CFR /  Title 46  /  Part 64  /  Sec. 64.91 Relief valve for the cargo pump discharge.

The cargo pump discharge must have a relief valve that is--

(a) Fitted between the cargo pump discharge and the shut-off valve, with the relief valve discharge piped back to the cargo pump suction or returned to the tank; and

(b) Set at the maximum design pressure of the piping and discharge hose, or less.