(a) By-product hydrogen streams and end box ventilation system vents. You must determine the total grams of mercury per Megagram of chlorine production (g Hg/Mg Cl2) of chlorine produced from all by-product hydrogen streams and all end box ventilation system vents, if applicable, at a mercury cell chlor-alkali production facility, and you must follow the procedures in paragraphs (a)(1) through (6) of this section.
(1) Determine the mercury emission rate for each test run in grams per day for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, from Method 101, 101A, or 102 (40 CFR part 61, appendix A).
(2) Calculate the average measured electric current through the operating mercury cells during each test run for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, using Equation 1 of this section as follows:[GRAPHIC] [TIFF OMITTED] TR19DE03.000 Where: CLavg, run = Average measured cell line current load during
the test run, amperes;CLi, run = Individual cell line current load measurement
(i.e., 15 minute reading) during the test run, amperes; andn = Number of cell line current load measurements taken over the
duration of the test run.
(3) Calculate the amount of chlorine produced during each test run for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, using Equation 2 of this section as follows: [GRAPHIC] [TIFF OMITTED] TR19DE03.001 Where: PCl2,run = Amount of chlorine produced during the
test run, megagrams chlorine (Mg Cl2);1.3 x 10 -6 = Theoretical chlorine production rate factor, Mg
Cl2 per hour per ampere per cell;CLavg,run = Average measured cell line current load during
test run, amperes, calculated using Equation 1 of this
section;ncell,run = Number of cells on-line during the test run; andtrun = Duration of test run, hours.
(4) Calculate the mercury emission rate in grams of mercury per megagram of chlorine produced for each test run for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, using Equation 3 of this section as follows:[GRAPHIC] [TIFF OMITTED] TR19DE03.002 Where: EHg,run = Mercury emission rate for the test run, g Hg/Mg
Cl2;Rrun = Measured mercury emission rate for the test run from
paragraph (a)(1) of this section, grams Hg per day;trun = Duration of test run, hours;24 = Conversion factor, hours per day; andPCl2,run = Amount of chlorine produced during the
test run, calculated using Equation 2 of this section, Mg
Cl2.
(5) Calculate the average mercury emission rate for each by-product hydrogen stream and for each end box ventilation system vent, if applicable, using Equation 4 of this section as follows:[GRAPHIC] [TIFF OMITTED] TR19DE03.003 Where: EHg,avg = Average mercury emission rate for the by-product
hydrogen stream or the end box ventilation system vent, if
applicable, g Hg/Mg Cl2;EHg,run = Mercury emission rate for each test run for the by-
product hydrogen stream or the end box ventilation system
vent, if applicable, g Hg/Mg Cl2, calculated using
Equation 3 of this section; andn = Number of test runs conducted for the by-product hydrogen stream or
the end box ventilation system vent, if applicable.
(6) Calculate the total mercury emission rate from all by-product hydrogen streams and all end box ventilation system vents, if applicable, at the mercury cell chlor-alkali production facility using Equation 5 of this section as follows:[GRAPHIC] [TIFF OMITTED] TR19DE03.004 Where: EHg,H2EB = Total mercury emission rate from all
by-product hydrogen streams and all end box ventilation system
vents, if applicable, at the affected source, g Hg/Mg
Cl2;EHg,avg = Average mercury emission rate for each by-product
hydrogen stream and each end box ventilation system vent, if
applicable, g Hg/Mg Cl2, determined using Equation
4 of this section; andn = Total number of by-product hydrogen streams and end box ventilation
system vents at the affected source.
(b) Mercury thermal recovery vents. You must determine the milligrams of mercury per dscm exhaust discharged from mercury thermal recovery unit vents, using the procedures in paragraphs (b)(1) and (2) of this section.
(1) Calculate the concentration of mercury in milligrams of mercury per dscm of exhaust for each test run for each mercury thermal recovery unit vent using Equation 6 of this section as follows:[GRAPHIC] [TIFF OMITTED] TR19DE03.005 Where: CHg,run = Mercury concentration for the test run, milligrams
of mercury per dry standard cubic meter of exhaust;mHg = Mass of mercury in test run sample, from Method 101,
101A, or 102, micrograms; 10-3 = Conversion factor, milligrams per microgram; andVm(std) = Dry gas sample volume at standard conditions, from
Method 101, 101A, or 102, dry standard cubic meters.
(2) Calculate the average concentration of mercury in each mercury thermal recovery unit vent exhaust using Equation 7 of this section as follows:[GRAPHIC] [TIFF OMITTED] TR19DE03.006 Where: CHg,avg = Average mercury concentration for the mercury
thermal recovery unit vent, milligrams of mercury per dry
standard cubic meter exhaust;CHg,run = Mercury concentration for each test run, milligrams
of mercury per dry standard cubic meter of exhaust, calculated
using Equation 6 of this section; andn = Number of test runs conducted for the mercury thermal recovery unit
vent.