(a) Each general emergency alarm system fused switch and distribution panel must have a fixed nameplate on the outside of its cover that has a description of its function. The rating of fuses must also be shown on the outside of the cover of a fused switch.
(b) Each general alarm contact maker must be marked ``GENERAL ALARM'' in red letters on a corrosion-resistant plate or on a sign.
(c) A contact maker that operates only the general emergency alarm signal in crew quarters, machinery spaces, and work spaces must be marked ``CREW ALARM'' by the method described in paragraph (b) of this section.
(d) Each general emergency alarm signal must be marked ``GENERAL ALARM--WHEN EMERGENCY ALARM SIGNAL RINGS GO TO YOUR STATION'' in red letters at least \1/2\ inch high.
(e) Each general emergency alarm system distribution panel must have a directory attached to the inside of its cover giving the designation of each circuit, the area supplied by each circuit, and the rating of each circuit fuse. [CGD 74-125A, 47 FR 15272, Apr. 8, 1982, as amended by USCG-2004-18884, 69 FR 58348, Sept. 30, 2004]