Except as provided in Secs. 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
(a) For whey condensing plants with over 300,000 lb/day of fluid raw whey input (over 20,700 lb/day of solids or 14,160 lb/day of BOD5 input). ------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed--------------------------------------------------------------------------
Metric units (kilograms per
1,000 kg of BOD5 input)
-------------BOD5...................................... 1.00 0.400TSS....................................... 1.50 .600pH........................................ (\1\) (\1\)
-------------
English units (pounds per
100 lb of BOD5 input)
-------------BOD5...................................... 0.100 0.040TSS....................................... 0.150 .060pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
(b) For whey condensing plants with 300,000 lb/day or less of raw fluid whey input (less than 20,700 lb/day of solids or 14,160 lb/day of BOD5 input). ------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed--------------------------------------------------------------------------
Metric units (kilograms per
1,000 kg of BOD5 input)
-------------BOD5...................................... 1.30 0.650TSS....................................... 1.950 .975pH........................................ (\1\) (\1\)
-------------
English units (pounds per
100 lb of BOD5 input)
-------------BOD5...................................... 0.130 0.065TSS....................................... 0.195 .098pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
(c) For plants in the size range covered in paragraph (b) once-through barometric condenser water may be discharged untreated if the composite net entrainment is below 15 mg/1 of BOD5 for any one day and below 10 mg/1 of BOD5 as the average for thirty consecutive days. [39 FR 18597, May 28, 1974, as amended at 60 FR 33935, June 29, 1995] Sec. 405.113 [Reserved]