Code of Federal Regulations (alpha)

CFR /  Title 49  /  Part 179  /  Sec. 179.101-1 Individual specification requirements.

In addition to Sec. 179.100, the individual specification requirements are as follows: --------------------------------------------------------------------------------------------------------------------------------------------------------

Minimum

Bursting plate Test Manway

DOT specification Insulation pressure thickness pressure cover Bottom outlet Bottom washout Reference (179.***)

(psig) (inches) (psig) thickness--------------------------------------------------------------------------------------------------------------------------------------------------------105A100ALW....................... Yes............. 500 5/8 100 \2\ 2 1/2 No.............. No.............105A200ALW....................... Yes............. 500 5/8 200 \2\ 2 1/2 No.............. No.............105A300ALW....................... Yes............. 750 5/8 300 \2\ 2 5/8 No.............. No.............105A100W......................... Yes............. 500 \3\ 9/16 100 2 1/4 No.............. No.............105A200W......................... Yes............. 500 \3\ 9/16 200 2 1/4 No.............. No.............105A300W......................... Yes............. 750 \1\ 11/16 300 \7\ 2 1/4 No.............. No.............105A400W......................... Yes............. 1,000 \1\ 11/16 400 \7\ 2 1/4 No.............. No.............105A500W......................... Yes............. 1,250 \1\ 11/16 500 2 1/4 No.............. No............. 102-1, 102-2105A600W......................... Yes............. 1,500 \1\ 11/16 600 2 1/4 No.............. No............. 102-4, 102-17109A100ALW....................... Optional........ 500 5/8 100 \2\ 2 1/2 No.............. Optional.......109A200ALW....................... Optional........ 500 5/8 200 \2\ 2 1/2 No.............. Optional.......109A300ALW....................... Optional........ 750 5/8 300 \2\ 2 5/8 No.............. Optional.......109A300W......................... Optional........ 500 \1\ 11/16 300 2 1/4 No.............. Optional.......112A200W......................... Optional \4\.... 500 \3 5\ 9/ 200 2 1/4 No.............. No.............

16112A340W......................... Optional \4\.... 850 \1\ 11/16 340 2 1/4 No.............. No.............112A400W......................... Optional \4\.... 1,000 \1\ 11/16 400 2 1/4 No.............. No.............112A500W......................... Optional \4\.... 1,250 \1\ 11/16 500 2 1/4 No.............. No.............114A340W......................... Optional \4\.... 850 \1\ 11/16 340 \6\ Optional........ Optional....... 103114A400W......................... Optional \4\.... 1,000 \1\ 11/16 400 \6\ Optional........ Optional....... 103120A200ALW....................... Yes............. 500 5/8 200 \2\ 2 1/2 Optional........ Optional....... 103120A100W......................... Yes............. 500 \3\ 9/16 100 2 1/4 Optional........ Optional....... 103120A200W......................... Yes............. 500 \3\ 9/16 200 2 1/4 Optional........ Optional....... 103120A300W......................... Yes............. 750 \1\ 11/16 300 2 1/4 Optional........ Optional....... 103120A400W......................... Yes............. 1,000 \1\ 11/16 400 2 1/4 Optional........ Optional....... 103120A500W......................... Yes............. 1,250 \1\ 11/16 500 2 1/4 Optional........ Optional....... 103--------------------------------------------------------------------------------------------------------------------------------------------------------\1\ When steel of 65,000 to 81,000 p.s.i. minimum tensile strength is used, the thickness of plates shall be not less than \5/8\ inch, and when steel of

81,000 p.s.i. minimum tensile strength is used, the minimum thickness of plate shall be not less than \9/16\ inch.\2\ When approved material other than aluminum alloys are used, the thickness shall be not less than 2\1/4\ inches.\3\ When steel of 65,000 p.s.i. minimum tensile strength is used, minimum thickness of plates shall be not less than \1/2\ inch.\4\ Tank cars not equipped with a thermal protection or an insulation system used for the transportation of a Class 2 (compressed gas) material must

have at least the upper two-thirds of the exterior of the tank, including manway nozzle and all appurtenances in contact with this area, finished with

a reflective coat of white paint.\5\ For inside diameter of 87 inches or less, the thickness of plates shall be not less than \1/2\ inch.\6\ See AAR Specifications for Tank Cars, appendix E, E4.01 (IBR, see Sec. 171.7 of this subchapter), and Sec. 179.103-2.\7\ When the use of nickel is required by the lading, the thickness shall not be less than two inches. [Amdt. 179-52, 61 FR 28679, June 5, 1996, as amended at 66 FR 45390, Aug. 28, 2001; 68 FR 75760, Dec. 31, 2003]