Except as provided in Secs. 125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): ------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed--------------------------------------------------------------------------
Metric units (kg/kkg of
seafood)
-------------TSS....................................... 12 12Oil and grease............................ 1.3 0.42pH........................................ (\1\) (\1\)
-------------
English units (lb/1,000 lb
of seafood)
-------------TSS....................................... 12 3.9Oil and grease............................ 1.3 0.42pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0. [39 FR 23140, June 26, 1974, as amended at 60 FR 33941, June 29, 1995] Sec. 408.63 [Reserved]