Any source that is a new source subject to this subpart must achieve the following performance standards:
(a) Facilities that slaughter no more than 100 million pounds per year (in units of LWK) must achieve the following performance standards:
Performance Standards
[NSPS]------------------------------------------------------------------------
Maximum
Regulated parameter Maximum monthly
daily \1\ avg. \1\------------------------------------------------------------------------Ammonia (as N)................................ 8.0 4.0BOD5.......................................... 26 16Fecal Coliform................................ ( \2\ ) ( \3\ )O&G; (as HEM).................................. 14 8.0TSS........................................... 30 20------------------------------------------------------------------------\1\ mg/L (ppm).\2\ Maximum of 400 MPN or CFU per 100 mL at any time.\3\ No maximum monthly average limitation.
(b) Facilities that slaughter more than 100 million pounds per year (in units of LWK) must achieve the following performance standards:
Performance Standards
[NSPS]------------------------------------------------------------------------
Maximum
Regulated parameter Maximum monthly avg.
daily \1\ \1\------------------------------------------------------------------------Ammonia (as N).............................. 8.0 4.0BOD5........................................ 26 16Fecal Coliform.............................. (\2\) (\3\)O&G; (as HEM)................................ 14 8.0TSS......................................... 30 20Total Nitrogen.............................. 147 103------------------------------------------------------------------------\1\ mg/L (ppm).\2\ Maximum of 400 MPN or CFU per 100 mL at any time.\3\ No maximum monthly average limitation.