(a) You must conduct each performance test required by Sec. 63.4160 according to the requirements in Sec. 63.7(e)(1) and under the conditions in this section unless you obtain a waiver of the performance test according to the provisions in Sec. 63.7(h).
(1) Representative coating operation operating conditions. You must conduct the performance test under representative operating conditions for the coating operation. Operations during periods of startup, shutdown, or malfunction and periods of nonoperation do not constitute representative conditions. You must record the process information that is necessary to document operating conditions during the test and explain why the conditions represent normal operation.
(2) Representative emission capture system and add-on control device operating conditions. You must conduct the performance test when the emission capture system and add-on control device are operating at a representative flow rate, and the add-on control device is operating at a representative inlet concentration. You must record information that is necessary to document emission capture system and add-on control device operating conditions during the test and explain why the conditions represent normal operation.
(b) You must conduct each performance test of an emission capture system according to the requirements in Sec. 63.4165 and of an add-on control device according to the requirements in Sec. 63.4166.
(c) The performance test to determine add-on control device organic HAP destruction or removal efficiency must consist of three runs as specified in Sec. 63.7(e)(3) and each run must last at least 1 hour.