The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this section, which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: ------------------------------------------------------------------------
Effluent limitations
-----------------------------
Average of daily
Effluent characteristic Maximum values for 30
for any 1 consecutive days
day shall not
exceed--------------------------------------------------------------------------
Metric units (kg/kkg of raw
material)
-----------------------------Zinc...................................... 0.058 0.024BOD5...................................... 2.4 1.4TSS....................................... 2.26 0.94pH........................................ (\1\) (\1\)
-----------------------------
English units (lb/1,000 lb
of raw material)
-----------------------------Zinc...................................... 0.058 0.024BOD5...................................... 2.4 1.4TSS....................................... 2.26 0.94pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0. Sec. 428.114 [Reserved]