotation material must not reduce in buoyant force more than 5 percent after being immersed for 30 days at 23 plus or minus 2 C in a 5-percent solution of trisodium phosphate in water.

(h) The buoyant force reduction in paragraphs (a) through (g) of this section is measured in accordance with ASTM D 2842 (incorporated by reference, see Sec. 183.5).

Table 183.114--Flotation Performance Tests------------------------------------------------------------------------

Area 183.110

-------------------------------

(c) Engine

Test 183.114 (b) room

Engine unless (d)

room open to Bilge

(a) Vapor test.......................... ........ X ........(b) 24 hour gasoline test............... ........ .......... X(c) 30 day gasoline test................ X .......... ........(d) 24 hour oil test.................... ........ .......... X(e) 30 day oil test..................... X .......... ........(f) 24 hour bilge cleaner test.......... ........ .......... X(g) 30 day bilge cleaner test........... X .......... ........------------------------------------------------------------------------ [CGD 77-145, 43 FR 56859, Dec. 4, 1978; 44 FR 47934, Aug. 16, 1979, as amended by USCG-2000-7223, 65 FR 40059, June 29, 2000] Subpart G_Flotation Requirements for Outboard Boats Rated for Engines of

More Than 2 Horsepower

Source: CGD 75-168, 42 FR 20243, Apr. 18, 1977, unless otherwise noted.