CFR /  Title 46  /  Part 32  /  Sec. 32.56-60 Ventilation ducts--T/ALL.

(a) Each duct for ventilation of Category A machinery spaces that passes through accommodation, service, or control spaces must be:

(1) Constructed of steel and insulated to ``A-60'' Class; or

(2) Constructed of steel, fitted with an automatic fire damper at each boundary where it enters and leaves the Category A machinery space, and insulated to ``A-60'' Class for a distance of 5 meters (16.4 feet) beyond each machinery space boundary.

(b) Each duct for ventilation of accommodation, service, and control spaces that passes through Category A machinery spaces must be constructed of steel and be fitted with an automatic fire damper at each Category A machinery space boundary. Subpart 32.57_Structural Fire Protection for Tank Vessels Contracted for

On or After January 1, 1963