Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 467  /  Sec. 467.63 Effluent limitations representing the degree of effluenteconomically achievable.

Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best available technology economically achievable. The discharge of wastewater pollutants from the core shall not exceed the volumes set forth below:

Subpart F

Core ------------------------------------------------------------------------

BAT effluent limitations

---------------------------

Pollutant or pollutant property Maximum for

Maximum for monthly

any 1 day average------------------------------------------------------------------------

mg/off-kg (lb/million off-

lbs) of aluminum drawn

with emulsions or soaps

---------------------------Chromium.................................... 0.205 0.084Cyanide..................................... 0.135 0.056Zinc........................................ 0.681 0.285Aluminum.................................... 3.00 1.49------------------------------------------------------------------------

Subpart F

Continuous Rod Casting Spent Lubricant ------------------------------------------------------------------------

BAT effluent limitations

--------------------------

Pollutant or pollutant property Maximum for

Maximum for monthly

any 1 day average------------------------------------------------------------------------

mg/off-kg (lb/million off-

lbs) of aluminum rod cast

--------------------------Chromium..................................... 0.0009 0.0004Cyanide...................................... 0.0006 0.0003Zinc......................................... 0.0029 0.0012Aluminum..................................... 0.013 0.0063------------------------------------------------------------------------

Subpart F

Continuous Rod Casting Contact Cooling Water ------------------------------------------------------------------------

BAT effluent limitations

---------------------------

Pollutant or pollutant property Maximum for

Maximum for monthly

any 1 day average------------------------------------------------------------------------

mg/off-kg (lb/million off-

lbs) of aluminum rod cast

---------------------------Chromium.................................... 0.086 0.035Cyanide..................................... 0.056 0.024Zinc........................................ 0.283 0.118Aluminum.................................... 1.25 0.62------------------------------------------------------------------------

Subpart F

Solution Heat Treatment Contact Cooling Water ------------------------------------------------------------------------

BAT effluent limitations

--------------------------

Pollutant or pollutant property Maximum for

Maximum for monthly

any 1 day average------------------------------------------------------------------------

mg/off-kg (lb/million off-

lbs) of aluminum quenched

--------------------------Chromium..................................... 0.897 0.37Cyanide...................................... 0.591 0.25Zinc......................................... 2.98 1.24Aluminum..................................... 13.10 6.52------------------------------------------------------------------------

Subpart F

Cleaning or Etching Bath ------------------------------------------------------------------------

BAT effluent limitations

---------------------------

Pollutant or pollutant property Maximum for

Maximum for monthly

any 1 day average------------------------------------------------------------------------

mg/off-kg (lb/million off-

lbs) of aluminum cleaned

or etched

---------------------------Chromium.................................... 0.079 0.032Cyanide..................................... 0.052 0.022Zinc........................................ 0.262 0.11Aluminum.................................... 1.15 0.57------------------------------------------------------------------------

Subpart F

Cleaning or Etching Rinse ------------------------------------------------------------------------

BAT effluent limitations

---------------------------

Pollutant or pollutant property Maximum for

Maximum for monthly

any 1 day average------------------------------------------------------------------------

mg/off-kg (lb/million off-

lbs) of aluminum cleaned

or etched

---------------------------Chromium.................................... 0.612 0.251Cyanide..................................... 0.404 0.167Zinc........................................ 2.03 0.849Aluminum.................................... 8.95 4.45------------------------------------------------------------------------

Subpart F

Cleaning or Etching Scrubber Liquor ------------------------------------------------------------------------

BAT effluent limitations

---------------------------

Pollutant or pollutant property Maximum for

Maximum for monthly

any 1 day average------------------------------------------------------------------------

mg/off-kg (lb/million off-

lbs) of aluminum cleaned

or etched

---------------------------Chromium.................................... 0.85 0.348Cyanide..................................... 0.561 0.232Zinc........................................ 2.82 1.18Aluminum.................................... 12.43 6.19------------------------------------------------------------------------ [48 FR 49149, Oct. 24, 1983; 49 FR 11633, 11635, and 11636, Mar. 27, 1984]