Code of Federal Regulations (alpha)

CFR /  Title 42  /  Part 84  /  Sec. 84.1158 Dust, fume, and mist tests; respirators with filters;

(a) Three respirators with cartridges containing, or having attached to them, filters for protection against dusts, fumes, and mists, except the mists of paints, lacquers, and enamels, will be tested in accordance with the provisions of Sec. 84.1157(f).

(b) In addition to the test requirements set forth in paragraph (a) of this section, three such respirators will be tested, as appropriate, in accordance with the provisions of Sec. Sec. 84.1141 through 84.1152; however, the maximum allowable resistance of complete dust, fume, and mist, and gas, vapor, or gas and vapor chemical cartridge respirators shall not exceed the maximum allowable limits set forth in Sec. 84.1157(a)(2).

Sec. Tables to Subpart KK of Part 84

Table 12--Facepiece Test Requirements

[42 CFR Part 84, Subpart KK]------------------------------------------------------------------------

Pressure Isoamyl acetate test

Respirator types tightness ---------------------------

test \1\ 84.1141 84.1142------------------------------------------------------------------------Dusts: Air Contamination Level X

not less than 0.05 mg/M\3\ or

2 mppcf......................Fumes: Air Contamination Level X X

not less than 0.05 mg/M\3\...Mists: Air Contamination Level X

not less than 0.05 mg/M\3\ or

2 mppcf......................Dusts, Fumes, and Mists: Air X ............ X

Contamination Level less than

0.05 mg/M\3\ or 2 mppcf, and

radionuclides................Radon daughters............... X XAsbestos-containing dusts and X

mists........................------------------------------------------------------------------------\1\ Test is required only where applicable.

Table 13--Air-Purifying and Powered Air-Purifying Respirator Filter Tests Required for Approval

[42 CFR Part 84, Subpart KK]----------------------------------------------------------------------------------------------------------------

Silica dust tests

Respirator types ------------------------------------------ Lead fume Silica mist DOP test

84.1144 84.1145 84.1152 test 84.1146 test 84.1147 84.1151----------------------------------------------------------------------------------------------------------------Dusts: Air Contamination X

Level not less than 0.05 mg/

M\3\ or 2 mppcf............Fumes: Air Contamination ............ ............ ............ X

Level not less than 0.05 mg/

M\3\.......................Mists: Air Contamination ............ ............ ............ ............ X

Level not less than 0.05 mg/

M\3\ or 2 mppcf............Dusts, Fumes, and Mists: Air ............ ............ X ............ ............ X

Contamination Level less

than 0.05 mg/M\3\ or 2

mppcf, and radionuclides...Radon daughters............. \1\ X ............ ............ ............ \2\ XAsbestos-containing dusts \2\ X ............ ............ ............ \3\ X

and mists..................Single use dust and mist ............ \3\ X ............ ............ \3\ X

respirators................----------------------------------------------------------------------------------------------------------------\1\ For resistance only.\2\ For penetration only.\3\ Test required only where applicable.

Table 14--Carbon Tetrachloride Bench Tests and Requirements for Canisters and Cartridges

[42 CFR part 84, Subpart KK]----------------------------------------------------------------------------------------------------------------

Test Minimum

Type of pesticide respirator concentration Flow rate Number of life

p.p.m. CCl4 l.p.m. tests minutes \1\----------------------------------------------------------------------------------------------------------------Chest-mounted or back-mounted gas mask (as received)...... 20,000 64 3 12Chest-mounted or back-mounted gas mask (equilibrated)..... 20,000 32 4 12Chin-style gas mask (as received)......................... 5,000 64 3 12Chin-style gas mask (equilibrated)........................ 5,000 32 4 12Chemical Cartridge respirator (as received)............... 1,000 64 3 50Chemical cartridge respirator (equilibrated).............. 1,000 32 4 50Powered air-purifying respirator (tight-fitting facepiece, 1,000 \2\ 115 3 50

as received).............................................Powered air-purifying respirator (tight-fitting facepiece, 1,000 \2\ 115 4 25

equilibrated)............................................Powered air-purifying respirator (loose-fitting hood or 1,000 \3\ 170 3 50

helmet, as received).....................................Powered air-purifying respirator (loose-fitting hood or 1,000 \3\ 170 4 25

helmet, equilibrated)....................................----------------------------------------------------------------------------------------------------------------\1\ Minimum life will be determined at 5 p.p.m. leakage.\2\ The flow rate shall be the effective flow rate of the device, but shall be not less than 115 l.p.m.\3\ The flow rate shall be the effective flow rate of the device, but shall be not less than 170 l.p.m. Sec. Appendix A to Part 84--Annual (Fixed) Respirator Certification Fees

Respirator Certification Fee Schedule A--Annual (Fixed) Fees

[Implemented on May 26, 2015]----------------------------------------------------------------------------------------------------------------

Fee type Legal citation Amount Due date----------------------------------------------------------------------------------------------------------------Maintenance of Product Performance 42 CFR 84.20(b)(5)... Annual Upon

(product audit). fee: $761 per each billing from NIOSH.\1\

approval holder.

October.

Variable fee: As billed

by NIOSH based on the

respirators chosen to be

tested each year.Records Maintenance............... 42 CFR 84.20(b)(1)... $50 for all listed \2\ Upon

approvals on file with billing from NIOSH.\1\

NIOSH on July 1st of each

year. October (beginning in

2015).Quality Assurance Maintenance 42 CFR 84.20(b)(4)... Annual Upon

(site audit). fee: $3,000 per every billing from NIOSH.\1\

manufacturing site

registered with NIOSH. October (beginning in

2015).

Variable fee: \3\.

[squarf] 1 day domestic

audit--$2,500 per site.

[squarf] 2 day domestic

audit--$5,000 per site.

[squarf] 1 day

international audit--

$7,500 per site.

[squarf] 2 day

international audit--

$10,000 per site.

Maintenance of Testing and 42 CFR 84.20(b)(2)... $34 per every listed \2\ Upon

Approval Facilities. approval on file with billing from NIOSH.\1\

NIOSH on July 1st of each

applicable year. October (beginning in

2015).Maintenance of Test Equipment..... 42 CFR 84.20(b)(2)... $36 per every active \4\ Upon

approval on file with billing from NIOSH.\1\

NIOSH on July 1st of each

applicable year. October (beginning in

2015).----------------------------------------------------------------------------------------------------------------\1\ For the first year that annual fees are in effect, NIOSH will provide manufacturers with a pre-invoice/

advanced billing/invoice preview no later than July 1, 2015. The actual invoice will be sent in September

2015.\2\ ``Listed'' approvals include all active and obsolete approvals. The Certified Equipment List (CEL) reflects

the current listed approvals maintained by NIOSH. See http://www.cdc.gov/niosh/npptl/topics/respirators/CEL/

default.html.\3\ Applies to design as well as manufacturing sites.\4\ Does not include obsolete approvals. [80 FR 3908, Jan. 26, 2015]

Sec. Appendix B to Part 84--Application-Based Respirator Certification

Fees

Respirator Certification Fee Schedule B--Application-Based Fees

[Implemented on May 26, 2015]----------------------------------------------------------------------------------------------------------------

Fee type Legal citation Amount Due date----------------------------------------------------------------------------------------------------------------Application....................... 42 CFR 84.20(b)(1)... $200 per application Upon receipt of any

submitted. application request.Approval.......................... 42 CFR 84.20(b)(1)... $100 per each certificate Upon completion of the

of approval issued. application and granting

of an approval number.Approval Modification............. 42 CFR 84.20(b)(1)... $50 per each certificate Upon completion of the

of approval modified. application and issuing

a modified approval.Site Qualification................ 42 CFR 84.20(b)(3)... Upon agreement on the

Existing approval holder, date of the site

paper review: $400 per qualification

each request to inspect examination.

new production facility.

Non-

approval holders:.

[squarf] Domestic site

visit--$2,500.

[squarf] International

site visit--$7,500.---------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------

Standard Test Procedure Fee ($)------------------------------------------------------------------------

Testing Fees------------------------------------------------------------------------Descriptor:.................................... For testing

respirators.------------------------------------------------------------------------Amount:........................................ See below.------------------------------------------------------------------------Basis:......................................... Per each test.------------------------------------------------------------------------Due date:...................................... Upon initiation of

testing.------------------------------------------------------------------------

Air-Purifying Respirators------------------------------------------------------------------------TEB-APR-STP-0001 Determination of particulate 150

filter penetration (PAPR).RCT-APR-STP-0003--Determination of exhalation 150

resistance.TEB-APR-STP-0004--Determination of exhalation 300

valve leakage.TEB-APR-STP-0005--Determination of qualitative 1,800

isoamyl acetate (IAA) facepiece fit test.TEB-APR-STP-0005A--Determination of qualitative 1,800

isoamyl acetate (IAA) facepiece fit test.TEB-APR-STP-0006--Determination of qualitative 1,800

isoamyl acetate (IAA) facepiece fit test.TEB-APR-STP-0007--Determination of inhalation 150

resistance.RCT-APR-STP-0012--Determination of air flow for 150

powered air-purifying respirators.RCT-APR-STP-0014--Determination of leakage of 300

drinking tube and accessories for respirator

facepieces.RCT-APR-STP-0025--Determination of silica dust 1,200

loading test for powered air-purifying

respirator filters.RCT-APR-STP-0030--Determination of noise level 450

test, powered air-purifying respirator with

hoods or helmets.TEB-APR-STP-0033A--Determination of ammonia 750

service-life test, air-purifying respirators

with cartridges.TEB-APR-STP-0033B--Determination of ammonia 750

service-life test, air-purifying respirators

with canisters.TEB-APR-STP-0033C--Determination of ammonia 750

service-life test, powered air-purifying

respirators with cartridges.

TEB-APR-STP-0033D--Determination of ammonia 750

service-life test, tight-fitting powered air-

purifying respirators with gas mask

canister(s).RCT-APR-STP-0034--Carbon monoxide service life. 750RCT-APR-STP-0035--Determination of chlorine 750

service life.RCT-APR-STP-0036--Determination of chlorine 750

dioxide service life.RCT-APR-STP-0037--Determination of a- 2,400

chloroacetophenone (CN) service life.RCT-APR-STP-0038--Determination of ethylene 450

oxide service life.TEB-APR-STP-0039A--Determination of 750

formaldehyde service-life test, air-purifying

respirators with cartridges.TEB-APR-STP-0039B--Determination of 750

formaldehyde service-life test, air-purifying

respirators with canisters.TEB-APR-STP-0039C--Determination of 750

formaldehyde service-life test, powered air-

purifying respirators with cartridges.RCT-APR-STP-0040--Determination of hydrogen 500

chloride service life.RCT-APR-STP-0041--Determination of hydrogen 1,800

cyanide service life.RCT-APR-STP-0042--Determination of hydrogen 750

fluoride service life.TEB-APR-STP-0043A--Determination of hydrogen 750

sulfide service-life test, air-purifying

respirators with cartridges.TEB-APR-STP-0043B--Determination of hydrogen 750

sulfide service-life test, air-purifying

respirators with canisters.TEB-APR-STP-0043C--Determination of hydrogen 750

sulfide service-life test, powered air-

purifying respirators with cartridges.RCT-APR-STP-0044--Determination of mercury 2,400

vapor service life.TEB-APR-STP-0045A--Determination of methylamine 450

service-life test, air-purifying respirators

with cartridges.TEB-APR-STP-0045B--Determination of methylamine 450

service-life test, air-purifying respirators

with canisters.TEB-APR-STP-0045C--Determination of methylamine 450

service-life test, powered air-purifying

respirators with cartridges.TEB-APR-STP-0045D--Determination of methylamine 450

service-life test, tight-fitting powered air-

purifying respirators with gas mask

canister(s).TEB-APR-STP-0046A--Determination of organic 450

vapor (carbon tetrachloride) service-life

test, air-purifying respirators with

cartridges.TEB-APR-STP-0046B--Determination of organic 450

vapor (carbon tetrachloride) service-life

test, air-purifying respirators with

cartridges.TEB-APR-STP-0046C--Determination of organic 450

vapor (carbon tetrachloride) service-life

test, powered air-purifying respirators with

cartridges.TEB-APR-STP-0046D--Determination of organic 450

vapor (carbon tetrachloride) service-life

test, tight-fitting powered air-purifying

respirators with gas mask canister(s).RCT-APR-STP-0047--Determination of phosphine 750

service life.TEB-APR-STP-0048A--Determination of sulfur 450

dioxide service-life test, air-purifying

respirators with cartridges.TEB-APR-STP-0048B--Determination of sulfur 450

dioxide service-life test, air-purifying

respirators with canisters.TEB-APR-STP-0048C--Determination of sulfur 450

dioxide service-life test, powered air-

purifying respirators with cartridges.TEB-APR-STP-0048D--Determination of sulfur 450

dioxide service-life test, tight-fitting

powered air-purifying respirators with gas

mask canisters.RCT-APR-STP-0050--Determination of O- 2,400

chlorobenzylidene malononitrile (CS) service

life.TEB-APR-STP-0051--Determination of particulate 1,200

filter efficiency level for P100 series

filters against liquid particulates for non-

powered, air-purifying respirators.TEB-APR-STP-0052--Determination of particulate 1,200

filter efficiency level for P99 series filters

against liquid particulates for non-powered,

air-purifying respirators.TEB-APR-STP-0053--Determination of particulate 1,200

filter efficiency level for P95 series filters

against liquid particulates for non-powered,

air-purifying respirators.TEB-APR-STP-0054--Determination of particulate 1,200

filter efficiency level for R100 series

filters against liquid particulates for non-

powered, air-purifying respirators.TEB-APR-STP-0055--Determination of particulate 1,200

filter efficiency level for R99 series filters

against liquid particulates for non-powered,

air-purifying respirators.TEB-APR-STP-0056--Determination of particulate 1,200

filter efficiency level for R95 series filters

against liquid particulates for non-powered,

air-purifying respirators.TEB-APR-STP-0057--Determination of particulate 1,200

filter efficiency level for N100 series

filters against solid particulates for non-

powered, air-purifying respirators.TEB-APR-STP-0058--Determination of particulate 1,200

filter efficiency level for N99 series filters

against solid particulates for non-powered,

air-purifying respirators.TEB-APR-STP-0059--Determination of particulate 1,200

filter efficiency level for N95 series filters

against solid particulates for non-powered,

air-purifying respirators.RCT-APR-STP-0060--Determination of end-of- 300

service-life indicator drop.RCT-APR-STP-0061--Determination of end-of- 300

service-life indicator visibility.RCT-APR-STP-0062--Determination of nitrogen 750

dioxide service life.RCT-APR-STP-0063--Determination of facepiece 300

carbon dioxide and oxygen concentration

levels--tight fitting, powered air-purifying

respirators, with the blower unit running.

RCT-APR-STP-0064--Determination of facepiece 300

carbon dioxide and oxygen concentration

levels, tight fitting, powered air-purifying

respirators, with the blower unit off.RCT-APR-STP-0065--Determination of air flow 300

resistance, breath responsive, powered air-

purifying respirators.RCT-APR-STP-0066--Determination of end-of- 300

service-life indicator (ESLI).RCT-APR-STP-0067--Particulate respirator 1800

qualitative fit test utilizing saccharin or

bitrex solutions.------------------------------------------------------------------------

Air-Supplied Respirators------------------------------------------------------------------------RCT-ASR-STP-0100--Determination of strength of 150

hoses and couplings, type C and CE supplied-

air respirators.RCT-ASR-STP-0101--Determination of tightness of 150

hoses and couplings, type C and CE supplied-

air respirators.RCT-ASR-STP-0102--Determination of 150

nonkinkability of hoses, type C and CE

supplied-air respirators.RCT-ASR-STP-0103--Determination of gasoline 450

permeation of hoses and couplings, type C and

CE supplied-air respirators.RCT-ASR-STP-0104--Determination of air- 3,000

regulating valve 100,000 cycles performance,

demand and pressure-demand type C and CE

supplied-air respirators.RCT-ASR-STP-0105--Determination of airflow, 300

continuous flow type C and CE supplied-air

respirators.RCT-ASR-STP-0105A--Determination of airflow, 300

demand and pressure-demand type C and CE

supplied-air respirators.RCT-ASR-STP-0106--Determination of inhalation 150

airflow resistance, pressure-demand type C and

CE supplied-air respirators.RCT-ASR-STP-0107--Determination of exhalation 150

airflow resistance, pressure-demand type C and

CE supplied-air respirators.RCT-ASR-STP-0108--Determination of inhalation 150

airflow resistance, demand type C and CE

supplied-air respirators.RCT-ASR-STP-0109--Determination of exhalation 150

airflow resistance, demand type C and CE

supplied-air respirators.RCT-ASR-STP-0110--Determination of gas- 450

tightness test, isoamyl acetate (IAA), type C

and CE supplied-air respirators.RCT-ASR-STP-0111--Determination of air velocity 450

and noise levels--sound level, type C and CE

supplied-air respirators.RCT-ASR-STP-0112--Determination of the level of 450

protection provided by abrasive blast, type CE

supplied-air respirators using a challenge

aerosol of NaCl (sodium chloride) or corn oil.RCT-ASR-STP-0113--Determination of airflow 150

resistance--continuous-flow, type C and CE

supplied-air respirators.RCT-ASR-STP-0114--Determination of sound-level 450

measurement--escape, open-circuit self-

contained breathing apparatus using hoods or

helmets.RCT-ASR-STP-0115--Determination of rated 150

service time--constant-flow, escape, open-

circuit self-contained breathing apparatus.RCT-ASR-STP-0116--Determination of airflow 150

resistance--continuous-flow, escape, open-

circuit self-contained breathing apparatus

with hoods.RCT-ASR-STP-0117--Determination of positive 150

pressure--closed-circuit, pressure-demand,

self-contained breathing apparatus.RCT-ASR-STP-0118--Determination of low 1,200

temperature operation--minimum temperature per

applicant, open-circuit self-contained

breathing apparatus.RCT-ASR-STP-0119--Determination of low- 1,200

temperature operation--minimum temperature per

applicant, combination open-circuit self-

contained breathing apparatus and type C and

CE supplied-air respirators.RCT-ASR-STP-0120--Determination of positive 75

pressure--open-circuit, pressure-demand self-

contained breathing apparatus.RCT-ASR-STP-0121--Determination of rated 75

service time--open-circuit, demand and

pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0121A--Determination of rated 75

service time--closed-circuit, demand and

pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0122--Determination of exhalation 150

breathing resistance--open-circuit, demand and

pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0123--Determination of gas flow 150

measurements--open-circuit, demand and

pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0124--Determination of remaining 150

service-life indicator--open-circuit, demand

and pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0124A--Determination of alarm 150

pressure--closed-circuit, demand and pressure-

demand, self-contained breathing apparatus.RCT-ASR-STP-0125--Determination of gas 750

tightness--isoamyl acetate (IAA)--self-

contained breathing apparatus with facepieces

and mouthpieces.RCT-ASR-STP-0125A--Determination of gas 750

tightness--isoamyl acetate (IAA)--self-

contained breathing apparatus with hoods or

helmets.RCT-ASR-STP-0126--Determination of by-pass 150

valve flow--open-circuit, demand and pressure-

demand, self-contained breathing apparatus.RCT-ASR-STP-0127--Determination of by-pass 150

valve flow--closed-circuit, demand and

pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0128--Determination of accuracy of 150

gauge--self-contained breathing apparatus.

RCT-ASR-STP-0132--Determination of inhalation 150

breathing resistance--open-circuit, demand,

self-contained breathing apparatus.RCT-ASR-STP-0133--Determination of exhalation 150

breathing resistance--open-circuit, pressure-

demand, self-contained breathing apparatus

using two second stage regulators.RCT-ASR-STP-0134--Determination of gasoline 750

permeation test on breathing bags--closed-

circuit, self-contained breathing apparatus.RCT-ASR-STP-0135--Determination of inhalation 150

and exhalation breathing resistance--closed-

circuit, demand and pressure-demand, self-

contained breathing apparatus.RCT-ASR-STP-0136--Determination of demand gas 150

flow--closed-circuit, demand and pressure-

demand, self-contained breathing apparatus.RCT-ASR-STP-0137--Determination of continuous 450

gas flow on constant flow with demand flow--

closed-circuit, self-contained breathing

apparatus.RCT-ASR-STP-0138--Determination of safety 150

relief valve operation--closed-circuit, demand

and pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0139--Determination of facepiece 450

carbon dioxide concentrations--self-contained

breathing apparatus.RCT-ASR-STP-0140--Man tests--self-contained 3,000

breathing apparatus.RCT-ASR-STP-0141--Man test number 5--closed- 150

circuit, self-contained breathing apparatus.RCT-ASR-STP-0142--Determination of vibration 750

(Ro-Tap test) for man test number 1--escape,

closed-circuit, demand, self-contained

breathing apparatus.RCT-ASR-STP-0143--Determination of low- 1,200

temperature operation--minimum per

manufacturer--closed-circuit, self-contained

breathing apparatus.RCT-ASR-STP-0144--Determination of continuous 300

gas flow on constant flow--closed-circuit,

self-contained breathing apparatus.RCT-ASR-STP-0145--Determination of sound level 750

measurements for remaining service-life

indicators--self-contained breathing apparatus.RCT-ASR-STP-0146--Determination of diaphragm 300

over-pressurization--open-circuit, self-

contained breathing apparatus with belt

mounted regulators and breathing tubes.RCT-ASR-STP-0147--Determination of mode 150

transfer test--combination, open-circuit self-

contained breathing apparatus and supplied-air

respirators (SCBA/SAR).RCT-ASR-STP-0148--Determination of remote gauge 150

leak-flow test--open-circuit, demand and

pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0148A--Determination of remote 150

gauge leak-flow test--closed-circuit, demand

and pressure-demand, self-contained breathing

apparatus.RCT-ASR-STP-0155--Man test number 6--self- 2,400

contained breathing apparatus using liquefied

gas.------------------------------------------------------------------------

Chemical, Biological, Radiologic, Nuclear (CBRN) Air-Purifying and Air-

Supplied Respirators------------------------------------------------------------------------NIOSH/NPPTL administrative support for all CBRN 1,300

projects. RCT-CBRN-STP-0200, 0201--Determination of 6,000

open-circuit self-contained breathing

apparatus (SCBA) performance during dynamic

testing against chemical agents of sarin (GB)

vapor and distilled sulfur mustard (HD) vapor

and liquid--GB live agent testing. RCT-CBRN-STP-0200, 0201--Determination of 6,000

open-circuit self-contained breathing

apparatus (SCBA) performance during dynamic

testing against chemical agents sarin (GB)

vapor and of distilled sulfur mustard (HD)

vapor and liquid--HD live agent testing. RCT-CBRN-STP-0200, 0201--aerosol process TDA- 600

99M only.CET-APRS-STP-CBRN-0301--Determination of CBRN 1,000

organic vapor (cyclohexane) service-life test.CET-APRS-STP-CBRN-0302--Determination of CBRN 2,400

acid gases (cyanogen chloride) service-life

test.CET-APRS-STP-CBRN-0303--Determination of CBRN 2,400

acid gases (hydrogen cyanide) service-life

test.CET-APRS-STP-CBRN-0304--Determination of CBRN 1,400

acid gases (phosgene) service-life test.CET-APS-STP-CBRN-0305--Determination of CBRN 800

acid gases (hydrogen sulfide) service-life

test.CET-APRS-STP-CBRN-0306--Determination of CBRN 800

acid gases (sulfur dioxide) service-life test.CET-APRS-STP-CBRN-0307--Determination of CBRN 1,000

acid gases (ammonia) service-life test.CET-APRS-STP-CBRN-0308--Determination of CBRN 1,200

nitrogen oxide gases (nitrogen dioxide)

service-life test.CET-APRS-STP-CBRN-0309--Determination of CBRN 1,000

hydride gases (phosphine) service-life test.CET-APRS-STP-CBRN-0310--Determination of CBRN 1,000

formaldehyde service-life test, air-purifying

respirators.CET-APRS-STP-CBRN-0311--Laboratory durability 20,000

conditioning process for environmental,

transportation and rough handling use

conditions on chemical, biological,

radiological, and nuclear (CBRN) respiratory

protective devices (RPD) standard conditioning

procedure (SCP)--US Army Research Development

and Engineering Command (RDECOM) environmental

conditioning.CET-APRS-STP-CBRN-0311--NPPTL environmental 16,000

conditioning.CET-APRS-STP-CBRN-0311--RDECOM modified 16,000

environmental conditioning--minus 125

canisters.CET-APRS-STP-CBRN-0311--NPPTL modified 8,000

environmental conditioning--minus 125

canisters.CET-APRS-STP-CBRN-0312--Determination of field 1,000

of view for full facepiece chemical biological

radiological nuclear (CBRN) respiratory

protective devices (RPD).TEB-CBRN-APR-STP-0313--Determination of 5,000

communication performance test for speech

conveyance and intelligibility of chemical

biological radiological and nuclear (CBRN)

full-facepiece air-purifying respirator.CET-APRS-STP-CBRN-0314--Determination of lens 3,000

fogging on full facepiece chemical biological

radiological nuclear (CBRN) air-purifying

respirator.CET-APRS-STP-CBRN-0316--Determination of haze, 2,000

luminous-transmittance, and abrasion-

resistance properties of the primary lens

system material for full-facepiece respiratory

protective devices (RPD).

 RCT-CBRN-APR-STP-0350--Determination of full 7,000

facepiece, tight-fitting, negative-pressure,

air-purifying respirator (APR) performance

during dynamic testing against the chemical

agent vapor sarin (GB)--qualifier live agent

testing (QLAT) only. RCT-CBRN-APR-STP-0350--remainder live agent 6,000

testing (RLAT). RCT-CBRN-APR-STP-0351--Determination of full- 7,000

facepiece, tight-fitting, negative-pressure,

air-purifying respirator (APR) performance

during dynamic testing against chemical agent

distilled sulfur mustard (HD) vapor and liquid

CBRN--qualifier live agent testing (QLAT) only. RCT-CBRN-APR-STP-0351--remainder live agent 6,000

testing (RLAT). RCT-CBRN-APR-STP-0350 and RCT-CBRN-APR-STP- 600

0351--aerosol process TDA-99M.TEB-CBRN-APR-STP-0352--Determination of 20,000

laboratory respirator protection level (LRPL)

values for CBRN self-contained breathing

apparatus (SCBA) facepieces or CBRN air-

purifying respirator (APR)--LRPL.TEB-CBRN-APR-STP-0352--partial laboratory 16,000

respirator protection level (LRPL) (in cases

where failure occurs with less than 50% of

subjects tested).* TEB-CBRN-APR-STP-0353--Weight and diameter... 200CET-APRS-STP-CBRN-0401--Determination of CBRN 1,000

organic vapor (cyclohexane) service-life test,

air-purifying escape respirators.CET-APRS-STP-CBRN-0402--Determination of CBRN 2,400

acid gases (cyanogen chloride) service-life

test, air-purifying escape respirators.CET-APRS-STP-CBRN-0403--Determination of CBRN 2,400

acid gases (hydrogen cyanide) service-life

test, air-purifying escape respirators.CET-APRS-STP-CBRN-0404--Determination of CBRN 1,400

acid gases (phosgene) service-life test, air-

purifying escape respirators.CET-APRS-STP-CBRN-0405--Determination of CBRN 800

acid gases (hydrogen sulfide) service-life

test, air-purifying escape respirators.CET-APRS-STP-CBRN-0406--Determination of CBRN 800

acid gases (sulfur dioxide) service-life test,

air-purifying escape respirators.CET-APRS-STP-CBRN-0407--Determination of CBRN 1,000

base gases (ammonia) service-life test, air-

purifying escape respirators.CET-APRS-STP-CBRN-0408--Determination of CBRN 1,200

nitrogen oxide gases (nitrogen dioxide)

service-life test, air-purifying escape

respirators.CET-APRS-STP-CBRN-0409--Determination of CBRN 1,000

hydride gases (phosphine) service-life test,

air-purifying escape respirators.CET-APRS-STP-CBRN-0410--Determination of CBRN 1,000

formaldehyde service-life test, air-purifying

escape respirators.CET-APRS-STP-CBRN-0411--Laboratory durability 22,000

conditioning process for environmental,

transportation and rough handling use

conditions on chemical, biological,

radiological and nuclear (CBRN) (air-purifying

or self-contained) escape respirator--RDECOM

environmental conditioning.CET-APRS-STP-CBRN-0411--NPPTL environmental 20,000

conditioning.* CET-APRS-STP-CBRN-0414--Fogging............. 4,000* CET-APRS-STP-CBRN-0417--Flammability, heat 14,000

resistance. CET-APRS-STP-CBRN-0450--Determination of 7,000

chemical agent permeation and penetration

resistance performance against sarin (GB)

vapor of chemical, biological, radiological,

and nuclear (CBRN) air-purifying escape

respirator--qualifier live agent testing

(QLAT) only. CET-APRS-STP-CBRN-0450--remainder live agent 6,000

testing (RLAT). CET-APRS-STP-CBRN-0451--Determination of 7,000

chemical agent permeation and penetration

resistance performance against sulfur mustard

(HD) liquid and vapor of the chemical,

biological, radiological, and nuclear (CBRN)

air-purifying escape respirator--qualifier

live agent testing (QLAT) only. CET-APRS-STP-CBRN-0451--remainder live agent 6,000

testing (RLAT). CET-APRS-STP-CBRN-0450 and CET-APRS-STP-CBRN- 600

0451--aerosol process TDA-99M.TEB-CBRN-APR-STP-0452--Determination of 20,000

laboratory respirator protection level (LRPL)

values for CBRN air-purifying escape

respirator--LRPL.TEB-CBRN-APR-STP-0452--partial LRPL............ 16,000CET-APRS-STP-CBRN-0454--Determination of human 3,500

subject breathing gas (HSBG) concentrations

(carbon dioxide and oxygen) for chemical,

biological, radiological and nuclear (CBRN)

air-purifying escape respirator.* CET-APRS-STP-CBRN-0455--Human subject 6,000

breathing gas test.CET-APRS-STP-CBRN-0456--Determination of (\1\)

practical performance level for chemical,

biological, radiological and nuclear (CBRN)

(air-purifying or self-contained) escape

respirator.CET-APRS-STP-CBRN-0499--Determination of ( \1\)

donning effectiveness of chemical, biological,

radiological and nuclear (CBRN) (air-purifying

or self-contained) escape respirator.TEB-CBRN-STP-0501--Determination of CBRN 1,000

organic vapor (cyclohexane) service-life test,

tight-fitting powered air-purifying

respirators (PAPR).TEB-CBRN-STP-0502--Determination of CBRN acid 2,400

gases (cyanogen chloride) service-life test,

tight-fitting powered air-purifying

respirators (PAPR).TEB-CBRN-STP-0503--Determination of CBRN acid 2,400

gases (hydrogen cyanide) service-life test,

tight-fitting powered air-purifying

respirators (PAPR).TEB-CBRN-STP-0504--Determination of CBRN acid 1,400

gases (phosgene) service-life test, tight-

fitting powered air-purifying respirators

(PAPR).TEB-CBRN-STP-0505--Determination of CBRN acid 800

gases (hydrogen sulfide) service-life test,

tight-fitting powered air-purifying

respirators (PAPR).TEB-CBRN-STP-0506--Determination of CBRN acid 800

gases (sulfur dioxide) service-life test,

tight-fitting powered air-purifying

respirators (PAPR).

TEB-CBRN-STP-0507--Determination of CBRN base 1,000

gases (ammonia) service-life test, tight-

fitting powered air-purifying respirators

(PAPR).TEB-CBRN-STP-0508--Determination of CBRN 1,200

nitrogen oxide gases (nitrogen dioxide)

service-life test, tight-fitting powered air-

purifying respirators (PAPR).TEB-CBRN-STP-0509--Determination of CBRN 1,000

hydride gases (phosphine) service-life test,

tight-fitting powered air-purifying

respirators (PAPR).TEB-CBRN-STP-0510--Determination of CBRN 1,000

formaldehyde service-life test, tight-fitting

powered air-purifying respirators (PAPR).TEB-APR-STP-0511-CBRN--Determination of CBRN 1,000

organic vapor (cyclohexane) service-life test,

loose-fitting powered air-purifying

respirators (PAPR).TEB-APR-STP-0512-CBRN--Determination of CBRN 2,400

acid gases (cyanogen chloride) service-life

test, loose-fitting powered air-purifying

respirators (PAPR).TEB-APR-STP-0513-CBRN--Determination of CBRN 2,400

acid gases (hydrogen cyanide) service-life

test, loose-fitting powered air-purifying

respirators (PAPR).TEB-APR-STP-0514-CBRN--Determination of CBRN 1,400

acid gases (phosgene) service-life test, loose-

fitting powered air-purifying respirators

(PAPR).TEB-APR-0515-CBRN--Determination of CBRN acid 800

gases (hydrogen sulfide) service-life test,

loose-fitting powered air-purifying

respirators (PAPR).TEB-APR-STP-0516-CBRN--Determination of CBRN 800

acid gases (sulfur dioxide) service-life test,

loose-fitting powered air-purifying

respirators (PAPR).TEB-APR-STP-0517-CBRN--Determination of CBRN 1,000

base gases (ammonia) service-life test, loose-

fitting powered air-purifying respirators

(PAPR).TEB-APR-STP-0518-CBRN--Determination of CBRN 1,200

nitrogen oxide gases (nitrogen dioxide)

service-life test, loose-fitting powered air-

purifying respirators (PAPR).TEB-APR-STP-0519-CBRN--Determination of CBRN 1,000

hydride gases (phosphine) service-life test,

loose-fitting powered air-purifying

respirators (PAPR).TEB-APR-STP-0520-CBRN--Determination of CBRN 1,000

formaldehyde service-life test, loose-fitting

powered air-purifying respirators (PAPR).NPPTL-STP-CBRN-PAPR-0550--Determination of CBRN 7,000

powered air-purifying respirator (PAPR)

performance during dynamic testing against the

chemical agent vapor sarin (GB) chemical,

biological, radiological and nuclear (CBRN)

standard testing procedure (STP).NPPTL-STP-CBRN-PAPR-0551--Determination of 7,000

CBRN, powered air-purifying respirator (PAPR)

performance during dynamic testing against

chemical agent distilled sulfur mustard (HD)

vapor and distilled sulfur mustard (HD) liquid

chemical, biological, radiological, and

nuclear (CBRN) standard testing procedure

(STP).TEB-CBRN-APR-STP-0552--Determination of 20,000

laboratory respirator protection level (LRPL)

values for CBRN tight-fitting powered air-

purifying respirator (PAPR).TEB-CBRN-APR-STP-0553--Determination of 20,000

laboratory respiratory protection level (LRPL)

values for CBRN loose-fitting powered air-

purifying respirator (PAPR).------------------------------------------------------------------------

New and Unspecified Tests------------------------------------------------------------------------This category is to be used for new, on-going, (\2\)

tests which are developed between revisions of

the test fee schedule or for special, one-time

tests which are required for respirators with

unique features (per 42 CFR 84.63).------------------------------------------------------------------------* Draft test procedure in place, but final STP has not been published. Test is conducted by U.S. Army Research, Development and Engineering

Command Edgewood Chemical Biological Center (ECBC).\1\ No Fee, done as part of LRPL (TEB-CBRN-APR-STP-0452).\2\ $500/day + the actual cost of non-NPPTL staff (typically medical

staff and test subjects). [80 FR 3908, Jan. 26, 2015]