(a) Summary. (1) On and after the compliance date established by Sec. 63.1501, the owner or operator must operate all new and existing affected sources and control equipment according to the requirements in this section.
(1) On and after the compliance date established by Sec. 63.1501, the owner or operator must operate all new and existing affected sources and control equipment according to the requirements in this section.
(2) The owner or operator of an existing sweat furnace that meets the specifications of Sec. 63.1505(f)(1) must operate the sweat furnace and control equipment according to the requirements of this section on and after the compliance date of this standard.
(3) The owner or operator of a new sweat furnace that meets the specifications of Sec. 63.1505(f)(1) must operate the sweat furnace and control equipment according to the requirements of this section by March 23, 2000 or upon startup, whichever is later.
(4) Operating requirements are summarized in Table 2 to this subpart.
(b) Labeling. The owner or operator must provide and maintain easily visible labels posted at each group 1 furnace, group 2 furnace, in-line fluxer and scrap dryer/delacquering kiln/decoating kiln that identifies the applicable emission limits and means of compliance, including:
(1) The type of affected source or emission unit (e.g., scrap dryer/delacquering kiln/decoating kiln, group 1 furnace, group 2 furnace, in-line fluxer).
(2) The applicable operational standard(s) and control method(s) (work practice or control device). This includes, but is not limited to, the type of charge to be used for a furnace (e.g., clean scrap only, all scrap, etc.), flux materials and addition practices, and the applicable operating parameter ranges and requirements as incorporated in the OM&M; plan.
(3) The afterburner operating temperature and design residence time for a scrap dryer/delacquering kiln/decoating kiln.
(c) Capture/collection systems. For each affected source or emission unit equipped with an add-on air pollution control device, the owner or operator must:
(1) Design and install a system for the capture and collection of emissions to meet the engineering standards for minimum exhaust rates as published by the American Conference of Governmental Industrial Hygienists in chapters 3 and 5 of ``Industrial Ventilation: A Manual of Recommended Practice'' (incorporated by reference in Sec. 63.1502 of this subpart);
(2) Vent captured emissions through a closed system, except that dilution air may be added to emission streams for the purpose of controlling temperature at the inlet to a fabric filter; and
(3) Operate each capture/collection system according to the procedures and requirements in the OM&M; plan.
(d) Feed/charge weight. The owner or operator of each affected source or emission unit subject to an emission limit in kg/Mg (lb/ton) or [micro]g/Mg (gr/ton) of feed/charge must:
(1) Except as provided in paragraph (d)(3) of this section, install and operate a device that measures and records or otherwise determine the weight of feed/charge (or throughput) for each operating cycle or time period used in the performance test; and
(2) Operate each weight measurement system or other weight determination procedure in accordance with the OM&M; plan.
(3) The owner or operator may chose to measure and record aluminum production weight from an affected source or emission unit rather than feed/charge weight to an affected source or emission unit, provided that:
(i) The aluminum production weight, rather than feed/charge weight is measured and recorded for all emission units within a SAPU; and
(ii) All calculations to demonstrate compliance with the emission limits for SAPUs are based on aluminum production weight rather than feed/charge weight.
(e) Aluminum scrap shredder. The owner or operator of a scrap shredder with emissions controlled by a fabric filter must operate a bag leak detection system, or a continuous opacity monitor, or conduct visible emissions observations.
(1) If a bag leak detection system is used to meet the monitoring requirements in Sec. 63.1510, the owner or operator must:
(i) Initiate corrective action within 1-hour of a bag leak detection system alarm and complete the corrective action procedures in accordance with the OM&M; plan.
(ii) Operate each fabric filter system such that the bag leak detection system alarm does not sound more than 5 percent of the operating time during a 6-month block reporting period. In calculating this operating time fraction, if inspection of the fabric filter demonstrates that no corrective action is required, no alarm time is counted. If corrective action is required, each alarm shall be counted as a minimum of 1 hour. If the owner or operator takes longer than 1 hour to initiate corrective action, the alarm time shall be counted as the actual amount of time taken by the owner or operator to initiate corrective action.
(2) If a continuous opacity monitoring system is used to meet the monitoring requirements in Sec. 63.1510, the owner or operator must initiate corrective action within 1-hour of any 6-minute average reading of 5 percent or more opacity and complete the corrective action procedures in accordance with the OM&M; plan.
(3) If visible emission observations are used to meet the monitoring requirements in Sec. 63.1510, the owner or operator must initiate corrective action within 1-hour of any observation of visible emissions during a daily visible emissions test and complete the corrective action procedures in accordance with the OM&M; plan.
(f) Thermal chip dryer. The owner or operator of a thermal chip dryer with emissions controlled by an afterburner must:
(1) Maintain the 3-hour block average operating temperature of each afterburner at or above the average temperature established during the performance test.
(2) Operate each afterburner in accordance with the OM&M; plan.
(3) Operate each thermal chip dryer using only unpainted aluminum chips as the feedstock.
(g) Scrap dryer/delacquering kiln/decoating kiln. The owner or operator of a scrap dryer/delacquering kiln/decoating kiln with emissions controlled by an afterburner and a lime-injected fabric filter must:
(1) For each afterburner,
(i) Maintain the 3-hour block average operating temperature of each afterburner at or above the average temperature established during the performance test.
(ii) Operate each afterburner in accordance with the OM&M; plan.
(2) If a bag leak detection system is used to meet the fabric filter monitoring requirements in Sec. 63.1510,
(i) Initiate corrective action within 1-hour of a bag leak detection system alarm and complete any necessary corrective action procedures in accordance with the OM&M; plan.
(ii) Operate each fabric filter system such that the bag leak detection system alarm does not sound more than 5 percent of the operating time during a 6-month block reporting period. In calculating this operating time fraction, if inspection of the fabric filter demonstrates that no corrective action is required, no alarm time is counted. If corrective action is required, each alarm shall be counted as a minimum of 1 hour. If the owner or operator takes longer than 1 hour to initiate corrective action, the alarm time shall be counted as the actual amount of time taken by the owner or operator to initiate corrective action.
(3) If a continuous opacity monitoring system is used to meet the monitoring requirements in Sec. 63.1510, initiate corrective action within 1-hour of any 6-minute average reading of 5 percent or more opacity and complete the corrective action procedures in accordance with the OM&M; plan.
(4) Maintain the 3-hour block average inlet temperature for each fabric filter at or below the average temperature established during the performance test, plus 14 [deg]C (plus 25 [deg]F).
(5) For a continuous injection device, maintain free-flowing lime in the hopper to the feed device at all times and maintain the lime feeder setting at the same level established during the performance test.
(h) Sweat furnace. The owner or operator of a sweat furnace with emissions controlled by an afterburner must:
(1) Maintain the 3-hour block average operating temperature of each afterburner at or above:
(i) The average temperature established during the performance test; or
(ii) 1600 [deg]F if a performance test was not conducted, and the afterburner meets the specifications of Sec. 63.1505(f)(1).
(2) Operate each afterburner in accordance with the OM&M; plan.
(i) Dross-only furnace. The owner or operator of a dross-only furnace with emissions controlled by a fabric filter must:
(1) If a bag leak detection system is used to meet the monitoring requirements in Sec. 63.1510,
(i) Initiate corrective action within 1-hour of a bag leak detection system alarm and complete the corrective action procedures in accordance with the OM&M; plan.
(ii) Operate each fabric filter system such that the bag leak detection system alarm does not sound more than 5 percent of the operating time during a 6-month block reporting period. In calculating this operating time fraction, if inspection of the fabric filter demonstrates that no corrective action is required, no alarm time is counted. If corrective action is required, each alarm shall be counted as a minimum of 1 hour. If the owner or operator takes longer than 1 hour to initiate corrective action, the alarm time shall be counted as the actual amount of time taken by the owner or operator to initiate corrective action.
(2) If a continuous opacity monitoring system is used to meet the monitoring requirements in Sec. 63.1510, initiate corrective action within 1-hour of any 6-minute average reading of 5 percent or more opacity and complete the corrective action procedures in accordance with the OM&M; plan.
(3) Operate each furnace using dross and salt flux as the sole feedstock.
(j) Rotary dross cooler. The owner or operator of a rotary dross cooler with emissions controlled by a fabric filter must:
(1) If a bag leak detection system is used to meet the monitoring requirements in Sec. 63.1510,
(i) Initiate corrective action within 1-hour of a bag leak detection system alarm and complete the corrective action procedures in accordance with the OM&M; plan.
(ii) Operate each fabric filter system such that the bag leak detection system alarm does not sound more than 5 percent of the operating time during a 6-month block reporting period. In calculating this operating time fraction, if inspection of the fabric filter demonstrates that no corrective action is required, no alarm time is counted. If corrective action is required, each alarm shall be counted as a minimum of 1 hour. If the owner or operator takes longer than 1 hour to initiate corrective action, the alarm time shall be counted as the actual amount of time taken by the owner or operator to initiate corrective action.
(2) If a continuous opacity monitoring system is used to meet the monitoring requirements in Sec. 63.1510, initiate corrective action within 1 hour of any 6-minute average reading of 5 percent or more opacity and complete the corrective action procedures in accordance with the OM&M; plan.
(k) In-line fluxer. The owner or operator of an in-line fluxer with emissions controlled by a lime-injected fabric filter must:
(1) If a bag leak detection system is used to meet the monitoring requirements in Sec. 63.1510,
(i) Initiate corrective action within 1-hour of a bag leak detection system alarm and complete the corrective action procedures in accordance with the OM&M; plan.
(ii) Operate each fabric filter system such that the bag leak detection system alarm does not sound more than 5 percent of the operating time during a 6-month block reporting period. In calculating this operating time fraction, if inspection of the fabric filter demonstrates that no corrective action is required, no alarm time is counted. If corrective action is required, each alarm shall be counted as a minimum of 1 hour. If the owner or operator takes longer than 1 hour to initiate corrective action, the alarm time shall be counted as the actual amount of time taken by the owner or operator to initiate corrective action.
(2) If a continuous opacity monitoring system is used to meet the monitoring requirements in Sec. 63.1510, initiate corrective action within 1 hour of any 6-minute average reading of 5 percent or more opacity and complete the corrective action procedures in accordance with the OM&M; plan.
(3) For a continuous injection system, maintain free-flowing lime in the hopper to the feed device at all times and maintain the lime feeder setting at the same level established during the performance test.
(4) Maintain the total reactive chlorine flux injection rate for each operating cycle or time period used in the performance test at or below the average rate established during the performance test.
(l) In-line fluxer using no reactive flux material. The owner or operator of a new or existing in-line fluxer using no reactive flux materials must operate each in-line fluxer using no reactive flux materials.
(m) Group 1 furnace with add-on air pollution control devices. The owner or operator of a group 1 furnace with emissions controlled by a lime-injected fabric filter must:
(1) If a bag leak detection system is used to meet the monitoring requirements in Sec. 63.1510, the owner or operator must:
(i) Initiate corrective action within 1 hour of a bag leak detection system alarm.
(ii) Complete the corrective action procedures in accordance with the OM&M; plan.
(iii) Operate each fabric filter system such that the bag leak detection system alarm does not sound more than 5 percent of the operating time during a 6-month block reporting period. In calculating this operating time fraction, if inspection of the fabric filter demonstrates that no corrective action is required, no alarm time is counted. If corrective action is required, each alarm shall be counted as a minimum of 1 hour. If the owner or operator takes longer than 1 hour to initiate corrective action, the alarm time shall be counted as the actual amount of time taken by the owner or operator to initiate corrective action.
(2) If a continuous opacity monitoring system is used to meet the monitoring requirements in Sec. 63.1510, the owner or operator must:
(i) Initiate corrective action within 1 hour of any 6-minute average reading of 5 percent or more opacity; and
(ii) Complete the corrective action procedures in accordance with the OM&M; plan.
(3) Maintain the 3-hour block average inlet temperature for each fabric filter at or below the average temperature established during the performance test, plus 14 [deg]C (plus 25 [deg]F).
(4) For a continuous lime injection system, maintain free-flowing lime in the hopper to the feed device at all times and maintain the lime feeder setting at the same level established during the performance test.
(5) Maintain the total reactive chlorine flux injection rate for each operating cycle or time period used in the performance test at or below the average rate established during the performance test.
(6) Operate each sidewell furnace such that:
(i) The level of molten metal remains above the top of the passage between the sidewell and hearth during reactive flux injection, unless emissions from both the sidewell and the hearth are included in demonstrating compliance with all applicable emission limits.
(ii) Reactive flux is added only in the sidewell, unless emissions from both the sidewell and the hearth are included in demonstrating compliance with all applicable emission limits.
(n) Group 1 furnace without add-on air pollution control devices. The owner or operator of a group 1 furnace (including a group 1 furnace that is part of a secondary aluminum processing unit) without add-on air pollution control devices must:
(1) Maintain the total reactive chlorine flux injection rate for each operating cycle or time period used in the performance test at or below the average rate established during the performance test.
(2) Operate each furnace in accordance with the work practice/pollution prevention measures documented in the OM&M; plan and within the parameter values or ranges established in the OM&M; plan.
(3) Operate each group 1 melting/holding furnace subject to the emission standards in Sec. 63.1505(i)(2) using only clean charge as the feedstock.
(o) Group 2 furnace. The owner or operator of a new or existing group 2 furnace must:
(1) Operate each furnace using only clean charge as the feedstock.
(2) Operate each furnace using no reactive flux.
(p) Corrective action. When a process parameter or add-on air pollution control device operating parameter deviates from the value or range established during the performance test and incorporated in the OM&M; plan, the owner or operator must initiate corrective action. Corrective action must restore operation of the affected source or emission unit (including the process or control device) to its normal or usual mode of operation as expeditiously as practicable in accordance with good air pollution control practices for minimizing emissions. Corrective actions taken must include follow-up actions necessary to return the process or control device parameter level(s) to the value or range of values established during the performance test and steps to prevent the likely recurrence of the cause of a deviation. [65 FR 15710, Mar. 23, 2000, as amended at 67 FR 59792, Sept. 24, 2002; 67 FR 79816, Dec. 30, 2002; 69 FR 53984, Sept. 3, 2004] Sec. Sec. 63.1507-63.1509 [Reserved]
Monitoring and Compliance Requirements