CFR /  Title 40  /  Part 63  /  Sec. 63.1314 Storage vessel provisions.

(a) This section applies to each storage vessel that is assigned to an affected source, as determined by Sec. 63.1310(g). Except as provided in paragraphs (b) through (d) of this section, the owner or operator of an affected source shall comply with the requirements of Sec. Sec. 63.119 through 63.123 and 63.148 for those storage vessels, with the differences noted in paragraphs (a)(1) through (a)(17) of this section for the purposes of this subpart.

(1) When the term ``storage vessel'' is used in Sec. Sec. 63.119 through 63.123, the definition of this term in Sec. 63.1312 shall apply for the purposes of this subpart.

(2) When the term ``Group 1 storage vessel'' is used in Sec. Sec. 63.119 through 63.123, the definition of this term in Sec. 63.1312 shall apply for the purposes of this subpart.

(3) When the term ``Group 2 storage vessel'' is used in Sec. Sec. 63.119 through 63.123, the definition of this term in Sec. 63.1312 shall apply for the purposes of this subpart.

(4) When the emissions averaging provisions of Sec. 63.150 are referred to in Sec. Sec. 63.119 and 63.123, the emissions averaging provisions contained in Sec. 63.1332 shall apply for the purposes of this subpart.

(5) When December 31, 1992, is referred to in Sec. 63.119, March 29, 1995 shall apply instead, for the purposes of this subpart.

(6) When April 22, 1994, is referred to in Sec. 63.119, June 19, 2000 shall apply instead, for the purposes of this subpart.

(7) Each owner or operator of an affected source shall comply with this paragraph (a)(7) instead of Sec. 63.120(d)(1)(ii) for the purposes of this subpart. If the control device used to comply with Sec. 63.119(e) is also used to comply with any of the requirements found in Sec. 63.1315, Sec. 63.1316, Sec. 63.1322, or Sec. 63.1330, the performance test required in or accepted by the applicable requirements of Sec. Sec. 63.1315, 63.1316, 63.1322, and 63.1330 is acceptable for demonstrating compliance with Sec. 63.119(e) for the purposes of this subpart. The owner or operator is not required to prepare a design evaluation for the control device as described in Sec. 63.120(d)(1)(i), if the performance test meets the criteria specified in paragraphs (a)(7)(i) and (a)(7)(ii) of this section.

(i) The performance test demonstrates that the control device achieves greater than or equal to the required control efficiency specified in Sec. 63.119(e)(1) or Sec. 63.119(e)(2), as applicable; and

(ii) The performance test is submitted as part of the Notification of Compliance Status required by Sec. 63.1335(e)(5).

(8) When the term ``range'' is used in Sec. Sec. 63.120(d)(3), 63.120(d)(5), and 63.122(g)(2), the term ``level'' shall apply instead, for the purposes of this subpart.

(9) For purposes of this subpart, the monitoring plan required by Sec. 63.120(d)(2) shall specify for which control devices the owner or operator has selected to follow the procedures for continuous monitoring specified in Sec. 63.1334. For those control devices for which the owner or operator has selected to not follow the procedures for continuous monitoring specified in Sec. 63.1334, the monitoring plan shall include a description of the parameter or parameters to be monitored to ensure that the control device is being properly operated and maintained, an explanation of the criteria used for selection of that parameter (or parameters), and the frequency with which monitoring will be performed (e.g., when the liquid level in the storage vessel is being raised), as specified in Sec. 63.120(d)(2)(i).

(10) For purposes of this subpart, the monitoring plan required by Sec. 63.122(b) shall be included in the Notification of Compliance Status required by Sec. 63.1335(e)(5).

(11) When the Notification of Compliance Status requirements contained in Sec. 63.152(b) are referred to in Sec. Sec. 63.120, 63.122, and 63.123, the Notification of Compliance Status requirements contained in Sec. 63.1335(e)(5) shall apply for the purposes of this subpart.

(12) When the Periodic Report requirements contained in Sec. 63.152(c) are referred to in Sec. Sec. 63.120 and 63.122, the Periodic Report requirements contained in Sec. 63.1335(e)(6) shall apply for the purposes of this subpart.

(13) When other reports as required in Sec. 63.152(d) are referred to in Sec. 63.122, the reporting requirements contained in Sec. 63.1335(e)(7) shall apply for the purposes of this subpart.

(14) When the Initial Notification requirements contained in Sec. 63.151(b) are referred to in Sec. 63.122, the owner or operator of an affected source subject to this subpart need not comply for the purposes of this subpart.

(15) When the determination of equivalence criteria in Sec. 63.102(b) is referred to in Sec. 63.121(a), the provisions in Sec. 63.6(g) shall apply for the purposes of this subpart.

(16) When Sec. 63.119(a) requires compliance according to the schedule provisions in Sec. 63.100, owners and operators of affected sources shall instead comply with the requirements in Sec. Sec. 63.119(a)(1) through 63.119(a)(4) by the compliance date for storage vessels, which is specified in Sec. 63.1311.

(17) In Sec. 63.120(e)(1), instead of the reference to Sec. 63.11(b), the requirements of Sec. 63.1333(e) shall apply.

(b) Owners or operators of Group 1 storage vessels that are assigned to a new affected source producing SAN using a continuous process shall control emissions to the levels indicated in paragraphs (b)(1) and (b)(2) of this section.

(1) For storage vessels with capacities greater than or equal to 2,271 cubic meters (m\3\) containing a liquid mixture having a vapor pressure greater than or equal to 0.5 kilopascal (kPa) but less than 0.7 kPa, emissions shall be controlled by at least 90 percent relative to uncontrolled emissions.

(2) For storage vessels with capacities less than 151 m\3\ containing a liquid mixture having a vapor pressure greater than or equal to 10 kPa, emissions shall be controlled by at least 98 percent relative to uncontrolled emissions.

(3) For all other storage vessels designated as Group 1 storage vessels, emissions shall be controlled to the level designated in Sec. 63.119.

(c) Owners or operators of Group 1 storage vessels that are assigned to a new or existing affected source producing ASA/AMSAN shall control emissions by at least 98 percent relative to uncontrolled emissions.

(d) The provisions of this subpart do not apply to storage vessels containing ethylene glycol at existing or new affected sources and storage vessels containing styrene at existing affected sources.[61 FR 48229, Sept. 12, 1996, as amended at 64 FR 11547, Mar. 9, 1999; 65 FR 38107, June 19, 2000]