(a) Any new source subject to this subpart must achieve the following new source performance standards (NSPS): ------------------------------------------------------------------------
NSPS effluent
limitations
------------------------
Average of
daily
Pollutant or pollutant property Maximum values for
for any 1 30
day consecutive
days shall
not exceed------------------------------------------------------------------------
Metric units (kilograms
per 1,000 m\3\ of
feedstock)
-------------BOD5........................................... 16.3 8.7TSS............................................ 11.3 7.2COD \1\........................................ 118.0 61oil and grease................................. 4.8 2.6Phenolic compounds............................. 0.119 0.058Ammonia (as N)................................. 18.8 8.6Sulfide........................................ 0.105 0.048Total chromium................................. 0.24 0.14Hexavalent chromium............................ 0.020 0.0088pH............................................. (\2\) (\2\)
-------------
English units (pounds
per 1,000 bbl of
feedstock)
-------------BOD5........................................... 5.8 3.1TSS............................................ 4.0 2.5COD \1\........................................ 41.5 21Oil and grease................................. 1.7 0.93Phenolic compounds............................. 0.042 0.020Ammonia (as N)................................. 6.6 3.0Sulfide........................................ 0.037 0.017Total chromium................................. 0.084 0.049Hexavalent chromium............................ 0.0072 0.0032pH............................................. (\2\) (\2\)------------------------------------------------------------------------\1\ See footnote following table in Sec. 419.13(d).\2\ Within the range 6.0 to 9.0.
(b) The limits set forth in paragraph (a) of this section are to be multiplied by the following factors to calculate the maximum for any 1 day and maximum average of daily values for 30 consecutive days.
(1) Size Factor. ------------------------------------------------------------------------
Size
1,000 bbl of feedstock per stream day factor------------------------------------------------------------------------Less than 24.9............................................... 0.9125.0 to 49.9................................................. 0.9550.0 to 74.9................................................. 1.0475.0 to 99.9................................................. 1.13100.0 to 124.9............................................... 1.23125.0 to 149.9............................................... 1.35150.0 or greater............................................. 1.41------------------------------------------------------------------------
(2) Process factor. ------------------------------------------------------------------------
Process
Process configuration factor------------------------------------------------------------------------Less than 2.49............................................... 0.582.5 to 3.49.................................................. 0.633.5 to 4.49.................................................. 0.744.5 to 5.49.................................................. 0.885.5 to 5.99.................................................. 1.006.0 to 6.49.................................................. 1.096.5 to 6.99.................................................. 1.197.0 to 7.49.................................................. 1.297.5 to 7.99.................................................. 1.418.0 to 8.49.................................................. 1.538.5 to 8.99.................................................. 1.679.0 to 9.49.................................................. 1.829.5 or greater............................................... 1.89------------------------------------------------------------------------
(3) See the comprehensive example in subpart D, Sec. 419.42(b)(3).
(c) The provisions of Sec. 419.16(c) apply to discharges of process wastewater pollutants attributable to ballast water by a point source subject to the provisions of this subpart.
(d) The quantity and quality of pollutants or pollutant properties controlled by this paragraph, attributable to once-through cooling water, are excluded from the discharge allowed by paragraph (b) of this section. Once-through cooling water may be discharged with a total organic carbon concentration not to exceed 5 mg/l.
(e) Effluent limitation for runoff. [Reserved] [47 FR 46446, Oct. 18, 1982, as amended at 50 FR 28523, July 12, 1985; 50 FR 32414, Aug. 12, 1985]