(a) Requirements. An operator of a gathering line must follow the safety requirements of this part as prescribed by this section.
(b) Offshore lines. An operator of an offshore gathering line must comply with requirements of this part applicable to transmission lines, except the requirements in Sec. 192.150 and in subpart O of this part.
(c) Type A lines. An operator of a Type A regulated onshore gathering line must comply with the requirements of this part applicable to transmission lines, except the requirements in Sec. 192.150 and in subpart O of this part. However, an operator of a Type A regulated onshore gathering line in a Class 2 location may demonstrate compliance with subpart N by describing the processes it uses to determine the qualification of persons performing operations and maintenance tasks.
(d) Type B lines. An operator of a Type B regulated onshore gathering line must comply with the following requirements:
(1) If a line is new, replaced, relocated, or otherwise changed, the design, installation, construction, initial inspection, and initial testing must be in accordance with requirements of this part applicable to transmission lines;
(2) If the pipeline is metallic, control corrosion according to requirements of subpart I of this part applicable to transmission lines;
(3) Carry out a damage prevention program under Sec. 192.614;
(4) Establish a public education program under Sec. 192.616;
(5) Establish the MAOP of the line under Sec. 192.619; and
(6) Install and maintain line markers according to the requirements for transmission lines in Sec. 192.707.
(7) Conduct leakage surveys in accordance with Sec. 192.706 using leak detection equipment and promptly repair hazardous leaks that are discovered in accordance with Sec. 192.703(c).
(e) Compliance deadlines. An operator of a regulated onshore gathering line must comply with the following deadlines, as applicable.
(1) An operator of a new, replaced, relocated, or otherwise changed line must be in compliance with the applicable requirements of this section by the date the line goes into service, unless an exception in Sec. 192.13 applies.
(2) If a regulated onshore gathering line existing on April 14, 2006 was not previously subject to this part, an operator has until the date stated in the second column to comply with the applicable requirement for the line listed in the first column, unless the Administrator finds a later deadline is justified in a particular case: ------------------------------------------------------------------------
Requirement Compliance deadline------------------------------------------------------------------------Control corrosion according to Subpart I April 15, 2009.
requirements for transmission lines.Carry out a damage prevention program October 15, 2007.
under Sec. 192.614.Establish MAOP under Sec. 192.619........ October 15, 2007.
Install and maintain line markers under April 15, 2008.
Sec. 192.707.Establish a public education program under April 15, 2008.
Sec. 192.616.Other provisions of this part as required April 15, 2009.
by paragraph (c) of this section for Type
A lines.------------------------------------------------------------------------
(3) If, after April 14, 2006, a change in class location or increase in dwelling density causes an onshore gathering line to be a regulated onshore gathering line, the operator has 1 year for Type B lines and 2 years for Type A lines after the line becomes a regulated onshore gathering line to comply with this section. [Amdt. 192-102, 71 FR 13301, Mar. 15, 2006, as amended by Amdt. 192-120, 80 FR 12777, Mar. 11, 2015]