You must use the following test methods to determine compliance with the applicable emission limits:
(a) Method 1 in appendix A to part 60 of this chapter for the selection of the sampling port locations and number of sampling ports.
(b) Method 2 in appendix A to part 60 of this chapter for stack gas velocity and volumetric flow rate.
(c) Method 3 or 3A in appendix A to part 60 of this chapter for oxygen and carbon dioxide for diluent measurements needed to correct the concentration measurements to a standard basis.
(d) Method 4 in appendix A to part 60 of this chapter for moisture content of the stack gas.
(e) Method 5 in appendix A to part 60 of this chapter for the concentration of PM. Each PM test run must consist of a minimum run time of three hours and a minimum sample volume of 3.75 dscm (135 dscf).
(f) Method 10 in appendix A to part 60 of this chapter for the concentration of CO, using the continuous sampling option described in section 7.1.1 of the method. Each CO test run must consist of a minimum run time of one hour.
(g) Method 318 in appendix A to this part for the concentration of formaldehyde or CO.
(h) Method to determine the free-formaldehyde content of each resin lot in appendix A of this subpart.