Code of Federal Regulations (alpha)

CFR /  Title 40  /  Part 63  /  Sec. 63.3420 What authorities may be delegated to the States?

(a) In delegating implementation and enforcement authority to a State under 40 CFR part 63, subpart E, the authorities contained in paragraph (b) of this section must be retained by the Administrator and not transferred to a State.

(b) Authority which will not be delegated to States: Sec. 63.3360(c), approval of alternate test method for organic HAP content determination; Sec. 63.3360(d), approval of alternate test method for volatile matter determination.

Sec. Table 1 to Subpart JJJJ of Part 63--Operating Limits if Using Add-

On Control Devices and Capture System

If you are required to comply with operating limits by Sec. 63.3321, you must comply with the applicable operating limits in the following table: ------------------------------------------------------------------------

And you must

You must meet the demonstrate

For the following device: following operating continuous

limit: compliance with

operating limits by:------------------------------------------------------------------------1. Thermal oxidizer......... a. The average i. Collecting the

combustion combustion

temperature in any temperature data

3-hour period must according to Sec.

not fall below the 63.3350(e)(9);

combustion ii. Reducing the

temperature limit data to 3-hour

established block averages; and

according to Sec. iii. Maintain the 3-

63.3360(e)(3)(i). hour average

combustion

temperature at or

above the

temperature limit.2. Catalytic oxidizer....... a. The average i. Collecting the

temperature at the catalyst bed inlet

inlet to the temperature data

catalyst bed in any according to Sec.

3-hour period must 63.3350(e)(9);

not fall below the ii. Reducing the

combustion data to 3-hour

temperature limit block averages; and

established iii. Maintain the 3-

according to Sec. hour average

63.3360(e)(3)(ii). catalyst bed inlet

temperature at or

above the

temperature limit.

b. The temperature i. Collecting the

rise across the catalyst bed inlet

catalyst bed must and outlet

not fall below the temperature data

limit established according to Sec.

according to Sec. 63.3350(e)(9);

63.3360(e)(3)(ii). ii. Reducing the

data to 3-hour

block averages; and

iii. Maintain the 3-

hour average

temperature rise

across the catalyst

bed at or above the

limit.3. Emission capture system.. Submit monitoring Conduct monitoring

plan to the according to the

Administrator that plan (Sec.

identifies 63.3350(f)(3)).

operating

parameters to be

monitored according

to Sec.

63.3350(f).------------------------------------------------------------------------ Sec. Table 2 to Subpart JJJJ of Part 63--Applicability of 40 CFR Part 63

General Provisions to Subpart JJJJ

You must comply with the applicable General Provisions requirements according to the following table: ------------------------------------------------------------------------

Applicable toGeneral provisions reference subpart JJJJ Explanation------------------------------------------------------------------------Sec. 63.1(a)(1)-(4)....... Yes.Sec. 63.1(a)(5)........... No.................. Reserved.Sec. 63.1(a)(6)-(8)....... Yes.Sec. 63.1(a)(9)........... No.................. Reserved.Sec. 63.1(a)(10)-(14)..... Yes.Sec. 63.1(b)(1)........... No.................. Subpart JJJJ

specifies

applicability.Sec. 63.1(b)(2)-(3)....... Yes.Sec. 63.1(c)(1)........... Yes.Sec. 63.1(c)(2)........... No.................. Area sources are not

subject to emission

standards of

subpart JJJJ.

Sec. 63.1(c)(3)........... No.................. Reserved.Sec. 63.1(c)(4)........... Yes.Sec. 63.1(c)(5)........... Yes.Sec. 63.1(d).............. No.................. Reserved.Sec. 63.1(e).............. Yes.Sec. 63.1(e)(4)........... No.Sec. 63.2................. Yes................. Additional

definitions in

subpart JJJJ.Sec. 63.3(a)-(c).......... Yes.Sec. 63.4(a)(1)-(3)....... Yes.Sec. 63.4(a)(4)........... No.................. Reserved.Sec. 63.4(a)(5)........... Yes.Sec. 63.4(b)-(c).......... Yes.Sec. 63.5(a)(1)-(2)....... Yes.Sec. 63.5(b)(1)........... Yes.Sec. 63.5(b)(2)........... No.................. Reserved.Sec. 63.5(b)(3)-(6)....... Yes.Sec. 63.5(c).............. No.................. Reserved.Sec. 63.5(d).............. Yes.Sec. 63.5(e).............. Yes.Sec. 63.5(f).............. Yes.Sec. 63.6(a).............. Yes................. Applies only when

capture and control

system is used to

comply with the

standard.Sec. 63.6(b)(1)-(5)....... No..................Sec. 63.6(b)(6)........... No.................. Reserved.Sec. 63.6(b)(7)........... Yes.Sec. 63.6(c)(1)-(2)....... Yes.Sec. 63.6(c)(3)-(4)....... No.................. Reserved.Sec. 63.6(c)(5)........... Yes.Sec. 63.6(d).............. No.................. Reserved.Sec. 63.6(e).............. Yes................. Provisions

pertaining to SSMP,

and CMS do not

apply unless an add-

on control system

is used to comply

with the emission

limitations.Sec. 63.6(f).............. Yes.Sec. 63.6(g).............. Yes.Sec. 63.6(h).............. No.................. Subpart JJJJ does

not require

continuous opacity

monitoring systems

(COMS).Sec. 63.6(i)(1)-(14)...... Yes.Sec. 63.6(i)(15).......... No.................. Reserved.Sec. 63.6(i)(16).......... Yes.Sec. 63.6(j).............. Yes.Sec. 63.7................. Yes.Sec. 63.8(a)(1)-(2)....... Yes.Sec. 63.8(a)(3)........... No.................. Reserved.Sec. 63.8(a)(4)........... No.Sec. 63.8(b).............. Yes.Sec. 63.8(c)(1)-(3)....... Yes................. Sec. 63.8(c)(1)(i)

& (ii) only apply

if you use capture

and control systems

and are required to

have a start-up,

shutdown, and

malfunction plan.Sec. 63.8(c)(4)........... Yes.Sec. 63.8(c)(5)........... No.................. Subpart JJJJ does

not require COMS.Sec. 63.8(c)(6)-(c)(8).... Yes................. Provisions for COMS

are not applicable.Sec. 63.8(d)-(f).......... Yes................. Sec. 63.8(f)(6)

only applies if you

use CEMS.Sec. 63.8(g).............. Yes................. Only applies if you

use CEMS.Sec. 63.9(a).............. Yes.Sec. 63.9(b)(1)........... Yes.Sec. 63.9(b)(2)........... Yes................. Except Sec.

63.3400(b)(1)

requires submittal

of initial

notification for

existing affected

sources no later

than 1 year before

compliance date.Sec. 63.9(b)(3)-(5)....... Yes.Sec. 63.9(c)-(e).......... Yes.Sec. 63.9(f).............. No.................. Subpart JJJJ does

not require opacity

and visible

emissions

observations.Sec. 63.9(g).............. Yes................. Provisions for COMS

are not applicable.Sec. 63.9(h)(1)-(3)....... Yes.Sec. 63.9(h)(4)........... No.................. Reserved.Sec. 63.9(h)(5)-(6)....... Yes.Sec. 63.9(i).............. Yes.Sec. 63.9(j).............. Yes.

Sec. 63.10(a)............. Yes.Sec. 63.10(b)(1)-(3)...... Yes................. Sec.

63.10(b)(2)(i)

through (v) only

apply if you use a

capture and control

system.Sec. 63.10(c)(1).......... Yes.Sec. 63.10(c)(2)-(4)...... No.................. Reserved.Sec. 63.10(c)(5)-(8)...... Yes.Sec. 63.10(c)(9).......... No.................. Reserved.Sec. 63.10(c)(10)-(15).... Yes.Sec. 63.10(d)(1)-(2)...... Yes.Sec. 63.10(d)(3).......... No.................. Subpart JJJJ does

not require opacity

and visible

emissions

observations.Sec. 63.10(d)(4)-(5)...... Yes.Sec. 63.10(e)(1)-(2)...... Yes................. Provisions for COMS

are not applicable.Sec. 63.10(e)(3)-(4)...... No.Sec. 63.10(f)............. Yes.Sec. 63.11................ No.Sec. 63.12................ Yes.Sec. 63.13................ Yes.Sec. 63.14................ Yes................. Subpart JJJJ

includes provisions

for alternative

ASME test methods

that are

incorporated by

reference.Sec. 63.15................ Yes.------------------------------------------------------------------------

Subpart KKKK_National Emission Standards for Hazardous Air Pollutants:

Surface Coating of Metal Cans

Source: 68 FR 64446, Nov. 13, 2003, unless otherwise noted.

What This Subpart Covers