CFR /  Title 40  /  Part 1066  /  Sec. 1066.130 Measurement instrument calibrations and verifications.

The measurement instrument calibration and verification requirements in 40 CFR part 1065, subpart D, apply with the following exceptions:

(a) The calibration and verification provisions of 40 CFR 1065.303 do not apply for engine speed, torque, fuel rate, or intake air flow.

(b) The linearity verification provisions of 40 CFR 1065.307 do not apply for engine speed, torque, fuel rate, or intake air flow. Section 1066.135 specifies additional linearity verification provisions that apply specifically for chassis testing.

(c) The provisions of Sec. 1066.220 apply instead 40 CFR 1065.310.

(d) The provisions of 40 CFR 1065.320, 1065.325, and 1065.395 do not apply.

(e) If you are measuring flow volumetrically (rather than measuring based on molar values), the provisions of Sec. 1066.140 apply instead of 40 CFR 1065.340.

(f) The provisions of Sec. 1066.150 apply instead 40 CFR 1065.350(c), 1065.355(c), 1065.370(c), and 1065.375(c).

(g) Table 1 of this section summarizes the required and recommended calibrations and verifications that are unique to testing under this part and indicates when these must be performed. Perform other required or recommended calibrations and verifications as described in 40 CFR 1065.303, with the exceptions noted in this section. Table 1 follows:

Table 1 of Sec. 1066.130--Summary of Required Calibrations and

Verifications------------------------------------------------------------------------

Type of calibration or

verification Minimum frequency \a\------------------------------------------------------------------------40 CFR 1065.307: Linearity The linearity verifications from 40

verification. CFR part 1065 do not apply under

this part for engine speed, torque,

fuel rate, or intake air flow; the

linearity verification described in

Sec. 1066.135 applies for the

following measurements:

Dynamometer speed: See Sec.

1066.220.

Dynamometer torque: See Sec.

1066.220.

40 CFR 1065.310: Torque........... This calibration does not apply for

testing under this part; see Sec.

1066.220.40 CFR 1065.320: Fuel flow........ This calibration does not apply for

testing under this part.40 CFR 1065.325: Intake flow...... This calibration does not apply for

testing under this part.40 CFR 1065.340: CVS calibration.. This calibration does not apply for

CVS flow meters calibrated

volumetrically as described in Sec.

1066.140.40 CFR 1065.345: Vacuum leak...... Required upon initial installation

of the sampling system; recommended

within 35 days before the start of

an emissions test and after

maintenance such as pre-filter

changes.40 CFR 1065.350(c), 1065.355(c), These provisions do not apply for

1065.370(c), and 1065.375(c). testing under this part; see Sec.

1066.150.40 CFR 1065.395: Inertial PM These verifications do not apply for

balance and weighing. testing under this part.------------------------------------------------------------------------\a\ Perform calibrations and verifications more frequently if needed to

conform to the measurement system manufacturer's instructions and good

engineering judgment.