Code of Federal Regulations (alpha)

CFR /  Title 42  /  Part 84  /  Sec. 84.161 Man test for gases and vapors; Type B and Type

(a) The completely assembled respirator will be worn in a chamber containing 0.1 0.025 percent isoamyl acetate vapor, and the intake of the hose, and not more than 25 percent of the hose length will be located in isoamyl acetate-free air.

(b) The man in the isoamyl acetate atmosphere will draw his inspired air through the hose and connections by means of his lungs alone.