(a) Except as provided in paragraph (b) of this section, each owner or operator of a Group 1 wastewater stream shall comply with the requirements of Sec. Sec. 61.340 through 61.355 of 40 CFR part 61, subpart FF for each process wastewater stream that meets the definition in Sec. 63.641.
(b) As used in this section, all terms not defined in Sec. 63.641 shall have the meaning given them in the Clean Air Act or in 40 CFR part 61, subpart FF, Sec. 61.341.
(c) Each owner or operator required under subpart FF of 40 CFR part 61 to perform periodic measurement of benzene concentration in wastewater, or to monitor process or control device operating parameters shall operate in a manner consistent with the minimum or maximum (as appropriate) permitted concentration or operating parameter values. Operation of the process, treatment unit, or control device resulting in a measured concentration or operating parameter value outside the permitted limits shall constitute a violation of the emission standards. Failure to perform required leak monitoring for closed vent systems and control devices or failure to repair leaks within the time period specified in subpart FF of 40 CFR part 61 shall constitute a violation of the standard.