Code of Federal Regulations (alpha)

CFR /  Title 49  /  Part 192  /  Sec. 192.115 Temperature derating factor (T) for steel pipe.

The temperature derating factor to be used in the design formula in Sec. 192.105 is determined as follows: ------------------------------------------------------------------------

Temperature

Gas temperature in degrees Fahrenheit (Celsius) derating factor

(T)------------------------------------------------------------------------250 F (121 C) or less................................ 1.000300 F (149 C)........................................ 0.967350 F (177 C)........................................ 0.933400 F (204 C)........................................ 0.900450 F (232 C)........................................ 0.867------------------------------------------------------------------------ For intermediate gas temperatures, the derating factor is determined by interpolation. [35 FR 13257, Aug. 19, 1970, as amended by Amdt. 192-85, 63 FR 37502, July 13, 1998] Secs. 192.117-192.119 [Reserved]