(a) The owner or operator of any affected BLR source shall keep records of daily average values of equipment operating parameters specified to be monitored under Sec. 63.526(a) or specified by the Administrator. Records shall be kept in accordance with the requirements of applicable paragraphs of Sec. 63.10 of subpart A of this part, as specified in the General Provisions applicability table of this subpart. The owner or operator shall keep records up-to-date and readily accessible.
(1) A daily (24-hour) average shall be calculated as the average of all values for a monitored parameter recorded during the operating day. The average shall cover a 24-hour period if operation is continuous, or the number of hours of operation per operating day if operation is not continuous.
(2) The operating day shall be the period defined in the operating permit or the Notification of Compliance Status in Sec. 63.9(h) of subpart A of this part. It may be from midnight to midnight or another continuous 24-hour period.
(3) In the event of an excursion, the owner or operator must keep records of each 15-minute reading during the period in which the excursion occurred.
(b) The owner or operator of any affected WSR source that elects to comply with the emission limit for process vents, storage tanks, and wastewater systems shall keep records of values of equipment operating parameters specified to be monitored under Sec. 63.526(b) or specified by the Administrator. The records that shall be kept are the average values of operating parameters, determined for the duration of each unit operation. Records shall be kept in accordance with the requirements of applicable paragraphs of Sec. 63.10 of subpart A of this part, as specified in the General Provisions applicability table in this subpart. The owner or operator shall keep records up-to-date and readily accessible. In the event of an excursion, the owner or operator must keep records of each 15-minute reading for the entire unit operation in which the excursion occurred.
(c) The owner or operator of any affected BLR source, as well the owner or operator of any affected WSR source that chooses to comply with the emission limit for process vents, storage tanks, and wastewater systems, who demonstrates that certain process vents are below the de minimis cutoff for continuous monitoring specified in Sec. 63.526(a)(1)(i), shall maintain up-to-date, readily accessible records of the following information to document that a HAP emission rate of less than one pound per year is maintained:
(1) The information used to determine de minimis status for each de minimis process vent, as specified in Sec. 63.526(a)(1)(i);
(2) Any process changes as defined in Sec. 63.115(e) of subpart G of this part that increase the HAP emission rate;
(3) Any recalculation or measurement of the HAP emission rate pursuant to Sec. 63.115(e) of subpart G of this part; and
(4) Whether or not the HAP emission rate increases to one pound per year or greater as a result of the process change.
(d) The owner or operator of any affected BLR source, as well as the owner or operator of any affected WSR source who elects to implement the leak detection and repair program specified in subpart H of this part, shall implement the recordkeeping requirements outlined therein. All records shall be retained for a period of 5 years, in accordance with the requirements of 40 CFR 63.10(b)(1).
(e) Any excursion from the required monitoring parameter, unless otherwise excused, shall be considered a violation of the emission standard.