(a) Three respirators with cartridges containing, or having attached to them, filters for protection against dusts, fumes, and mists, except the mists of paints, lacquers, and enamels, will be tested in accordance with the provisions of Sec. 84.1157(f).
(b) In addition to the test requirements set forth in paragraph (a) of this section, three such respirators will be tested, as appropriate, in accordance with the provisions of Sec. Sec. 84.1141 through 84.1152; however, the maximum allowable resistance of complete dust, fume, and mist, and gas, vapor, or gas and vapor chemical cartridge respirators shall not exceed the maximum allowable limits set forth in Sec. 84.1157(a)(2).
Sec. Tables to Subpart KK of Part 84
Table 12--Facepiece Test Requirements
[42 CFR Part 84, Subpart KK]------------------------------------------------------------------------
Pressure Isoamyl acetate test
Respirator types tightness ---------------------------
test \1\ 84.1141 84.1142------------------------------------------------------------------------Dusts: Air Contamination Level X
not less than 0.05 mg/M\3\ or
2 mppcf......................Fumes: Air Contamination Level X X
not less than 0.05 mg/M\3\...Mists: Air Contamination Level X
not less than 0.05 mg/M\3\ or
2 mppcf......................Dusts, Fumes, and Mists: Air X ............ X
Contamination Level less than
0.05 mg/M\3\ or 2 mppcf, and
radionuclides................Radon daughters............... X XAsbestos-containing dusts and X
mists........................------------------------------------------------------------------------\1\ Test is required only where applicable.
Table 13--Air-Purifying and Powered Air-Purifying Respirator Filter Tests Required for Approval
[42 CFR Part 84, Subpart KK]----------------------------------------------------------------------------------------------------------------
Silica dust tests
Respirator types ------------------------------------------ Lead fume Silica mist DOP test
84.1144 84.1145 84.1152 test 84.1146 test 84.1147 84.1151----------------------------------------------------------------------------------------------------------------Dusts: Air Contamination X
Level not less than 0.05 mg/
M\3\ or 2 mppcf............Fumes: Air Contamination ............ ............ ............ X
Level not less than 0.05 mg/
M\3\.......................Mists: Air Contamination ............ ............ ............ ............ X
Level not less than 0.05 mg/
M\3\ or 2 mppcf............Dusts, Fumes, and Mists: Air ............ ............ X ............ ............ X
Contamination Level less
than 0.05 mg/M\3\ or 2
mppcf, and radionuclides...Radon daughters............. \1\ X ............ ............ ............ \2\ XAsbestos-containing dusts \2\ X ............ ............ ............ \3\ X
and mists..................Single use dust and mist ............ \3\ X ............ ............ \3\ X
respirators................----------------------------------------------------------------------------------------------------------------\1\ For resistance only.\2\ For penetration only.\3\ Test required only where applicable.
Table 14--Carbon Tetrachloride Bench Tests and Requirements for Canisters and Cartridges
[42 CFR part 84, Subpart KK]----------------------------------------------------------------------------------------------------------------
Test Minimum
Type of pesticide respirator concentration Flow rate Number of life
p.p.m. CCl4 l.p.m. tests minutes \1\----------------------------------------------------------------------------------------------------------------Chest-mounted or back-mounted gas mask (as received)...... 20,000 64 3 12Chest-mounted or back-mounted gas mask (equilibrated)..... 20,000 32 4 12Chin-style gas mask (as received)......................... 5,000 64 3 12Chin-style gas mask (equilibrated)........................ 5,000 32 4 12Chemical Cartridge respirator (as received)............... 1,000 64 3 50Chemical cartridge respirator (equilibrated).............. 1,000 32 4 50Powered air-purifying respirator (tight-fitting facepiece, 1,000 \2\ 115 3 50
as received).............................................Powered air-purifying respirator (tight-fitting facepiece, 1,000 \2\ 115 4 25
equilibrated)............................................Powered air-purifying respirator (loose-fitting hood or 1,000 \3\ 170 3 50
helmet, as received).....................................Powered air-purifying respirator (loose-fitting hood or 1,000 \3\ 170 4 25
helmet, equilibrated)....................................----------------------------------------------------------------------------------------------------------------\1\ Minimum life will be determined at 5 p.p.m. leakage.\2\ The flow rate shall be the effective flow rate of the device, but shall be not less than 115 l.p.m.\3\ The flow rate shall be the effective flow rate of the device, but shall be not less than 170 l.p.m. Sec. Appendix A to Part 84--Annual (Fixed) Respirator Certification Fees
Respirator Certification Fee Schedule A--Annual (Fixed) Fees
[Implemented on May 26, 2015]----------------------------------------------------------------------------------------------------------------
Fee type Legal citation Amount Due date----------------------------------------------------------------------------------------------------------------Maintenance of Product Performance 42 CFR 84.20(b)(5)... Annual Upon
(product audit). fee: $761 per each billing from NIOSH.\1\
approval holder.
October.
Variable fee: As billed
by NIOSH based on the
respirators chosen to be
tested each year.Records Maintenance............... 42 CFR 84.20(b)(1)... $50 for all listed \2\ Upon
approvals on file with billing from NIOSH.\1\
NIOSH on July 1st of each
year. October (beginning in
2015).Quality Assurance Maintenance 42 CFR 84.20(b)(4)... Annual Upon
(site audit). fee: $3,000 per every billing from NIOSH.\1\
manufacturing site
registered with NIOSH. October (beginning in
2015).
Variable fee: \3\.
[squarf] 1 day domestic
audit--$2,500 per site.
[squarf] 2 day domestic
audit--$5,000 per site.
[squarf] 1 day
international audit--
$7,500 per site.
[squarf] 2 day
international audit--
$10,000 per site.
Maintenance of Testing and 42 CFR 84.20(b)(2)... $34 per every listed \2\ Upon
Approval Facilities. approval on file with billing from NIOSH.\1\
NIOSH on July 1st of each
applicable year. October (beginning in
2015).Maintenance of Test Equipment..... 42 CFR 84.20(b)(2)... $36 per every active \4\ Upon
approval on file with billing from NIOSH.\1\
NIOSH on July 1st of each
applicable year. October (beginning in
2015).----------------------------------------------------------------------------------------------------------------\1\ For the first year that annual fees are in effect, NIOSH will provide manufacturers with a pre-invoice/
advanced billing/invoice preview no later than July 1, 2015. The actual invoice will be sent in September
2015.\2\ ``Listed'' approvals include all active and obsolete approvals. The Certified Equipment List (CEL) reflects
the current listed approvals maintained by NIOSH. See http://www.cdc.gov/niosh/npptl/topics/respirators/CEL/
default.html.\3\ Applies to design as well as manufacturing sites.\4\ Does not include obsolete approvals. [80 FR 3908, Jan. 26, 2015]
Sec. Appendix B to Part 84--Application-Based Respirator Certification
Fees
Respirator Certification Fee Schedule B--Application-Based Fees
[Implemented on May 26, 2015]----------------------------------------------------------------------------------------------------------------
Fee type Legal citation Amount Due date----------------------------------------------------------------------------------------------------------------Application....................... 42 CFR 84.20(b)(1)... $200 per application Upon receipt of any
submitted. application request.Approval.......................... 42 CFR 84.20(b)(1)... $100 per each certificate Upon completion of the
of approval issued. application and granting
of an approval number.Approval Modification............. 42 CFR 84.20(b)(1)... $50 per each certificate Upon completion of the
of approval modified. application and issuing
a modified approval.Site Qualification................ 42 CFR 84.20(b)(3)... Upon agreement on the
Existing approval holder, date of the site
paper review: $400 per qualification
each request to inspect examination.
new production facility.
Non-
approval holders:.
[squarf] Domestic site
visit--$2,500.
[squarf] International
site visit--$7,500.---------------------------------------------------------------------------------------------------------------- ------------------------------------------------------------------------
Standard Test Procedure Fee ($)------------------------------------------------------------------------
Testing Fees------------------------------------------------------------------------Descriptor:.................................... For testing
respirators.------------------------------------------------------------------------Amount:........................................ See below.------------------------------------------------------------------------Basis:......................................... Per each test.------------------------------------------------------------------------Due date:...................................... Upon initiation of
testing.------------------------------------------------------------------------
Air-Purifying Respirators------------------------------------------------------------------------TEB-APR-STP-0001 Determination of particulate 150
filter penetration (PAPR).RCT-APR-STP-0003--Determination of exhalation 150
resistance.TEB-APR-STP-0004--Determination of exhalation 300
valve leakage.TEB-APR-STP-0005--Determination of qualitative 1,800
isoamyl acetate (IAA) facepiece fit test.TEB-APR-STP-0005A--Determination of qualitative 1,800
isoamyl acetate (IAA) facepiece fit test.TEB-APR-STP-0006--Determination of qualitative 1,800
isoamyl acetate (IAA) facepiece fit test.TEB-APR-STP-0007--Determination of inhalation 150
resistance.RCT-APR-STP-0012--Determination of air flow for 150
powered air-purifying respirators.RCT-APR-STP-0014--Determination of leakage of 300
drinking tube and accessories for respirator
facepieces.RCT-APR-STP-0025--Determination of silica dust 1,200
loading test for powered air-purifying
respirator filters.RCT-APR-STP-0030--Determination of noise level 450
test, powered air-purifying respirator with
hoods or helmets.TEB-APR-STP-0033A--Determination of ammonia 750
service-life test, air-purifying respirators
with cartridges.TEB-APR-STP-0033B--Determination of ammonia 750
service-life test, air-purifying respirators
with canisters.TEB-APR-STP-0033C--Determination of ammonia 750
service-life test, powered air-purifying
respirators with cartridges.
TEB-APR-STP-0033D--Determination of ammonia 750
service-life test, tight-fitting powered air-
purifying respirators with gas mask
canister(s).RCT-APR-STP-0034--Carbon monoxide service life. 750RCT-APR-STP-0035--Determination of chlorine 750
service life.RCT-APR-STP-0036--Determination of chlorine 750
dioxide service life.RCT-APR-STP-0037--Determination of a- 2,400
chloroacetophenone (CN) service life.RCT-APR-STP-0038--Determination of ethylene 450
oxide service life.TEB-APR-STP-0039A--Determination of 750
formaldehyde service-life test, air-purifying
respirators with cartridges.TEB-APR-STP-0039B--Determination of 750
formaldehyde service-life test, air-purifying
respirators with canisters.TEB-APR-STP-0039C--Determination of 750
formaldehyde service-life test, powered air-
purifying respirators with cartridges.RCT-APR-STP-0040--Determination of hydrogen 500
chloride service life.RCT-APR-STP-0041--Determination of hydrogen 1,800
cyanide service life.RCT-APR-STP-0042--Determination of hydrogen 750
fluoride service life.TEB-APR-STP-0043A--Determination of hydrogen 750
sulfide service-life test, air-purifying
respirators with cartridges.TEB-APR-STP-0043B--Determination of hydrogen 750
sulfide service-life test, air-purifying
respirators with canisters.TEB-APR-STP-0043C--Determination of hydrogen 750
sulfide service-life test, powered air-
purifying respirators with cartridges.RCT-APR-STP-0044--Determination of mercury 2,400
vapor service life.TEB-APR-STP-0045A--Determination of methylamine 450
service-life test, air-purifying respirators
with cartridges.TEB-APR-STP-0045B--Determination of methylamine 450
service-life test, air-purifying respirators
with canisters.TEB-APR-STP-0045C--Determination of methylamine 450
service-life test, powered air-purifying
respirators with cartridges.TEB-APR-STP-0045D--Determination of methylamine 450
service-life test, tight-fitting powered air-
purifying respirators with gas mask
canister(s).TEB-APR-STP-0046A--Determination of organic 450
vapor (carbon tetrachloride) service-life
test, air-purifying respirators with
cartridges.TEB-APR-STP-0046B--Determination of organic 450
vapor (carbon tetrachloride) service-life
test, air-purifying respirators with
cartridges.TEB-APR-STP-0046C--Determination of organic 450
vapor (carbon tetrachloride) service-life
test, powered air-purifying respirators with
cartridges.TEB-APR-STP-0046D--Determination of organic 450
vapor (carbon tetrachloride) service-life
test, tight-fitting powered air-purifying
respirators with gas mask canister(s).RCT-APR-STP-0047--Determination of phosphine 750
service life.TEB-APR-STP-0048A--Determination of sulfur 450
dioxide service-life test, air-purifying
respirators with cartridges.TEB-APR-STP-0048B--Determination of sulfur 450
dioxide service-life test, air-purifying
respirators with canisters.TEB-APR-STP-0048C--Determination of sulfur 450
dioxide service-life test, powered air-
purifying respirators with cartridges.TEB-APR-STP-0048D--Determination of sulfur 450
dioxide service-life test, tight-fitting
powered air-purifying respirators with gas
mask canisters.RCT-APR-STP-0050--Determination of O- 2,400
chlorobenzylidene malononitrile (CS) service
life.TEB-APR-STP-0051--Determination of particulate 1,200
filter efficiency level for P100 series
filters against liquid particulates for non-
powered, air-purifying respirators.TEB-APR-STP-0052--Determination of particulate 1,200
filter efficiency level for P99 series filters
against liquid particulates for non-powered,
air-purifying respirators.TEB-APR-STP-0053--Determination of particulate 1,200
filter efficiency level for P95 series filters
against liquid particulates for non-powered,
air-purifying respirators.TEB-APR-STP-0054--Determination of particulate 1,200
filter efficiency level for R100 series
filters against liquid particulates for non-
powered, air-purifying respirators.TEB-APR-STP-0055--Determination of particulate 1,200
filter efficiency level for R99 series filters
against liquid particulates for non-powered,
air-purifying respirators.TEB-APR-STP-0056--Determination of particulate 1,200
filter efficiency level for R95 series filters
against liquid particulates for non-powered,
air-purifying respirators.TEB-APR-STP-0057--Determination of particulate 1,200
filter efficiency level for N100 series
filters against solid particulates for non-
powered, air-purifying respirators.TEB-APR-STP-0058--Determination of particulate 1,200
filter efficiency level for N99 series filters
against solid particulates for non-powered,
air-purifying respirators.TEB-APR-STP-0059--Determination of particulate 1,200
filter efficiency level for N95 series filters
against solid particulates for non-powered,
air-purifying respirators.RCT-APR-STP-0060--Determination of end-of- 300
service-life indicator drop.RCT-APR-STP-0061--Determination of end-of- 300
service-life indicator visibility.RCT-APR-STP-0062--Determination of nitrogen 750
dioxide service life.RCT-APR-STP-0063--Determination of facepiece 300
carbon dioxide and oxygen concentration
levels--tight fitting, powered air-purifying
respirators, with the blower unit running.
RCT-APR-STP-0064--Determination of facepiece 300
carbon dioxide and oxygen concentration
levels, tight fitting, powered air-purifying
respirators, with the blower unit off.RCT-APR-STP-0065--Determination of air flow 300
resistance, breath responsive, powered air-
purifying respirators.RCT-APR-STP-0066--Determination of end-of- 300
service-life indicator (ESLI).RCT-APR-STP-0067--Particulate respirator 1800
qualitative fit test utilizing saccharin or
bitrex solutions.------------------------------------------------------------------------
Air-Supplied Respirators------------------------------------------------------------------------RCT-ASR-STP-0100--Determination of strength of 150
hoses and couplings, type C and CE supplied-
air respirators.RCT-ASR-STP-0101--Determination of tightness of 150
hoses and couplings, type C and CE supplied-
air respirators.RCT-ASR-STP-0102--Determination of 150
nonkinkability of hoses, type C and CE
supplied-air respirators.RCT-ASR-STP-0103--Determination of gasoline 450
permeation of hoses and couplings, type C and
CE supplied-air respirators.RCT-ASR-STP-0104--Determination of air- 3,000
regulating valve 100,000 cycles performance,
demand and pressure-demand type C and CE
supplied-air respirators.RCT-ASR-STP-0105--Determination of airflow, 300
continuous flow type C and CE supplied-air
respirators.RCT-ASR-STP-0105A--Determination of airflow, 300
demand and pressure-demand type C and CE
supplied-air respirators.RCT-ASR-STP-0106--Determination of inhalation 150
airflow resistance, pressure-demand type C and
CE supplied-air respirators.RCT-ASR-STP-0107--Determination of exhalation 150
airflow resistance, pressure-demand type C and
CE supplied-air respirators.RCT-ASR-STP-0108--Determination of inhalation 150
airflow resistance, demand type C and CE
supplied-air respirators.RCT-ASR-STP-0109--Determination of exhalation 150
airflow resistance, demand type C and CE
supplied-air respirators.RCT-ASR-STP-0110--Determination of gas- 450
tightness test, isoamyl acetate (IAA), type C
and CE supplied-air respirators.RCT-ASR-STP-0111--Determination of air velocity 450
and noise levels--sound level, type C and CE
supplied-air respirators.RCT-ASR-STP-0112--Determination of the level of 450
protection provided by abrasive blast, type CE
supplied-air respirators using a challenge
aerosol of NaCl (sodium chloride) or corn oil.RCT-ASR-STP-0113--Determination of airflow 150
resistance--continuous-flow, type C and CE
supplied-air respirators.RCT-ASR-STP-0114--Determination of sound-level 450
measurement--escape, open-circuit self-
contained breathing apparatus using hoods or
helmets.RCT-ASR-STP-0115--Determination of rated 150
service time--constant-flow, escape, open-
circuit self-contained breathing apparatus.RCT-ASR-STP-0116--Determination of airflow 150
resistance--continuous-flow, escape, open-
circuit self-contained breathing apparatus
with hoods.RCT-ASR-STP-0117--Determination of positive 150
pressure--closed-circuit, pressure-demand,
self-contained breathing apparatus.RCT-ASR-STP-0118--Determination of low 1,200
temperature operation--minimum temperature per
applicant, open-circuit self-contained
breathing apparatus.RCT-ASR-STP-0119--Determination of low- 1,200
temperature operation--minimum temperature per
applicant, combination open-circuit self-
contained breathing apparatus and type C and
CE supplied-air respirators.RCT-ASR-STP-0120--Determination of positive 75
pressure--open-circuit, pressure-demand self-
contained breathing apparatus.RCT-ASR-STP-0121--Determination of rated 75
service time--open-circuit, demand and
pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0121A--Determination of rated 75
service time--closed-circuit, demand and
pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0122--Determination of exhalation 150
breathing resistance--open-circuit, demand and
pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0123--Determination of gas flow 150
measurements--open-circuit, demand and
pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0124--Determination of remaining 150
service-life indicator--open-circuit, demand
and pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0124A--Determination of alarm 150
pressure--closed-circuit, demand and pressure-
demand, self-contained breathing apparatus.RCT-ASR-STP-0125--Determination of gas 750
tightness--isoamyl acetate (IAA)--self-
contained breathing apparatus with facepieces
and mouthpieces.RCT-ASR-STP-0125A--Determination of gas 750
tightness--isoamyl acetate (IAA)--self-
contained breathing apparatus with hoods or
helmets.RCT-ASR-STP-0126--Determination of by-pass 150
valve flow--open-circuit, demand and pressure-
demand, self-contained breathing apparatus.RCT-ASR-STP-0127--Determination of by-pass 150
valve flow--closed-circuit, demand and
pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0128--Determination of accuracy of 150
gauge--self-contained breathing apparatus.
RCT-ASR-STP-0132--Determination of inhalation 150
breathing resistance--open-circuit, demand,
self-contained breathing apparatus.RCT-ASR-STP-0133--Determination of exhalation 150
breathing resistance--open-circuit, pressure-
demand, self-contained breathing apparatus
using two second stage regulators.RCT-ASR-STP-0134--Determination of gasoline 750
permeation test on breathing bags--closed-
circuit, self-contained breathing apparatus.RCT-ASR-STP-0135--Determination of inhalation 150
and exhalation breathing resistance--closed-
circuit, demand and pressure-demand, self-
contained breathing apparatus.RCT-ASR-STP-0136--Determination of demand gas 150
flow--closed-circuit, demand and pressure-
demand, self-contained breathing apparatus.RCT-ASR-STP-0137--Determination of continuous 450
gas flow on constant flow with demand flow--
closed-circuit, self-contained breathing
apparatus.RCT-ASR-STP-0138--Determination of safety 150
relief valve operation--closed-circuit, demand
and pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0139--Determination of facepiece 450
carbon dioxide concentrations--self-contained
breathing apparatus.RCT-ASR-STP-0140--Man tests--self-contained 3,000
breathing apparatus.RCT-ASR-STP-0141--Man test number 5--closed- 150
circuit, self-contained breathing apparatus.RCT-ASR-STP-0142--Determination of vibration 750
(Ro-Tap test) for man test number 1--escape,
closed-circuit, demand, self-contained
breathing apparatus.RCT-ASR-STP-0143--Determination of low- 1,200
temperature operation--minimum per
manufacturer--closed-circuit, self-contained
breathing apparatus.RCT-ASR-STP-0144--Determination of continuous 300
gas flow on constant flow--closed-circuit,
self-contained breathing apparatus.RCT-ASR-STP-0145--Determination of sound level 750
measurements for remaining service-life
indicators--self-contained breathing apparatus.RCT-ASR-STP-0146--Determination of diaphragm 300
over-pressurization--open-circuit, self-
contained breathing apparatus with belt
mounted regulators and breathing tubes.RCT-ASR-STP-0147--Determination of mode 150
transfer test--combination, open-circuit self-
contained breathing apparatus and supplied-air
respirators (SCBA/SAR).RCT-ASR-STP-0148--Determination of remote gauge 150
leak-flow test--open-circuit, demand and
pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0148A--Determination of remote 150
gauge leak-flow test--closed-circuit, demand
and pressure-demand, self-contained breathing
apparatus.RCT-ASR-STP-0155--Man test number 6--self- 2,400
contained breathing apparatus using liquefied
gas.------------------------------------------------------------------------
Chemical, Biological, Radiologic, Nuclear (CBRN) Air-Purifying and Air-
Supplied Respirators------------------------------------------------------------------------NIOSH/NPPTL administrative support for all CBRN 1,300
projects. RCT-CBRN-STP-0200, 0201--Determination of 6,000
open-circuit self-contained breathing
apparatus (SCBA) performance during dynamic
testing against chemical agents of sarin (GB)
vapor and distilled sulfur mustard (HD) vapor
and liquid--GB live agent testing. RCT-CBRN-STP-0200, 0201--Determination of 6,000
open-circuit self-contained breathing
apparatus (SCBA) performance during dynamic
testing against chemical agents sarin (GB)
vapor and of distilled sulfur mustard (HD)
vapor and liquid--HD live agent testing. RCT-CBRN-STP-0200, 0201--aerosol process TDA- 600
99M only.CET-APRS-STP-CBRN-0301--Determination of CBRN 1,000
organic vapor (cyclohexane) service-life test.CET-APRS-STP-CBRN-0302--Determination of CBRN 2,400
acid gases (cyanogen chloride) service-life
test.CET-APRS-STP-CBRN-0303--Determination of CBRN 2,400
acid gases (hydrogen cyanide) service-life
test.CET-APRS-STP-CBRN-0304--Determination of CBRN 1,400
acid gases (phosgene) service-life test.CET-APS-STP-CBRN-0305--Determination of CBRN 800
acid gases (hydrogen sulfide) service-life
test.CET-APRS-STP-CBRN-0306--Determination of CBRN 800
acid gases (sulfur dioxide) service-life test.CET-APRS-STP-CBRN-0307--Determination of CBRN 1,000
acid gases (ammonia) service-life test.CET-APRS-STP-CBRN-0308--Determination of CBRN 1,200
nitrogen oxide gases (nitrogen dioxide)
service-life test.CET-APRS-STP-CBRN-0309--Determination of CBRN 1,000
hydride gases (phosphine) service-life test.CET-APRS-STP-CBRN-0310--Determination of CBRN 1,000
formaldehyde service-life test, air-purifying
respirators.CET-APRS-STP-CBRN-0311--Laboratory durability 20,000
conditioning process for environmental,
transportation and rough handling use
conditions on chemical, biological,
radiological, and nuclear (CBRN) respiratory
protective devices (RPD) standard conditioning
procedure (SCP)--US Army Research Development
and Engineering Command (RDECOM) environmental
conditioning.CET-APRS-STP-CBRN-0311--NPPTL environmental 16,000
conditioning.CET-APRS-STP-CBRN-0311--RDECOM modified 16,000
environmental conditioning--minus 125
canisters.CET-APRS-STP-CBRN-0311--NPPTL modified 8,000
environmental conditioning--minus 125
canisters.CET-APRS-STP-CBRN-0312--Determination of field 1,000
of view for full facepiece chemical biological
radiological nuclear (CBRN) respiratory
protective devices (RPD).TEB-CBRN-APR-STP-0313--Determination of 5,000
communication performance test for speech
conveyance and intelligibility of chemical
biological radiological and nuclear (CBRN)
full-facepiece air-purifying respirator.CET-APRS-STP-CBRN-0314--Determination of lens 3,000
fogging on full facepiece chemical biological
radiological nuclear (CBRN) air-purifying
respirator.CET-APRS-STP-CBRN-0316--Determination of haze, 2,000
luminous-transmittance, and abrasion-
resistance properties of the primary lens
system material for full-facepiece respiratory
protective devices (RPD).
RCT-CBRN-APR-STP-0350--Determination of full 7,000
facepiece, tight-fitting, negative-pressure,
air-purifying respirator (APR) performance
during dynamic testing against the chemical
agent vapor sarin (GB)--qualifier live agent
testing (QLAT) only. RCT-CBRN-APR-STP-0350--remainder live agent 6,000
testing (RLAT). RCT-CBRN-APR-STP-0351--Determination of full- 7,000
facepiece, tight-fitting, negative-pressure,
air-purifying respirator (APR) performance
during dynamic testing against chemical agent
distilled sulfur mustard (HD) vapor and liquid
CBRN--qualifier live agent testing (QLAT) only. RCT-CBRN-APR-STP-0351--remainder live agent 6,000
testing (RLAT). RCT-CBRN-APR-STP-0350 and RCT-CBRN-APR-STP- 600
0351--aerosol process TDA-99M.TEB-CBRN-APR-STP-0352--Determination of 20,000
laboratory respirator protection level (LRPL)
values for CBRN self-contained breathing
apparatus (SCBA) facepieces or CBRN air-
purifying respirator (APR)--LRPL.TEB-CBRN-APR-STP-0352--partial laboratory 16,000
respirator protection level (LRPL) (in cases
where failure occurs with less than 50% of
subjects tested).* TEB-CBRN-APR-STP-0353--Weight and diameter... 200CET-APRS-STP-CBRN-0401--Determination of CBRN 1,000
organic vapor (cyclohexane) service-life test,
air-purifying escape respirators.CET-APRS-STP-CBRN-0402--Determination of CBRN 2,400
acid gases (cyanogen chloride) service-life
test, air-purifying escape respirators.CET-APRS-STP-CBRN-0403--Determination of CBRN 2,400
acid gases (hydrogen cyanide) service-life
test, air-purifying escape respirators.CET-APRS-STP-CBRN-0404--Determination of CBRN 1,400
acid gases (phosgene) service-life test, air-
purifying escape respirators.CET-APRS-STP-CBRN-0405--Determination of CBRN 800
acid gases (hydrogen sulfide) service-life
test, air-purifying escape respirators.CET-APRS-STP-CBRN-0406--Determination of CBRN 800
acid gases (sulfur dioxide) service-life test,
air-purifying escape respirators.CET-APRS-STP-CBRN-0407--Determination of CBRN 1,000
base gases (ammonia) service-life test, air-
purifying escape respirators.CET-APRS-STP-CBRN-0408--Determination of CBRN 1,200
nitrogen oxide gases (nitrogen dioxide)
service-life test, air-purifying escape
respirators.CET-APRS-STP-CBRN-0409--Determination of CBRN 1,000
hydride gases (phosphine) service-life test,
air-purifying escape respirators.CET-APRS-STP-CBRN-0410--Determination of CBRN 1,000
formaldehyde service-life test, air-purifying
escape respirators.CET-APRS-STP-CBRN-0411--Laboratory durability 22,000
conditioning process for environmental,
transportation and rough handling use
conditions on chemical, biological,
radiological and nuclear (CBRN) (air-purifying
or self-contained) escape respirator--RDECOM
environmental conditioning.CET-APRS-STP-CBRN-0411--NPPTL environmental 20,000
conditioning.* CET-APRS-STP-CBRN-0414--Fogging............. 4,000* CET-APRS-STP-CBRN-0417--Flammability, heat 14,000
resistance. CET-APRS-STP-CBRN-0450--Determination of 7,000
chemical agent permeation and penetration
resistance performance against sarin (GB)
vapor of chemical, biological, radiological,
and nuclear (CBRN) air-purifying escape
respirator--qualifier live agent testing
(QLAT) only. CET-APRS-STP-CBRN-0450--remainder live agent 6,000
testing (RLAT). CET-APRS-STP-CBRN-0451--Determination of 7,000
chemical agent permeation and penetration
resistance performance against sulfur mustard
(HD) liquid and vapor of the chemical,
biological, radiological, and nuclear (CBRN)
air-purifying escape respirator--qualifier
live agent testing (QLAT) only. CET-APRS-STP-CBRN-0451--remainder live agent 6,000
testing (RLAT). CET-APRS-STP-CBRN-0450 and CET-APRS-STP-CBRN- 600
0451--aerosol process TDA-99M.TEB-CBRN-APR-STP-0452--Determination of 20,000
laboratory respirator protection level (LRPL)
values for CBRN air-purifying escape
respirator--LRPL.TEB-CBRN-APR-STP-0452--partial LRPL............ 16,000CET-APRS-STP-CBRN-0454--Determination of human 3,500
subject breathing gas (HSBG) concentrations
(carbon dioxide and oxygen) for chemical,
biological, radiological and nuclear (CBRN)
air-purifying escape respirator.* CET-APRS-STP-CBRN-0455--Human subject 6,000
breathing gas test.CET-APRS-STP-CBRN-0456--Determination of (\1\)
practical performance level for chemical,
biological, radiological and nuclear (CBRN)
(air-purifying or self-contained) escape
respirator.CET-APRS-STP-CBRN-0499--Determination of ( \1\)
donning effectiveness of chemical, biological,
radiological and nuclear (CBRN) (air-purifying
or self-contained) escape respirator.TEB-CBRN-STP-0501--Determination of CBRN 1,000
organic vapor (cyclohexane) service-life test,
tight-fitting powered air-purifying
respirators (PAPR).TEB-CBRN-STP-0502--Determination of CBRN acid 2,400
gases (cyanogen chloride) service-life test,
tight-fitting powered air-purifying
respirators (PAPR).TEB-CBRN-STP-0503--Determination of CBRN acid 2,400
gases (hydrogen cyanide) service-life test,
tight-fitting powered air-purifying
respirators (PAPR).TEB-CBRN-STP-0504--Determination of CBRN acid 1,400
gases (phosgene) service-life test, tight-
fitting powered air-purifying respirators
(PAPR).TEB-CBRN-STP-0505--Determination of CBRN acid 800
gases (hydrogen sulfide) service-life test,
tight-fitting powered air-purifying
respirators (PAPR).TEB-CBRN-STP-0506--Determination of CBRN acid 800
gases (sulfur dioxide) service-life test,
tight-fitting powered air-purifying
respirators (PAPR).
TEB-CBRN-STP-0507--Determination of CBRN base 1,000
gases (ammonia) service-life test, tight-
fitting powered air-purifying respirators
(PAPR).TEB-CBRN-STP-0508--Determination of CBRN 1,200
nitrogen oxide gases (nitrogen dioxide)
service-life test, tight-fitting powered air-
purifying respirators (PAPR).TEB-CBRN-STP-0509--Determination of CBRN 1,000
hydride gases (phosphine) service-life test,
tight-fitting powered air-purifying
respirators (PAPR).TEB-CBRN-STP-0510--Determination of CBRN 1,000
formaldehyde service-life test, tight-fitting
powered air-purifying respirators (PAPR).TEB-APR-STP-0511-CBRN--Determination of CBRN 1,000
organic vapor (cyclohexane) service-life test,
loose-fitting powered air-purifying
respirators (PAPR).TEB-APR-STP-0512-CBRN--Determination of CBRN 2,400
acid gases (cyanogen chloride) service-life
test, loose-fitting powered air-purifying
respirators (PAPR).TEB-APR-STP-0513-CBRN--Determination of CBRN 2,400
acid gases (hydrogen cyanide) service-life
test, loose-fitting powered air-purifying
respirators (PAPR).TEB-APR-STP-0514-CBRN--Determination of CBRN 1,400
acid gases (phosgene) service-life test, loose-
fitting powered air-purifying respirators
(PAPR).TEB-APR-0515-CBRN--Determination of CBRN acid 800
gases (hydrogen sulfide) service-life test,
loose-fitting powered air-purifying
respirators (PAPR).TEB-APR-STP-0516-CBRN--Determination of CBRN 800
acid gases (sulfur dioxide) service-life test,
loose-fitting powered air-purifying
respirators (PAPR).TEB-APR-STP-0517-CBRN--Determination of CBRN 1,000
base gases (ammonia) service-life test, loose-
fitting powered air-purifying respirators
(PAPR).TEB-APR-STP-0518-CBRN--Determination of CBRN 1,200
nitrogen oxide gases (nitrogen dioxide)
service-life test, loose-fitting powered air-
purifying respirators (PAPR).TEB-APR-STP-0519-CBRN--Determination of CBRN 1,000
hydride gases (phosphine) service-life test,
loose-fitting powered air-purifying
respirators (PAPR).TEB-APR-STP-0520-CBRN--Determination of CBRN 1,000
formaldehyde service-life test, loose-fitting
powered air-purifying respirators (PAPR).NPPTL-STP-CBRN-PAPR-0550--Determination of CBRN 7,000
powered air-purifying respirator (PAPR)
performance during dynamic testing against the
chemical agent vapor sarin (GB) chemical,
biological, radiological and nuclear (CBRN)
standard testing procedure (STP).NPPTL-STP-CBRN-PAPR-0551--Determination of 7,000
CBRN, powered air-purifying respirator (PAPR)
performance during dynamic testing against
chemical agent distilled sulfur mustard (HD)
vapor and distilled sulfur mustard (HD) liquid
chemical, biological, radiological, and
nuclear (CBRN) standard testing procedure
(STP).TEB-CBRN-APR-STP-0552--Determination of 20,000
laboratory respirator protection level (LRPL)
values for CBRN tight-fitting powered air-
purifying respirator (PAPR).TEB-CBRN-APR-STP-0553--Determination of 20,000
laboratory respiratory protection level (LRPL)
values for CBRN loose-fitting powered air-
purifying respirator (PAPR).------------------------------------------------------------------------
New and Unspecified Tests------------------------------------------------------------------------This category is to be used for new, on-going, (\2\)
tests which are developed between revisions of
the test fee schedule or for special, one-time
tests which are required for respirators with
unique features (per 42 CFR 84.63).------------------------------------------------------------------------* Draft test procedure in place, but final STP has not been published. Test is conducted by U.S. Army Research, Development and Engineering
Command Edgewood Chemical Biological Center (ECBC).\1\ No Fee, done as part of LRPL (TEB-CBRN-APR-STP-0452).\2\ $500/day + the actual cost of non-NPPTL staff (typically medical
staff and test subjects). [80 FR 3908, Jan. 26, 2015]